Page 2 - COPYRIGHT & TRADEMARKS; Specifications are subject to change without notice.; FCC STATEMENT; This device may not cause harmful interference.; CE Mark Warning
I COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used...
Page 3 - II; Related Document
II Related Document Related Document The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest product information, please visit the official website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware...
Page 4 - III
III Contents Contents Chapter 1 Introduction ———————————— 01 1.1 Product Overview .........................................01 1.2 Appearance .................................................01 Chapter 2 Installation ————————————— 06 2.1 Package Contents .........................................06 2....
Page 5 - L2 Managed Switch; Product Overview; Front Panel; The front panel of TL-SG3210 is shown as the following figure.
01 L2 Managed Switch Introduction ChaCter C Product Overview C1C TP-LINK JetStream L2 Managed Switch, designed for workgroups and departments, provides wire-speed performance and abundant layer 2 management features. It provides a variety of service features and multiple powerful functions with high...
Page 6 - The front panel of TL-SG3216 is shown as the following figure.
02 L2 Managed Switch LEDs LED Status Indication PWR On The switch is powered on. Off The switch is powered off or power supply is abnormal. Flashing Power supply is abnormal. SYS Flashing The switch works properly.On/Off The switch works improperly. 10/100/1000M On A device is linked to the correspo...
Page 7 - after being on for 60 seconds and the Speed LED will light up again.
03 L2 Managed Switch LED Status Indication 1000Mbps On A 1000Mbps device is connected to the corresponding port. Off A 10/100Mbps device or no device is connected to the corresponding port. Link/Act On A device is connected to the corresponding port, but no activity. Flashing Data is being transmitt...
Page 8 - Rear Panel; The rear panel of TL-SG3210 is shown as the following figure.
04 L2 Managed Switch LED Status Indication PoE Max On The remaining PoE power ≤ 7W. Flashing The remaining PoE power keeps ≤ 7W after this LED is on for 2 minutes. Off The remaining PoE power ≥ 7W. 10/100/1000 Mbps Green On The port is supplying power normally. Flashing The supply power exceeds the ...
Page 9 - Grounding Terminal; Please use the provided power cord.
05 L2 Managed Switch Grounding Terminal Power Socket Rear Panel of TL-SG3210 Figure 1-5 The rear panel of TL-SG3216/TL-SG3424/TL-SG3424P is shown as the following figure. Grounding Terminal Power Socket Rear Panel of TL-SG3216/TL-SG3424/TL-SG3424P Figure 1-6 Grounding Terminal The switch already com...
Page 10 - Package Contents; Safety Precautions; Keep the power off during the installation.; Site Requirements
06 L2 Managed Switch Installation ChaCter 1 Package Contents 11C Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Resource CD One Switch One Power Cord, One Console Cable and one Ground Cable This Installa...
Page 11 - Environment; Clearness; Dust the device regularly, and keep the indoor air clean.; Electromagnetic Interference
07 L2 Managed Switch Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantl...
Page 12 - C hapt e r 3; Installation Site; Installation Tools; Desktop Installation
08 L2 Managed Switch Ensure the rack and device are well earthed. ■ Make sure the power socket has a good contact with the ground. ■ Keep a reasonable cabling system and avoid induced lightning. ■ Use the signal SPD (Surge Protective Device1 when wiring outdoor. ■ Not e: F or det aile d lightning pr...
Page 13 - Rack Installation; Check the grounding and stability of the rack.; Bracket Installation; Please set 5~10cm gaps around the device for air circulation.
09 L2 Managed Switch Feet Bottom of the Device Notch Desktop Installation Figure 2-1 Rack Installation ■ To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: Check the grounding and stability of the rack. 1. Secure the supplied rack-mounting brackets...
Page 14 - Cabling Reasonably; please use a signal lightning arrester.; Requirements for Cabling Outdoors; Aerial cabling without safeguard is not allowed.; Requirements for Cabling Indoors
10 L2 Managed Switch Lightning Protection ChaCter 2 Cabling Reasonably 21C In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devi...
Page 16 - Connect to Ground; Connecting to the Grounding Bar; Connecting to the Ground via the Power Supply; Connecting to the Ground
12 L2 Managed Switch Connect to Ground 211 Connecting the device to ground is to quickly release the lightning over-voltage and over-current of the device, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. Th...
Page 17 - EquiCotential Bonding; Equipotential Bonding; at least. The shorter cable the better, and use a grounding; equipotential bonding cable; is not provided with our product. If needed,
13 L2 Managed Switch Note: The figure is to illustrate the application and principle. The power cord you get from ■ the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above.If you intend to connect the device to the ground...
Page 18 - Use Lightning Arrester; ground via a shorter ground cable.; Lightning Arrester Connection
14 L2 Managed Switch Lightning Protection Use Lightning Arrester 212 Power lightning arrester and signal lightning arrester are used for lighting protection. Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC power cord should be directly connected t...
Page 19 - Connection; Ethernet Port; Connecting the RJ45 Port; SFP Port; Inserting the SFP Module; Switching; page. For 100M module, please select 100MFD while
15 L2 Managed Switch Connection Connection ChaCter 2 Ethernet Port 21C Connect the Ethernet ports of the switch to the network devices by RJ45 cable as the following figure shown. RJ45 Cable RJ45 Port Connecting the RJ45 Port Figure 4-1 SFP Port 211 Connect the SFP port to a SFP module. For TL-SG321...
Page 20 - Connecting the Console Port; Verify Installation
16 L2 Managed Switch Console Port 212 CLI (Command Line Interface1 enables you to manage the switch, thus you can load the CLI after connecting the PCs or Terminals to the console port on the switch via the provided cable. Connect the console port of the device with your computer by the console cabl...
Page 21 - Connecting to Power Supply; Initialization; The Power LED indicator will light on all the time.
17 L2 Managed Switch Connecting to Power Supply Figure 4-4 Note: The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. Initializati...
Page 22 - Configure the Switch via GUI; Web Browser; Then click the Login button or press the Enter key.; Login
18 L2 Managed Switch Configuration ChaCter 4 Configure the Switch via GUI 41C To access the GUI of the switch, open a web browser and t ype the default 1. management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Web Browser Figure 5-1 Note: To log on to th...
Page 23 - Main Page of the Switch; Configure the Switch Using CLI; Logon by a Console Port; Open Hyper Terminal
19 L2 Managed Switch Main Page of the Switch Figure 5-3 Configure the Switch Using CLI 411 You can log on to the switch and access the CLI by the following two methods: Log on to the switch by the console port on the Switch. ■ Log on to the switch remotely by a Telnet or SSH connection through an Et...
Page 24 - Connection Description
20 L2 Managed Switch The Connection Description Window will prompt as Figure 5-5. Enter a name into the 3. Name field and click OK. Connection Description Figure 5-5 Select the port to connect in Figure 5-6, and click OK. 4. Select the port to connect Figure 5-6 Configure the port selected in the st...
Page 25 - Port Settings; Logon by Telnet; Make sure the switch and the PC are in the same LAN.
21 L2 Managed Switch Port Settings Figure 5-7 Type the User name and Password in the Hyper Terminal window, the factory default 6. value for both of them is admin. The DOS prompt” TP-LINK>” will appear after pressing the Enter button as Figure 5-8 shown. It indicates that you can use the CLI now....
Page 26 - Open the Run window; Type cmd in the prompt Run window as Figure 5-10 and click OK.; Run Window
22 L2 Managed Switch Open the Run window Figure 5-9 Type cmd in the prompt Run window as Figure 5-10 and click OK. 3. Run Window Figure 5-10 Type telnet 192.168.0.1 in the command prompt shown as Figure 5-11, and press the 4. Enter button. Connecting to the Switch Figure 5-11 Configuration
Page 27 - Log in the Switch
23 L2 Managed Switch Type the User name and Password (the factory default value for both of them is 5. admin1 and press the Enter button, then you can use the CLI now, which is shown as Figure 5-12. Log in the Switch Figure 5-12 For detailed CLI configuration instructions, please refer to the CLI Re...
Page 28 - What could I do if I forgot the username and Cassword of the switch?; You are recommended to check the following items:; Why does the hyCer terminal disClay abnormally?; Please check as follows:
24 L2 Managed Switch Troubleshooting ACCendiA A What could I do if I forgot the username and Cassword of the switch? QC1 Connect the console port of the PC to the console port of the switch and open hyper 1. terminal. Power off and restart the switch. When you are prompted that “Press CTRL-B to ente...
Page 29 - Hardware SCecifications
25 L2 Managed Switch Hardware SCecifications ACCendiA B Item Content Standards IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX/100Base-FX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-X IEEE 802.3x Flow Control Transmission Medium 10Base-T: UTP/STP of Cat. 3 or above 100Base-TX: UTP/STP of Cat. 5...
Page 30 - Technical SuCCort
26 L2 Managed Switch Technical SuCCort ACCendiA C For more help, please go to: http://www.tp-link.com/en/support/faq ■ To download the latest Firmware, Driver, Utility and User Guide, go to: ■ http://www.tp-link.com/en/support/download For all other technical support, please contact us by using the ...