Page 2 - COPYRIGHT & TRADEMARKS; Specifications are subject to change without notice.; FCC STATEMENT; This device may not cause harmful interference.; CE Mark Warning
I COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used...
Page 3 - II; Related Document
II Related Document Related Document The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest product information, please visit the Official Website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware...
Page 4 - III; This Installation Guide is for:; Conventions
III Audience This Installation Guide is for: Network Engineer Network Administrator Conventions Due to the similarit y in the struc ture of the L2 Managed Switch series, in this Installation Guide we take TL-SG5428 as an example to illustrate Chapter 2 Installation, Chapter 3 Lightning Protection an...
Page 5 - IV
IV Contents Contents Chapter 1 Introduction ———————————— 01 1.1 Product Overview .........................................01 1.2 Appearance .................................................01 Chapter 2 Installation ————————————— 04 2.1 Package Contents .........................................04 2.2...
Page 6 - L2 Managed Switch; Product Overview; L2 Managed Switch integrates; ACCearance; Front Panel; The front panel of TL-SG5428 is shown as the following figure.
01 L2 Managed Switch Introduction ChaCter C Product Overview C1C TL-SG5428 and TL-SG5412F are Gigabit Ethernet switching products recently developed by TP-LINK. TL-SG5428 possesses 24 RJ45 ports and 4 SFP slots, while TL-SG5412F characterizes with 12 SFP slots and 4 R J45 por ts. The SFP slot enable...
Page 8 - Model; Rear Panel; Please use the provided power cord.
03 L2 Managed Switch Port Feature Model 10/100/1000Mbps RJ45 Port SFP Port Console Port TL-SG5428 24 4 1 TL-SG5412F 4 12 1 10/100/1000Mbps RJ45 Port Designed to connec t to the device with a bandwidth of 10Mbps, 100Mbps or 1000Mbps. For TL-SG5428, each 10/100/1000Mbps RJ45 port has a corresponding 1...
Page 9 - Package Contents; Safety Precautions; Keep the power off during the installation.; Site Requirements
04 L2 Managed Switch Installation ChaCter 1 Package Contents 11C Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Resource CD One Switch One Power Cord, One Console Cable and one Ground Cable This Installa...
Page 10 - Environment; Clearness; Dust the device regularly, and keep the indoor air clean.; Electromagnetic Interference; transmitting station.; Lightening Protection
05 L2 Managed Switch Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantl...
Page 11 - C hapt e r 3; Installation Site; Installation Tools; Desktop Installation
06 L2 Managed Switch protection measures should be taken. Ensure the rack and device are well earthed. ■ Make sure the power socket has a good contact with the ground. ■ Keep a reasonable cabling system and avoid induced lightning. ■ Use the signal SPD (Surge Protective Device1 when wiring outdoor. ...
Page 12 - Rack Installation; Check the grounding and stability of the rack.; Bracket Installation; Please set 5~10cm gaps around the device for air circulation.
07 L2 Managed Switch Turnover the device and attach the supplied rubber feet to the recessed areas on 3. the bottom at each corner of the device. TL -S G5 42 8 Feet Bottom of the Device Notch Desktop Installation Figure 2-1 Rack Installation ■ To install the device in an EIA standard-sized, 19-inch ...
Page 13 - Cabling Reasonably; please use a signal lightning arrester.; Requirements for Cabling Outdoors; Aerial cabling without safeguard is not allowed.; Requirements for Cabling Indoors
08 L2 Managed Switch Lightning Protection ChaCter 2 Cabling Reasonably 21C In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devi...
Page 15 - Connect to Ground; Connecting to the Grounding Bar; Connecting to the Ground via the Power Supply; Connecting to the Ground
10 L2 Managed Switch Connect to Ground 211 Connecting the device to ground is to quickly release the lightning over-voltage and over-current of the device, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. Th...
Page 16 - EquiCotential Bonding; Equipotential Bonding; at least. The shorter cable the better, and use a grounding; equipotential bonding cable; is not provided with our product. If needed,
11 L2 Managed Switch Note: The figure is to illustrate the application and principle. The power cord you get from ■ the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above.If you intend to connect the device to the ground...
Page 17 - ground via a shorter ground cable.; Lightning Arrester Connection; Use Lightning Arrester; is not appropriate for SFP ports
12 L2 Managed Switch Use Lightning Arrester 212 Power lightning arrester and signal lightning arrester are used for lighting protection. Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC power cord should be directly connected to the device, please ...
Page 18 - Connection; Ethernet Port; Connecting the RJ45 Port; SFP Port; Inserting the SFP Module
13 L2 Managed Switch Connection Connection ChaCter 2 Ethernet Port 21C Connect the Ethernet ports of the Switch to the network devices by RJ45 cable as the following figure shown. TL-SG5428 RJ45 Cable RJ45 Port Connecting the RJ45 Port Figure 4-1 SFP Port 211 Connect the SFP port to a SFP module. Fo...
Page 19 - Optical fiber; SFP module; SFP module. For detailed information, please refer to; Chapter 3 Lightning Protection
14 L2 Managed Switch Connection Optical fiber Optical fiber can be used as a medium for telecommunication and computer networking. It is especially advantageous for long-distance communications, because light propagates through the fiber with much less attenuation compared to electrical cables. For ...
Page 20 - Console Port; Connecting the Console Port; Verify Installation
15 L2 Managed Switch Console Port 212 CLI (Command Line Interface1 enables you to manage the Switch, thus you can load the CLI after connecting the PCs or Terminals to the console port on the Switch via the provided cable. Connect the console port of the device with your computer by the console cabl...
Page 21 - Connecting to Power Supply; Initialization; The PWR LED indicator will light on all the time.
16 L2 Managed Switch Connecting to Power Supply Figure 4-5 Note: The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. Initializati...
Page 22 - Configure the Switch via GUI; Web Browser; Then click the Login button or press the Enter key.; Login
17 L2 Managed Switch Configuration ChaCter 4 Configure the Switch via GUI 41C To access the GUI of the Switch, open a web browser and t ype the default 1. management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Web Browser Figure 5-1 Note: To log on to th...
Page 23 - Configure the Switch Using CLI; Logon by a Console Port; Open Hyper Terminal
18 L2 Managed Switch Configure the Switch Using CLI 411 You can log on to the Switch and access the CLI by the following two methods: Log on to the Switch by the console port on the Switch. ■ Log on to the Switch remotely by a Telnet or SSH connection through an Ethernet ■ port. Logon by a Console P...
Page 24 - Select the port to connect
19 L2 Managed Switch Select the port to connect Figure 5-6 Configure the port selected in the step above as the following Figure 5-7 shown. 5. Configure Bits per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, Flow control as None, and then click OK. Port Settings Figure 5-7 Type th...
Page 25 - Logon by Telnet; Make sure the switch and the PC are in the same LAN.; Open the Run window; Type cmd in the prompt Run window as Figure 5-10 and click OK.; Run Window
20 L2 Managed Switch Logon by Telnet ■ To log on to the switch by a Telnet connection, please take the following steps: Make sure the switch and the PC are in the same LAN. 1. Click Start 2. → Run to open the Run window. Open the Run window Figure 5-9 Type cmd in the prompt Run window as Figure 5-10...
Page 26 - Log in the Switch
21 L2 Managed Switch Type the User name and Password (the factory default value for both of them is 5. admin1 and press the Enter button, then you can use the CLI now, which is shown as Figure 5-12. Log in the Switch Figure 5-12 For detailed CLI configuration instructions, please refer to the CLI Re...
Page 27 - What could I do if I forgot the username and Cassword of the Switch?; You are recommended to check the following items:; Why does the hyCer terminal disClay abnormally?; Please check as follows:
22 L2 Managed Switch Troubleshooting ACCendiA A What could I do if I forgot the username and Cassword of the Switch? QC1 Connect the console port of the PC to the console port of the Switch and open hyper 1. terminal. Power off and restart the Switch. When you are prompted that “Press CTRL-B to ente...
Page 28 - Hardware SCecifications
23 L2 Managed Switch Hardware SCecifications ACCendiA B Item Content Standards IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3z 1000Base-X IEEE 802.3x Flow Control Transmission Medium 10Base-T: UTP/STP of Cat. 3 or above 100Base-TX: UTP/STP of Cat. 5 or above 1000Base-T...
Page 29 - Technical SuCCort
24 L2 Managed Switch Technical SuCCort ACCendiA C For more help, please go to: ■ http://www.tp-link.com/en/support/faq To download the latest Firmware, Driver, Utility and User Guide, go to: ■ http://www.tp-link.com/en/support/download For all other technical support, please contact us by using the ...