Page 2 - TABLE OF CONTENTS; Please read and understand these; Millivolt; INTRODUCTION; Approved Vent Components; Manufactured Home Requirements; PACKAGING; WARNING; GENERAL INFORMATION; Installation and repair should be per-; The use of other
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Packaging ......................................... Page 2Introduction ...................................... Page 2General Information .......................... Page 2New York City Approval ..................... Page 3Requirement...
Page 3 - greater; by closing their; less than; Table 7; show the appliances' gas; the electronic gas control valve.; Manifold Pressure Tap
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 New York City, New York (MEA) Installation of these fi replaces are approved for installation in New York City in the US state of New York. These appliances and their individual shut-off valves must be disconnected from the gas supply piping system ...
Page 4 - Requirements for the Commonwealth of Massachusetts; “GAS VENT DIRECTLY
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Note: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwel...
Page 5 - SAFETY & WARNIING INFORMATION
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 WARNING If the information in this manual is not follwed exactly, a fi re or explosion may result causing prop-erty damage, personal injury or loss of life. SAFETY & WARNIING INFORMATION WARNING This appliance is only for use with the type of ga...
Page 6 - Do; Figure 9; Figure 4; Typical Locations
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under...
Page 7 - VENT TERMINATION CLEARANCES; Figure 5; Horizontal Vent Termination Clearances; Figure 6; Side Elevation View; Horizontal Vent Termination Clearances; • Manufactured Home Construction and; CAUTIONS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Termination Heights For Vents Above Flat Or Sloped Roofs Ref. NFPA 54 / ANSI Z223.1, 7.6 Roof Pitch * Feet * Meters Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0....
Page 8 - EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Minimum Clearances
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C See Item D in the Text Below. Center Line of Termination Exterior Wall Horizontal Termination Ventilated Soffi t...
Page 9 - MINIMUM CLEARANCES TO COMBUSTIBLES; Table 8; for clearance
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Combustible materials may project beyond the sides of the fi re-place opening as long as they are kept within the shaded areas illustrated here. Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used...
Page 10 - TYPICAL INSTALLATION SEQUENCE; Pressure Relief Plates; STEP 2. ROUTING GAS LINE; on; DETAILED INSTALLATION STEPS; Remove the cardboard from; See; DO NOT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Also see Figure 14. 6 1/2" (152 mm) 3" (76 mm) Figure 13 - ROUTE GAS LINE Right Side Front Corner of Fire-place Framing Continued on Page 12. TYPICAL INSTALLATION SEQUENCE The typical sequence of installation follows, however, each installa...
Page 11 - FIREPLACE SPECIFICATIONS; Vent Size; Notes; Frame ceiling opening; Top View; Right Side View; positioned in louvered
11 FIREPLACE SPECIFICATIONS Vent Size Co-axial DV Vent Size 4-1/2" Inner 7-1/2" Outer Notes * The Steady State Effi ciency numbers based on maximum vent confi guration. Due to Lennox' ongoing commitment to quality, all specifi cations, ratings and dimensions are subject to change without not...
Page 12 - Proper Sizing of Gas Line; Table 9; FIREPLACE FRAMING SPECIFICATIONS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 C Back wall of chase/enclosure (including any finishing materials) a 7 1/4 (184) b D Inches (millimeters) F A B E Note- SSDV-3530 Models -• Venting requirements for rear vent applications in corner installations, the horizontal vent length “a” to “...
Page 13 - or rear fl ue outlet as shown in; Step 3. INSTALL THE VENT SYSTEM
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Figure 16 Figure 17 Select Venting System - Horizontal or Vertical With the appliance secured in framing, de-termine vent routing and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exteri...
Page 14 - and their associated; Model
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 14 SV4.5CGV-1 Termination SV4.5FA ORSV4.5FB FlashingAND SV4.5SCSTORM COLLAR SV4.5VF Firestop/Spacer SV4.5L6/12/24/36/48Vent Sections 40' Max (12.2 M) 1" (25.4 mm)MinimumClearance toCombustibles When using Secure Flex use Firestop/Spacer SF4.5VF...
Page 15 - Dimple; An elbow may also be attached to the; Blocking
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 To add another vent component to a length of vent run, align the dimpled end over the inclined channel end of the previously installed section, adjusting the radial alignment until the four lock-ing dimples are aligned with the inlets of the four i...
Page 17 - A Vent Restrictor, as shown in; Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; Secure Vent
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 V H H V V1 Figure 26 - Top Vent - STRAIGHT Notes: • It is very important that the horizontal/in- clined run be maintained in a straight (no dips) and recommended to be in a slightly elevated plane, in a direction away from the fi replace of 1/4"...
Page 18 - ) horizontal run up to; Top Vent - THREE ELBOWS; and their associated Horizontal Vent
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 H1 V V1 H V H1 H V1 Ceiling Firestop / Spacer (SV4.5VF) Ceiling Firestop / Spacer (SV4.5VF) Wall Firestop/ Spacer (SV4.5HF) Wall Firestop/ Spacer (SV4.5HF) Ceiling Firestop / Spacer (SV4.5VF) Example: If 20 feet total (H+H 1 ) horizontal vent run i...
Page 19 - TYPICAL HORIZONTAL VENT INSTALLATION; refer to Figure
19 Horizontal / Inclined Run Support Brackets Building Support Framing SV4.5E90 Elbow Ceiling Firestop / Spacer SV4.5VF When Using Secure Flex, Use Firestop / Spacer SF4.5VF Fireplace SV4.5L6/12/24/36/48 Vent Sections Vertical Rise SV4.5HT-2 Termination Shown Support Bracket Spacing Every 5 ft (1.52...
Page 20 - Step B; IMPORTANT; Termination Guard; Page 33. This can be
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 SV4.5 HT-2 Termination SV4.5 HT-2 Termination Horizontal terminations have been designed to perform in a wide range of weather condi-tions. Our terminations meet or exceed industry standards. When selecting the locations of your horizontal terminat...
Page 21 - Wall; components (rigid vent pipe and terminal) are shown in; HORIZONTAL VENT FIGURES/TABLES; Termination Kit Only
21 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. H H = 28 in. (711 mm) Maximum. 7 in. (178 mm) When using Secure Flex, use Firestop/Spacer SF4.5HF Wall Firestop/Spacer (SV4.5HF) H V Wall Firestop/Spacer (SV4.5HF) When using Secure Flex, use Firestop/Spacer SF4.5VF. Ceiling Firestop/Spacer (SV4.5V...
Page 22 - to a maximum horizontal run of 20 feet.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 22 H1 V H Wall Firestop/Spacer (SV4.5HF) Ceiling Firestop/Spacer (SV4.5VF) When using Secure Flex, use Firestop/Spacer SF4.5HF. When using Secure Flex, use Firestop/Spacer SF4.5VF. V H H1 Wall Firestop/Spacer (SV4.5HF) Wall Firestop/Spacer (SV4.5HF) W...
Page 23 - horizontal run of 20 feet.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 23 V H2 H1 H Wall Firestop/Spacer (SV4.5HF) Ceiling Firestop/Spacer (SV4.5VF) When using Secure Flex, use Firestop/Spacer SF4.5VF. When using Secure Flex, use Firestop/Spacer SF4.5HF. V H H1 V1 Wall Firestop/Spacer (SV4.5HF) Ceiling Firestop/Spacer (S...
Page 24 - SECURE FLEX; Secure Flex
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 24 D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a fi restop / spacer is required: use the SF4.5 VF fi restop / spacer for ceilings and the SF4.5 HF fi restop / spacer for walls. See the appropria...
Page 25 - Step 4. FIELD WIRING; A. SIT and Honeywell Millivolt Wiring; Figures; WIRING - OPTIONAL FORCED AIR; B. Electronic Wiring
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 25 CAUTION Ensure that wires are positioned away from hot surfaces and sharp edges. CAUTION Do not connect the optional wall switch for burner operation to a 120 Volt AC power supply. CAUTION Label all wires prior to disconnection when servicing contr...
Page 26 - Schematic Representation Only; CAUTION; Step 6. CONNECTING GAS LINE; Figure; Gas Flex Line Connector; GAS CONNECTION
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 26 Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits Schematic Representation Only Relay Module C/W FBK-250 only. Plug blower into J-Box receptacle for FBK-100 or FBK-200 application. See View...
Page 27 - Piezo
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 27 Replace logs if removed for pilot inspection. To light the burner; turn “ON” the remote wall switch and rotate the gas valve control knob counterclockwise to the “ON” position. Figure 50 Proper Pilot Flame Appearance Thermocouple Thermopile PilotNo...
Page 28 - Glowing Embers; Bag of Glowing; Remove the front glass enclosure panel; Electronic Appliance Checkout
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 28 REFERENCE Firebox Accessories / Parts Cat. No. Model No. Description 88L53 FGE Bag of Glowing Embers(1 oz. rockwool) 80L42 FDVS Bag of Decorative Volcanic Stone Table 13 Glowing Embers Bag of Glowing Embers (rockwool) Separate into Quarter Size (se...
Page 29 - LOG SET
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 53 29 MODEL SSDV-3530Log Placement Instructions Install the Embers, Volcanic Stone and Logs in the order shown here (1 through 5) and per the instructions on Page 28 . LOG SET Catalog Number H3367 * Item Description A Log, Rear B Log, Top Left ...
Page 30 - Place Embers and Volcanic Stone as Shown
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 54 30 LOG SET Catalog Number H3368 * Item Description A Log, Rear B Log, Top Left C Log, Center D Log, Top Right * Item "letters" above correspond to photos Install the Embers, Volcanic Stone and Logs in the order shown here (1 through ...
Page 31 - Reinstalling Control
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 9. INSTALLING THE GLASS DOOR WARNING Air shutter adjustment should only be performed by a qualifi ed profes-sional service technician. WARNING Ensure front glass panels are in place and sealed during adjust-ment. Air Shutter Adjustment Guidelines...
Page 32 - Main Burner Factory Air Shutter; HOOD INSTALLATION; Page 6; for Cold Climate Insulation; Burner Air Shutter Adjustment Procedure
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 32 Figure 56 Burner Flame Appearance Models - SSDV-3530 & SSDV-4045 Series Burner Air Shutter Adjustment Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Natural Gas Propane Gas SSDVT-3530 1/4 (6.35 mm) 1/2 (12.7 mm) SSD...
Page 33 - INSTALLATION ACCESSORIES
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 33 Item Cat. No. Model Description 1 H1968 SV4.5HT-2 Horizontal Square Termination With Firestop / spacer (H2246) & Adapter (74L61) 2a H2152 SV4.5CGV-1 Vertical Termination Cap 2b H4687 SV4.5CTS Chase Top Termination Square 2b H4716 SV4.5CTS-B Cha...
Page 34 - Item; Open Top Shroud Kits; Closed Top Shroud Termination Kits
34 INSTALLATION ACCESSORIES NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without fl ex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) 18 77L88 SFKIT18S Flex Square Term. (with 18 inc...
Page 35 - GAS CONVERSION KITS; * All compressed fl ex vents can be expanded up to two times.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 35 (ref. Form # 750,204M) GAS CONVERSION KITS Millivolt SIT Systems Propane to Natural Gas Conversion Kits Models Cat. No. SSDVT/R-3530 85L66 SSDVT/R-4035 85L67 Millivolt HONEYWELL Systems Natural Gas To Propane Gas Conversion Kits Models Cat. No. SSD...
Page 36 - NAT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 36 Note - Use extra care not to engage the orifi ce strip with the 7/16" open end wrench (contacting the orifi ce strip could cause strip distortion rendering the pilot inoperative). Also avoid wrench contact to any of the other pilot parts. Use a...
Page 37 - . Reassemble all removed components; Spring; Inlet Pressure Test Port
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 37 Figure 65 Note: If the Igniter is damaged, a replacement kit is available - order Catalog Number 87L54. RetainingClip IgnitorAssembly PilotAssembly Pilot Orifice Flare Nut Figure 66 Step 9 . Reassemble all removed components by reversing the proced...
Page 38 - NOTES
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 38 NOTES