Page 2 - TABLE OF CONTENTS; Please read and understand these; Millivolt; WARNING
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New Yor...
Page 3 - must be disconnected; greater; by closing their; less than; Table 6
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa) . These appliances must be isolated from the gas sup...
Page 4 - CHUSETTS REQUIREMENTS; Massachusetts Horizontal Vent Re-; Flame Height
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NEW YORK CITY, NY AND MASSA- CHUSETTS REQUIREMENTS These appliances are approved for instal- lation in the following USA locations listed in the following: Massachusetts - Installation of these fireplaces are ap- proved for installation in the US st...
Page 5 - see; Do
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. COLD CLIMATE INSULATION For cold climate installations, seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under...
Page 6 - Figure 4; Typical Locations; This appliance may be installed in an after-; CAUTIONS
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 4 - Typical Locations MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an after- market permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé da...
Page 7 - VENT TERMINATION CLEARANCES; These instructions should be used as a guide-; Figure 5; Horizontal Vent Termination Clearances; Termination Heights For Vents; Side Elevation View; Figure 6
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. The vent / air intake termination clearances above the high side of an angled roof is as shown in the following chart: 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING ...
Page 8 - Figure 7; EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 7 V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent Termination V D V 3 ft. 3 ft. A A A = 9 in U.S. = 12 in Canada V L B J X V A G Inside Corner Detail B C C ...
Page 9 - MINIMUM CLEARANCES TO COMBUSTIBLES; Table 8
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Combustible materials may project beyond the sides of the fire- place opening as long as they are kept within the shaded areas illustrated here. Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used...
Page 10 - TYPICAL INSTALLATION SEQUENCE; Pressure Relief Plates; STEP 2. ROUTING GAS LINE; Control Compartment Access / Louver Panel
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Also see Figure 14. 6 1/2" (152 mm) 3" (76 mm) Figure 13 - ROUTE GAS LINE Right Side Front Corner of Fire- place Framing Continued on Page 12. TYPICAL INSTALLATION SEQUENCE The typical sequence of installation follows, however, each install...
Page 11 - FIREPLACE SPECIFICATIONS; Vent Size; Vertical Venting Through the Ceiling:; Frame ceiling opening; Top View; Notes; required framing depth dimension
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FIREPLACE SPECIFICATIONS Vent Size Co-axial DV Vent Size 4-1/2" Inner 7-1/2" Outer Vertical Venting Through the Ceiling: Frame ceiling opening - Use a plumb line from the ceiling above the appli- ance to locate center of the vertical run. C...
Page 12 - Table 9; Proper Sizing of Gas Line
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 15 Corner Framing with Square Termination (SV4.5HT-2) Schedule 40 / Black Iron Pipe Inside Diameter (Inches) Schedule 40 Pipe Length (feet) Natural Gas Propane Gas 0-10 1/2 3/8 10-40 1/2 1/2 40-100 1/2 1/2 100-150 3/4 1/2 150-200 3/4 1/2 Tab...
Page 13 - Approved Vent Components; on
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 16 Figure 17 Select Venting System - Horizontal or Vertical With the appliance secured in framing, de- termine vent routing and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exter...
Page 14 - Model
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. SV4.5CGV-1 Termination SV4.5FA OR SV4.5FB Flashing AND SV4.5SC STORM COLLAR � SV4.5VF Firestop/Spacer SV4.5L6/12/24/36/48 Vent Sections 40' Max (12.2 M) 1" (25.4 mm) Minimum Clearance to Combustibles � When using Secure Flex use Firestop/Spacer...
Page 15 - Pages
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. To add another vent component to a length of vent run, align the dimpled end over the inclined channel end of the previously installed section, adjusting the radial alignment until the four lock- ing dimples are aligned with the inlets of the four ...
Page 17 - Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; rate sections of concentric flexible
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. V H H V V1 Figure 26 - Top Vent - STRAIGHT Notes: • It is very important that the horizontal/in- clined run be maintained in a straight (no dips) and recommended to be in a slightly elevated plane, in a direction away from the fireplace of 1/4"...
Page 18 - Top Vent - THREE ELBOWS; Figure 31, and Figures 34 to 40 on Pages
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. H1 V V1 H V H1 H V1 u Ceiling Firestop / Spacer (SV4.5VF) u Ceiling Firestop / Spacer (SV4.5VF) v Wall Firestop/ Spacer (SV4.5HF) v Wall Firestop/ Spacer (SV4.5HF) u Ceiling Firestop / Spacer (SV4.5VF) Example: If 20 feet total (H+H 1 ) horizontal ...
Page 19 - TYPICAL HORIZONTAL VENT INSTALLATION; refer to Figure
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Horizontal / Inclined Run Support Brackets Building Support Framing SV4.5E90 Elbow Ceiling u Firestop / Spacer SV4.5VF u When Using Secure Flex, Use Firestop / Spacer SF4.5VF Fireplace SV4.5L6/12/24/36/48 Vent Sections Vertical Rise SV4.5HT-2 Termi...
Page 20 - including the use of silicone caulking where required.; Step B; IMPORTANT; Termination Guard
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. SV4.5 HT-2 Termination SV4.5 HT-2 Termination Horizontal terminations have been designed to perform in a wide range of weather conditions. Our terminations meet or exceed industry standards. When selecting the locations of your horizontal terminati...
Page 21 - Wall; Under no circumstances, may separate sections of; HORIZONTAL VENT FIGURES/TABLES; zontal vent run is needed, then; Termination Kit Only
21 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. H H = 28 in. (711 mm) Maximum. 7 in. (178 mm) � When using Secure Flex, use Firestop/Spacer SF4.5HF � Wall Firestop/Spacer (SV4.5HF) H V � Wall Firestop/Spacer (SV4.5HF) � When using Secure Flex, use Firestop/Spacer SF4.5VF. � Ceiling Firestop/Spac...
Page 22 - See Table 12 on Page 21 as an aid in venting component
22 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. H1 V H � Wall Firestop/Spacer (SV4.5HF) � Ceiling Firestop/Spacer (SV4.5VF) � When using Secure Flex, use Firestop/Spacer SF4.5HF. � When using Secure Flex, use Firestop/Spacer SF4.5VF. V H H1 � Wall Firestop/Spacer (SV4.5HF) � Wall Firestop/Spacer...
Page 24 - SECuRE FLEX
24 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropriate ...
Page 25 - Step 4. FIELD WIRING; A. SIT and Honeywell Millivolt Wiring; WIRING - OPTIONAL FORCED AIR; Caution: do not; B. Electronic Wiring; See
25 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CAUTION Ensure that wires are positioned away from hot surfaces and sharp edges. CAUTION Do not connect the optional wall switch for burner operation to a 120 Volt AC power supply. CAUTION Label all wires prior to disconnection when servicing contr...
Page 26 - Schematic Representation Only; CAUTION; ground screw located on the outlet box. See; Step 6. CONNECTING GAS LINE; Figure; Secure all joints tightly using appropriate; Gas; Gas Flex Line Connector; GAS CONNECTION
26 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits Schematic Representation Only Relay Module C/W FBK-250 only. Plug blower into J-Box receptacle for FBK-100 or FBK-200 application. See View...
Page 27 - TEST ALL CONNECTIONS FOR GAS LEAKS; Never use an open flame to; CONTROL COMPARTMENT ACCESS/; Piezo; TION; can be found in the control compartment; SIT and Honeywell Millivolt Appliance; Lower Control
27 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 49 Thermocouple Thermopile Pilot Nozzels SIT MILLIVOLT PILOT ASSEMBLY Igniter Rod Hood Proper Pilot Flame Appearance 3/8" Min. (9 mm) TEST ALL CONNECTIONS FOR GAS LEAKS (FACTORY AND FIELD): WARNING Never use an open flame to check for le...
Page 28 - Proper twig placement is critical in the
28 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 51 3/8" to 1/2" (9 -13 mm) Hot Surface Igniter Proper Flame Adjustment Pilot Nozzels ELECTRONIC PILOT ASSEMBLY Proper Pilot Flame Appearance Electronic Appliance Checkout To light the burner, turn ‘ON’ the optional remote wall switch...
Page 29 - REFERENCE; Bag of Glowing; Glowing Embers
29 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING The size and position of the log set was engineered to give the appli- ance a safe, reliable and attrac- tive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combus...
Page 30 - Step 9. INSTALLING THE GLASS DOOR; Ensure front glass panels are in; Reinstalling Control
30 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 9. INSTALLING THE GLASS DOOR WARNING Air shutter adjustment should only be performed by a qualified profes- sional service technician. WARNING Ensure front glass panels are in place and sealed during adjust- ment. Air Shutter Adjustment Guidel...
Page 31 - Main Burner Factory Air Shutter; Burner Air Shutter Adjustment; HOOD INSTALLATION; Page 6; for Cold Climate Insulation; The air shutter door and nearby appliance surfaces are; Burner Air Shutter Adjustment Procedure
31 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Burner Flame Appearance Models - SSDV-3328 Series Figure 55 Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Natural Gas Propane Gas SSDVT-3328 SSDVR-3328 1/32 (0.826 mm) 5/16 (7.94 mm) Figure 56 Combustible Finished Wall...
Page 32 - INSTALLATION ACCESSORIES
32 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Item Cat. No. Model Description 1 H1968 SV4.5HT-2 Horizontal Square Termination With Firestop/spacer (H2246) & Adapter (74L61) 2a H2152 SV4.5CGV-1 Vertical Termination Cap 2b H4687 SV4.5CTS Chase Top Termination Square 2b H4716 SV4.5CTS-B Chase...
Page 33 - Item; Open Top Shroud Kits; Closed Top Shroud Termination Kits
33 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTALLATION ACCESSORIES NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Item Cat. No. Model Description 18 H1969 SF4.5HT-2 Horizontal Square Termination (without flex) 18 77L87 SFKIT12S Flex Square Term. (with 12 inch [305 mm] * compressed flex) ...
Page 34 - GAS CONVERSION KITS; * All compressed flex vents can be expanded up to two times.
34 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. GAS CONVERSION KITS Millivolt SIT Systems Propane to Natural Gas Conversion Kits Models Cat. No. SSDVT/R-3328 H1595 Millivolt HONEYWELL Systems Natural Gas To Propane Gas Conversion Kits Models Cat. No. SSDVT/R-3328 26M51 Electronic HONEYWELL Syste...
Page 35 - NA; La conversion devra être effectuée
35 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Note - use extra care not to engage the orifice strip with the 7/16" open end wrench (contacting the orifice strip could cause strip distortion rendering the pilot inoperative). Also avoid wrench contact to any of the other pilot parts. Use a 7...