Page 2 - Complete this page for quick reference when service is required:; Date of Installation:; Information found on the data label:; Voltage
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity: A E May, 2003...
Page 3 - Table of Contents
Model C707 Table of Contents Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 2 To the Operator 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 3 Safety 5 . ....
Page 5 - Installer Safety
1 Model C707 To the Installer 081208 Section 1 To the Installer The following are general installation instructions. For complete installation details, please see the checkout card. Installer Safety In all areas of the world, equipment should be installed in accordance with existing local codes. Ple...
Page 7 - Beater Rotation; Refrigerant
3 Model C707 To the Installer 120702 Appliances that are permanently connected to fixed wiring and for which leakage currents may exceed 10 mA, particularly when disconnected or not used for long periods, or during initial installation, shall have protective devices such as a GFI, to protect against...
Page 8 - Section 2; Compressor Warranty Disclaimer
4 Model C707 To the Operator 080714 Section 2 To the Operator The Model C707 has been carefully engineered and manufactured to give you dependable operation. This unit, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products, it will require clea...
Page 11 - Section 4
7 Model C707 Operator Parts Identification 080715 Section 4 Operator Parts Identification Model C707 ITEM DESCRIPTION PART NO. 1 COVER-HOPPER COMPLETE 053809-1 2 PAN-DRIP 11-5/8 LONG 027503 3 PIN-RETAINING-HOPPER CVR 043934 4 PANEL-SIDE-LEFT 056082-SP3 5 STUD-NOSE CONE 055987 6 SHIELD-SPLASH 049203 ...
Page 12 - Model C707 Single Spout Door and Beater Assembly
8 Model C707 Operator Parts Identification 110630 Model C707 Single Spout Door and Beater Assembly ITEM DESCRIPTION PART NO. 1 DOOR A.-W/BAFFLE X56071-SER 2 HANDLE A.-DRAW-WELDED X56246 3 SCREW-ADJUSTMENT-5/16-24 056332 4 O-RING-1/4 OD X .070W 50 015872 5 PIN-HANDLE-SS 055819 6 PLUG-PRIME 028805 7 O...
Page 13 - Brushes
9 Model C707 Operator Parts Identification 110915 Brushes ITEM DESCRIPTION PART NO. 1 BLACK BRISTLE BRUSH 013071 2 DOUBLE END BRUSH 013072 3 WHITE BRISTLE BRUSH (1” x 2”) 013073 4 WHITE BRISTLE BRUSH (3” x 7”) 023316 ITEM DESCRIPTION PART NO. 5 BRUSH-- END-- DOOR SPOUT SS 039719 6 BRUSH-- SET LVB 05...
Page 14 - Section 5
10 Model C707 Important: To the Operator Section 5 Important: To the Operator ITEM DESCRIPTION 1 MIX LOW INDICATOR LIGHT 2 MIX OUT INDICATOR LIGHT 3 MIX REFRIGERATION KEY 4 STANDBY KEY 5 WASH KEY ITEM DESCRIPTION 6 AUTO KEY 7 RESET BUTTON -- BEATER MOTOR 8 POWER SWITCH (TOGGLE) 9 HOPPER TEMP. INDICA...
Page 16 - AUTO Key; Adjustable Draw Handle
12 Model C707 Important: To the Operator 060518 AUTO Key When the AUTO key is pressed, the light comes on. This indicates that the main refrigeration system has been activated. In the AUTO mode, the WASH or STANDBY functions are automatically cancelled. The MIX REF function is automatically locked i...
Page 17 - Feed Tube Assembly
13 Model C707 Important: To the Operator 050112 Feed Tube Assembly The feed tube assembly serves two purposes. One end of the tube has a hole and the other end does not. 1. Normal Operation During normal operation, the end of the feed tube with the hole is placed into the mix inlet hole. Every time ...
Page 18 - Section 6; Assembly
14 Model C707 Operating Procedures Section 6 Operating Procedures The C707 unit stores mix in a hopper. It has a 3.4 quart (3.2 liter) capacity freezing cylinder and a 20 quart (18.9 liter) mix hopper. This unit uses a feed tube to allow mix to flow into the freezing cylinder. We begin our instructi...
Page 22 - Sanitizing
18 Model C707 Operating Procedures 080715 Sanitizing Step 1 Prepare an approved 100 PPM sanitizing solution (examples: 2--1/2 gal. [9.5 liters] of Kay--5 R or 2 gal. [7.6 liters] of Stera--Sheen R ). USE WARM WA- TER AND FOLLOW THE MANUFACTURER’S SPECIFICATIONS. Step 2 Pour the sanitizing solution o...
Page 24 - Priming; Closing Procedure
20 Model C707 Operating Procedures Priming Step 1 Place an empty pail beneath the door spout and lower the draw handle. Be sure the prime plug is still in the UP position. Pour two gallons (7.6 liters) of fresh mix into the hopper and allow it to flow into the freezing cylinder. This will force out ...
Page 25 - Draining Product From the; Rinsing; Cleaning
21 Model C707 Operating Procedures 080908 Draining Product From the Freezing Cylinder Step 1 Press the AUTO key, cancelling compressor and beater motor operation. Press the MIX REF key, cancelling the mix hopper refrigeration system. Step 2 Remove the hopper cover and take it to the sink for cleanin...
Page 26 - Disassembly; Brush Cleaning
22 Model C707 Operating Procedures 110915 Disassembly Step 1 Be sure the power switch is in the OFF position. Make sure no lights are lit on the control panel. Step 2 Remove the handscrews, freezer door, beater, beater, scraper blades, and drive shaft from the freezing cylinder. Take these parts to ...
Page 27 - During Cleaning and Sanitizing; Troubleshooting Bacterial Count
23 Model C707 Important: Operator Checklist 080401 Section 7 Important: Operator Checklist During Cleaning and Sanitizing ALWAYS FOLLOW LOCAL HEALTH CODES. Cleaning and sanitizing schedules are governed by federal, state, or local regulatory agencies, and must be followed accordingly. If the unit ha...
Page 28 - Winter Storage
24 Model C707 Important: Operator Checklist 080401 j 6. If your machine is air cooled, check the condensers for accumulation of dirt and lint. Dirty condensers will reduce the efficiency and capacity of the machine. Condensers should be cleaned monthly with a soft brush. Never use screwdrivers or ot...
Page 29 - Section 8; PROBLEM
25 Model C707 Troubleshooting Guide Section 8 Troubleshooting Guide PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 1. No product is being dispensed with draw valve open and the machine in the AUTO mode. a. Freeze--up in mix inlet hole. a. Call service technician to adjust the mix hopper temperature. -- -- ...
Page 31 - Section 9
27 Model C707 Parts Replacement Schedule 110915 Section 9 Parts Replacement Schedule PART DESCRIPTION EVERY 3 MONTHS EVERY 6 MONTHS ANNUALLY Drive Shaft Seal X Scraper Blade X Freezer Door Gasket X Front Bearing X Draw Valve O--Ring X Prime Plug O--Ring X Feed Tube O--Ring X Air Orifice O--Ring X Wh...