Page 2 - Complete this page for quick reference when service is required:; Date of Installation:; Information found on the data label:; Voltage; Taylor Company
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Fax: E- mail: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity:...
Page 3 - Table of Contents
Table of Contents Model C300 Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 2 To the Operator 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 3 Safety 6 . ....
Page 4 - Table of Contents - Page 2; During Cleaning and Sanitizing
Table of Contents Model C300 Table of Contents - Page 2 Section 7 Important: Operator Checklist 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . During Cleaning and Sanitizing 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting Bacterial...
Page 5 - To the Installer; Section 1; Installer Safety; Note: All repairs must be performed by an; Site Preparation; NOT
1 Model C300 To the Installer 131210 Section 1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. Installer Safety In all areas of the world, equipment should b...
Page 6 - Water Cooled Refrigeration Units; to an open trap drain; Water Connections
2 Model C300 To the Installer Water Cooled Refrigeration Units (Water Cooled Units Only) On the back of the unit, two additional 3/8” (9.5 mm) F.P.T. water connections for condenser inlet and outlet have been provided for easy hook- up. 3/8” (9.5 mm) inside diameter water lines should be connected t...
Page 7 - Electrical Connections; Beater Rotation
3 Model C300 To the Installer 131210 Electrical Connections In the United States, this equipment is intended to be installed in accordance with the National Electrical Code (NEC), ANSI/NFPA 70- 1987. The purpose of the NEC code is the practical safeguarding of persons and property from hazards arisi...
Page 8 - Initial Freezing Cylinder Cleaning
4 Model C300 To the Installer 090219 Initial Freezing Cylinder Cleaning Due to the types of products used in FCB equipment, it is imperative that the freezing cylinder and the inlet tube be thoroughly brush cleaned, rinsed, and sanitized before running any product. Prepare a cleaning solution, using...
Page 9 - Compressor Warranty Disclaimer
5 Model C300 To the Operator 131210 Section 2 To the Operator The freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The Model C300, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products,...
Page 12 - Operator Parts Identification; Section 4
8 Model C300 Operator Parts Identification 090417 Section 4 Operator Parts Identification Figure 2 ITEM DESCRIPTION PART NO. 1 PANEL A.-SIDE-LEFT C300 X54676-SER 2 PANEL-REAR 054672 3 PANEL-SIDE-RIGHT 054671 4 DISPLAY-LIGHTED 054683-27 5 PANEL-FRONT-UPPER 054669 6 PANEL-FRONT-SHELL 054668 ITEM DESCR...
Page 13 - Beater Door Assembly
9 Model C300 Operator Parts Identification 140509 Beater Door Assembly Figure 3 ITEM DESCRIPTION PART NO. 1 DOOR A.- FREEZER- SLUSH X80599 2 CAP- SPOUT- DOOR- FCB 046191- BLA 3 SPRING- COMP.480X.072X3.0 039320 4 VALVE- DRAW- DOOR- SLUSH 039324 *5 O- RING- 9/16 OD X .103W 016369 6 SPOUT- DOOR- FCB- B...
Page 14 - Accessories
10 Model C300 Operator Parts Identification 140804 Accessories Figure 4 ITEM DESCRIPTION PART NO. 1 PAIL-10 QT 013163 2 BRUSH A.-PACKAGE X64275 2a BRUSH-MIX PUMP BODY-3”X7” 023316 2b BRUSH-DOUBLE ENDED 013072 2c BRUSH-REAR BRG 1”DX2“L 013071 ITEM DESCRIPTION PART NO. 2d BRUSH-DRAW VALVE 1-1/2”OD 014...
Page 15 - Important: To the Operator; Section 5; Control Switch; and water are satisfied.
11 Model C300 Important: To the Operator Section 5 Important: To the Operator Figure 5 ITEM DESCRIPTION 1 Product Light - Left Side 2 Control Switch 3 Keypad - Left Side 4 Liquid Crystal Display 5 Keypad - Right Side 6 Product Light - Right Side Control Switch The control switch is located at the to...
Page 16 - Operator Menu Display; OPERATOR MENU; Operator Menu Timeout; Screen B is FAULT DESCRIPTION; Fault Messages; NO FAULT FOUND
12 Model C300 Important: To the Operator Pressing the AUTO (- - >) keys on both sides of the unit will display this screen. AUTO MODE AUTO OK SYRUP OK CO2 - OK WATER - OK Line 1 indicates the operating mode for each freezing cylinder. Line 2 indicates the status of the syrup systems in each freez...
Page 22 - Assembly
18 Model C300 Operating Procedures 090417 Section 6 Operating Procedures The Model C300 contains two 7 quart (6.6 liter) freezing cylinders. CAUTION: This unit is pressurized when in operation. The control switch must be in the OFF position until the unit is completely assembled. No part should ever...
Page 23 - Operating Procedures
19 Model C300 Operating Procedures 090417 Step 2 Lubricate the inside diameter of the drive shaft seal. Install the drive shaft seal bushing in the drive shaft seal. Figure 7 Note: The drive shaft bushing must be positioned in the center of the drive shaft seal. Step 3 Slide the seal and bushing ove...
Page 27 - Sanitizing; Important: Make sure the sanitizer is completely
23 Model C300 Operating Procedures 080507 Sanitizing Note: If a unit is sanitized, and will not be used for an extended period of time, clean water should be used to flush all sanitizer from the lines. Remove the water from all the lines and components prior to storage of the unit. Upon return to se...
Page 31 - 20 Day Closing Procedure
27 Model C300 Operating Procedures Note: The position of the handle on the syrup sampling valve determines the direction of product flow. The down position opens the syrup sampling valve for collecting brix samples. The center position shuts off the product flow. The up position directs the flow of ...
Page 32 - Draining Product From the; Repeat Steps 1 and 2; Rinsing
28 Model C300 Operating Procedures Draining Product From the Freezing Cylinder Step 1 With a pail beneath the door spout, press the BEATER (- - - ) key. This will allow the beater to operate and CO 2 pressure will be maintained to push the product from the freezing cylinder. Open the draw valve and ...
Page 33 - Cleaning; Important: Make sure the cleaner is completely; Disassembly
29 Model C300 Operating Procedures 080507 Cleaning Step 1 Prepare an approved 100 PPM cleaning solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5 R or 2 gal. [7.6 liters] of Stera- Sheen R ) in a clean, empty pail. USE WARM WATER AND FOLLOW THE MANUFACTURER’S SPECIFICATIONS. Important: Make sure...
Page 34 - Brush Cleaning
30 Model C300 Operating Procedures 080926 Brush Cleaning Step 1 Prepare an approved 100 PPM cleaning solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5 R or 2 gal. [7.6 liters] of Stera- Sheen R ). USE WARM WATER AND FOLLOW THE MANUFACTURER’S SPECIFICATIONS. IMPORTANT: Follow the label direction...
Page 35 - Important: Operator Checklist; Section 7; WE RECOMMEND CLEANING AND SANITIZING; Troubleshooting Bacterial Count; monthly
31 Model C300 Important: Operator Checklist 080926 Section 7 Important: Operator Checklist During Cleaning and Sanitizing ALWAYS FOLLOW LOCAL HEALTH CODES Cleaning and sanitizing schedules are governed by your State or local regulatory agencies and must be followed accordingly. The following check p...
Page 36 - Winter Storage
32 Model C300 Important: Operator Checklist Winter Storage If the place of business is to be closed during the winter months, it is important to protect the freezer by following certain precautions, particularly if the building is subject to freezing conditions. Disconnect the freezer from the main ...
Page 37 - Troubleshooting Guide; Section 8; PROBLEM
33 Model C300 Troubleshooting Guide Section 8 Troubleshooting Guide PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 1. Product is too stiff. a. Too much water to syrup ratio. Improper brix adjustment. a. Adjust the brix accordingly. 25 b. Consistency control needs adjustment. b. Contact a service technician...
Page 39 - Parts Replacement Schedule; Section 9
35 Model C300 Parts Replacement Schedule Section 9 Parts Replacement Schedule PART DESCRIPTION EVERY 4 MONTHS EVERY 8 MONTHS ANNUALLY Scraper Blade X Drive Shaft Seal X Drive Shaft O- Ring X Freezer Door O- Ring X Draw Valve O- Ring X Door Spout O- Ring X Front Bearing X Prime Plug O- Ring X Black B...
Page 40 - Section 10 Limited Warranty on Equipment
36 Model C300 Limited Warranty on Equipment 131210 Section 10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor-branded freezer equipment ...
Page 42 - Limited Warranty on Parts
38 Model C300 Limited Warranty on Parts 131210 Section 11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor genuine replacement co...
Page 44 - must
40 Model C300 Limited Warranty on Parts LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNE...