Page 2 - 999 Carrier Commercial Refrigeration, Inc.; Taylor Company; a division of Carrier Commercial Refrigeration, Inc.
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: Amps Minimum Wire Ampacity: Amps Part ...
Page 3 - Table of Contents
Table of Contents Models 8752, 8756, & 8757 Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section 2 To the Operator 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sec...
Page 4 - Table of Contents - Page 2; civil and criminal penalties. All rights reserved.
Table of Contents Models 8752, 8756, & 8757 Table of Contents - Page 2 Rinsing 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - Installer Safety
1 Models 8752, 8756, 8757 To the Installer 131210 Section 1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. Installer Safety In all areas of the world, equip...
Page 6 - FOLLOW YOUR LOCAL ELECTRICAL CODES!
2 Models 8752, 8756, 8757 To the Installer 101122 Water Connections (Water Cooled Units Only) An adequate cold water supply must be provided with a hand shut- off valve. On the underside rear of the base pan, two 3/8” I.P.S. (for single- head units) or two 1/2” I.P.S. (for double- head units) water ...
Page 7 - To the Installer; Beater Rotation; Note: The following procedures should be; Refrigerant
3 Models 8752, 8756, 8757 To the Installer 130819 Supply cords used with this unit shall be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (Code designation 60245 IEC 57) installed with the proper cord anchorage ...
Page 8 - Compressor Warranty Disclaimer
4 Models 8752, 8756, 8757 To the Operator 131210 Section 2 To the Operator The freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The Taylor Models 8752, 8756, and 8757 are highly sophisticated pieces of equipment, and when properly operated a...
Page 11 - Operator Parts Identification; Section 4
7 Models 8752, 8756, 8757 Operator Parts Identification 130117 Section 4 Operator Parts Identification Model 8752
Page 12 - Item
8 Models 8752, 8756, 8757 Operator Parts Identification 111129 8752 Parts Identification Item Description Part No. 1 Panel A.- Front X22997 2 Stud- Nose Cone 022822 3 Bolt- Carriage 012347 4 Panel A.- Lower Side (R & L) X23956 5 Panel- Upper Side Left 028599 6 Hood 050464 7 Panel- Upper Rear 022...
Page 14 - 752 Beater Door Parts Identification
10 Models 8752, 8756, 8757 Operator Parts Identification 130116 8752 Beater Door Parts Identification Item Description Part No. 1 Seal- Drive Shaft 032560 2 Shaft- Beater 032564 3 Beater A.- 3.4 Qt. 1 Pin X46231 4 Clip- Scraper Blade 046236 5 Blade- Scraper- Plastic 046235 6 Kit A.- Beater- Front Sh...
Page 20 - Accessories
16 Models 8752, 8756, 8757 Operator Parts Identification 140814 Accessories Item Description Part No. 1 Brush- Mix Pump Body 023316 2 Brush- Pressure Switch 027647 3 Brush- Feed Tube 021101 4 Brush- Double Ended 013072 5 Brush- Rear Bearing 013071 6 Brush- Draw Valve 013073 7 Lubricant- Taylor 4 oz....
Page 21 - Important: To the Operator; Section 5
17 Models 8752, 8756, 8757 Important: To the Operator Section 5 Important: To the Operator Model 8752 Model 8756 Model 8757
Page 22 - Description; Symbol Definitions
18 Models 8752, 8756, 8757 Important: To the Operator Parts Identification for 8752, 8756, & 8757 Item Description 1 Power Switch (Toggle) 2 Reset Switch 3 Mix Refrigeration Control 4 STANDBY Key 5 WASH Key 6 AUTO Key 7 PUMP Key 8 Mix Low Indicator 9 Mix Out Indicator 10 Heater Switch Symbol Def...
Page 24 - Operating Procedures; Section 6; Assembly; MAKE SURE THE CONTROL SWITCH IS
20 Models 8752, 8756, 8757 Operating Procedures 071017 Section 6 Operating Procedures The Model 8752 has been selected to show you the pictured step- by- step operating procedures for both models contained in this manual. These models, for all practical purposes of operation, are the same. The size ...
Page 28 - Air/Mix Pump Assembly; DO NOT
24 Models 8752, 8756, 8757 Operating Procedures Step 7 Snap the design cap over the bottom of each door spout. Figure 14 Step 8 Install the rear drip pan. Slide the rear drip pan into the hole in the side panel. Figure 15 Step 9 Install the front drip tray and the splash shield beneath the door spou...
Page 32 - Air/Mix Pump Assembly Exploded View; Pump Assembly
28 Models 8752, 8756, 8757 Operating Procedures Air/Mix Pump Assembly Exploded View Item Description Part No. 1 Cap- Pump (Model 8752) 023324 Cap- Pump (Models 8756/8757) 021276- 9 2 Pin- Retaining 021276- 8 3 Pump Assembly X36201 3a Cylinder A.- Pump 022345- 1 3b Pin- Retaining 021276- 8 3c Piston ...
Page 33 - Sanitizing
29 Models 8752, 8756, 8757 Operating Procedures 080820 Sanitizing Step 1 Prepare a pail of approved 100 PPM sanitizing solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5 R or 2 gal. [7.6 liters] of Stera- Sheen R ). USE WARM WATER AND FOLLOW THE MANUFACTURER’S SPECIFIC- ATIONS. Place the pail of...
Page 35 - Priming; fresh
31 Models 8752, 8756, 8757 Operating Procedures 071017 Step 10 After 5 minutes, open the prime plug. Press the PUMP key. Pull the draw handle down and draw off the remaining sanitizer. Figure 41 Step 11 Once the sanitizer stops flowing from the door spout, close the draw valve. Press the PUMP and WA...
Page 36 - Closing Procedure
32 Models 8752, 8756, 8757 Operating Procedures 140306 Step 5 Place an empty pail beneath the door spout and open the draw valve. With the prime plug still in the UP position, press the PUMP key. This will allow the mix to be pumped through the freezing cylinder and force out any remaining sanitizer...
Page 37 - ALWAYS FOLLOW LOCAL HEALTH CODES.; Rinsing
33 Models 8752, 8756, 8757 Operating Procedures 140814 Step 3 Place the suction line in an empty pail in the mix cabinet. Step 4 If local health codes permit the use of rerun , place a sanitized, NSF approved stainless steel rerun container beneath the door spout. Open the draw valve and press the W...
Page 39 - Check Topping Pump Temperature
35 Models 8752, 8756, 8757 Operating Procedures Step 7 Using the long, flexible brush and the cleaning solution, clean the mix inlet tube(s) located in the mix cabinet. Thoroughly clean the tube(s) all the way up to the freezing cylinder. This area needs special attention because bacteria and milkst...
Page 40 - During Cleaning and Sanitizing; Troubleshooting Bacterial Count
36 Models 8752, 8756, 8757 Important: Operator Checklist 080820 Section 7 Important: Operator Checklist During Cleaning and Sanitizing ALWAYS FOLLOW LOCAL HEALTH CODES. Cleaning and sanitizing schedules are governed by federal, state, or local regulatory agencies, and must be followed accordingly. I...
Page 41 - Winter Storage
37 Models 8752, 8756, 8757 Important: Operator Checklist 080820 j 7. If your machine is air cooled, check the condensers for accumulation of dirt and lint. Dirty condensers will reduce the efficiency and capacity of the machine. Condensers should be cleaned monthly with a soft brush. Note: For machi...
Page 42 - Troubleshooting Guide; Section 8; PROBLEM
38 Models 8752, 8756, 8757 Troubleshooting Guide Section 8 Troubleshooting Guide PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 1. No product is being dispensed. a. Low on mix. The MIX OUT light is on. a. Add mix to the mix tank and press the AUTO key. 17 b. The power switch is in the OFF position. b. Plac...
Page 47 - Parts Replacement Schedule; Section 9
43 Models 8752, 8756, 8757 Parts Replacement Schedule Section 9 Parts Replacement Schedule PART DESCRIPTION EVERY 3 MONTHS EVERY 4 MONTHS EVERY 6 MONTHS ANNUALLY QTY. Scraper Blades X 2* Drive Shaft Seal X 1* Freezer Door Gasket X 1* Front Bearing X 1* Beater Shoes X 2* Draw Valve O- Ring X 2** Prim...
Page 48 - Section 10 Limited Warranty on Equipment
44 Models 8752, 8756, 8757 Limited Warranty on Equipment 131210 Section 10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor-branded freez...
Page 50 - Limited Warranty on Parts; No warranty
46 Models 8752, 8756, 8757 Limited Warranty on Parts 131210 Section 11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited warranty on new Taylor genuine r...
Page 52 - The owner; must
48 Models 8752, 8756, 8757 Limited Warranty on Parts LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ...
Page 53 - Parts List
Section 12 Parts List 49 + Available Separately Models 8752, 8756, & 8757 Parts List MAI N REF IG E RA T IO N SYST EM HP -62, 8752 - J6090915/ UP ,8756 - J5032993/ UP ,8757 - J51 11000/ UP DE S CRI P T IO N PART NUM BE R 8752 QTY . 8756 QTY . 8757 QTY . W ARR. CL AS S RE M ARKS PART S UP DA T E ...
Page 65 - 014 Carrier Commercial Refrigeration, Inc.
Model 8752 037808 04/14 Taylor Company 2014 Carrier Commercial Refrigeration, Inc. c GRN/YEL BLK BLK BLK/WHT GND L2 L1 OL COMP BTR PUMP FAN MIX A1 A2 BTR. CONTACTOR M A1 A2 COMP. CONTACTOR COMP L1 14 T3 T2 T1 L1 L2 L3 13 L1 L2 L3 13 14 T3 T2 T1 B B POWER SWITCH 2PDT POWER/RELAY BOARD GRN/YEL WHT BLK...