Page 2 - Table of contents
2 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Table of contents 20 Mar 2012 Table of contents 1 About this document ..............................................................................4 1.1 Revision history ..........................................
Page 4 - About; Validity
4 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies About this document 20 Mar 2012 1 About this document SX Configurator is supplied as an integral component of the SX Open software package, and is a necessary tool for the configuration of this software (refer ...
Page 5 - Revision history; Trademarks
5 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies About this document 20 Mar 2012 1.1 Revision history Version Date Changes Section New product name SX Open Correcting Typos, added clarifications Change default notification class to 31 3.7.6 New sections sched...
Page 6 - Quality assurance
6 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies About this document 20 Mar 2012 1.2.3 Quality assurance These documents were prepared with great care. • The contents of all documents are checked at regular intervals. • Any corrections necessary are included ...
Page 7 - Printing conventions; Printing conventions for the BACnet terms; Related documents; Title; BACnet objects
7 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies About this document 20 Mar 2012 1.3 Printing conventions 1.3.1 Printing conventions for the BACnet terms BACnet objects (standard and proprietary) are not written or marked out in any special way in the manual....
Page 8 - SX Open – Integration into BACnet; was developed specifically for this configuration; Import of OPC data descriptions; Integration into Desigo; SX Configurator
8 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX Open – Integration into BACnet 20 Mar 2012 2 SX Open – Integration into BACnet Figure 2-1 SX Open is a software package in the Desigo Open family, and is used to integrate third-party subsystems or devices w...
Page 9 - Note
9 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX Open – Integration into BACnet 20 Mar 2012 This file is part of the SX Open package, and is copied into the subfolder ...\ Config of SX Open datapath when SX Open is set up. As a rule, SX Configurator also r...
Page 10 - SX configuration workflow; Opening SX Configurator
10 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3 SX configuration workflow The workflow consists of the following main activities: • Opening SX Configurator (Section 3.1) • Checking global Excel settings (Section 3.2) ...
Page 11 - Preparation - Checking global Excel settings
11 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.2 Preparation - Checking global Excel settings To avoid problems when using SX Configurator with different language settings always use a dot as decimal separator and a ...
Page 12 - Importing data; import; Checking the OPC server
12 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.4 Importing data Section 4 contains all the background information associated with the import of OPC data. Action Step Menu/Button Procedure Select the relevant options ...
Page 13 - Editing the main configuration sheet; Completing the OPC section
13 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.7 Editing the main configuration sheet The worksheet and individual values are described in detail in section 5.2. Following the import of the OPC data, the OPC section ...
Page 14 - Completing the BACnet section
14 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.7.2 Completing the BACnet section Column Step Procedure BACnet Device Ref (required) 1 In the BACnet Device sheet, enter the reference to the BACnet device to which the ...
Page 15 - Completing BACnet information for binary objects
15 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.7.4 Completing BACnet information for binary objects Column Step Procedure Polarity (optional) 1 Enter 0 for normal polarity and 1 for inverse polarity, binary-input and...
Page 16 - Completing the BACnet trend info section
16 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 Column Step Procedure Enter as applicable: 0 = Alarm Notify Type (optional) 7 1 = Event Enter as applicable (addition of 3 event enable bits): 1 = to-offnormal enabled 2 =...
Page 17 - 0 Completing the function info section; Editing other sheets
17 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.7.10 Completing the function info section Column Step Procedure Avoid Default Mapping (optional) 1 Disable default mapping of alarms Blank or <>1 = Use item value ...
Page 18 - Compiling the SX configuration; Trend; sheet if necessary.; Adjust properties in; Schedule; sheet if necessary.; Create SX-OPEN files
18 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies SX configuration workflow 20 Mar 2012 3.10 Compiling the SX configuration The SX configuration is completed after creation of the downloadable SX Open configuration files (CSV files) and the BACnet object desc...
Page 19 - Importing OPC data; OPC data sources; OPCItemVariantType
19 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Importing OPC data 20 Mar 2012 4 Importing OPC data The data objects available on the OPC server (primarily the server object and the various OPC items with name, data type, type of access etc.) are defined by...
Page 21 - Full
21 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Importing OPC data 20 Mar 2012 4.2.1 Full All OPC items are displayed in full in the Configuration sheet, and the data can be edited as required. With a Full import, the default BACnet property is [PrVal] for ...
Page 22 - Based on device; red
22 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Importing OPC data 20 Mar 2012 4.2.2 Based on device This import type can be used when there are several devices of the same type to import, e.g. room controller devices in a 400-room hotel. Assuming that 400 ...
Page 23 - Import Location; Green
23 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Importing OPC data 20 Mar 2012 The Item Set sheet has a special use in cases where BACnet properties other than [PrVal] are to be mapped to or from an OPC item. The idea underlying these import types is to off...
Page 24 - Limitations
24 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Importing OPC data 20 Mar 2012 Figure 4-3 When Create SX-OPEN files is clicked, the colors green and blue revert to black . The red items always generate the following warning: **Warning** Row XX: Item does no...
Page 25 - Worksheets in SX Configurator
25 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5 Worksheets in SX Configurator SX Configurator is based on worksheets that contain data for the OPC/BACnet conversion. The data is arranged in separate sheets to prov...
Page 26 - Definition of used trendlog objects; Definition of used schedule objects; Color code
26 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Worksheet overview Contents Section Nofification-Class Definition of notification classes used in all configured BACnet devices. 5.2.6 Hash-Values Definition of hash-v...
Page 27 - Cover sheet; Cover; Administrative section; Apart from the; PROJECT NAME and AUTHOR
27 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.1 Cover sheet Figure 5-4 The Cover sheet contains basic project information, such as name, description and person(s) responsible, plus a section for general and opti...
Page 28 - PROJECT NAME
28 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 When the file is saved for the first time, the project name is automatically appended to the file name, making the file name unique. 1. Complete the PROJECT NAME field...
Page 29 - OPTIONS section
29 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.1.2 OPTIONS section Figure 5-8 This section (light yellow fields) allows you to modify the general behavior of SX Configurator and define the paths to any additional...
Page 31 - Default mapping; OPC
31 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.1.3 Default mapping An OPC item consists of: • Name • Value • Status • Time stamp Activating Default Mapping means that not only is the item value mapped to [PrVal] ...
Page 32 - default mapping
32 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 default mapping not generated default mapping generated Figure 5-9 This default mapping generates error events based on the sheet above, using the configured notificat...
Page 33 - Main Configuration sheet; Configuration; in the; Configuration; Mapping rules
33 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2 Main Configuration sheet Figure 5-10 The Configuration sheet contains the actual SX Open configuration with the rules for mapping OPC data to BACnet objects and pr...
Page 34 - OPC area
34 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 The sheet is divided into the following sections: • OPC • BACnet • general settings • analog objects settings • binary objects settings • multistate objects settings •...
Page 35 - Item Set Ref
35 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Column Description Item Set Ref Reference to an Item Set from the sheet of the same name. Can be used for this type of import. Device Set Ref Reference to a Device Set...
Page 36 - BACnet section
36 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.2 BACnet section Figure 5-14 The BACnet information has to be entered manually to define each mapped OPC item. In the simplest case, some (or all) OPC items are ma...
Page 38 - column in the; column is set to 1 for all objects. On; column is set to 1 in all rows; Force Update
38 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Figure 5-15 On start-up SX Open reads the current configuration and compares it with the configuration held in its internal data storage system. Property values of obj...
Page 39 - BACnet information for analog objects; Ref
39 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.3 BACnet information for analog objects Column Description BACnet Units For analog objects only: unit for the analog object. This can be the BACnet unit number (e....
Page 40 - BACnet information for binary objects; Active text assigns a value for present-value 1.; BACnet information for multistate objects; and the number of text entries in the appropriate
40 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.4 BACnet information for binary objects Column Description Polarity (optional) Polarity can be used to change an OPC item to positive logic, i.e. 0 as passive stat...
Page 41 - BACnet alarm info section; system function in a way similar to that used in; NC; to define a set of notification classes.; Notification classes
41 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.6 BACnet alarm info section Figure 5-16 SX Open supports the alarm system function in a way similar to that used in Desigo. The alarm function in each alarm-genera...
Page 42 - Keyname
42 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Column Description NC-Id NC-Id is the instance-number of the corresponding notification-class BACnet object. The predefined notification-classes are assigned instance ...
Page 44 - OPC Item; BACnet trend info section
44 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 For analog objects, the alarm function is activated via these columns. If the columns are left blank, no alarm is initiated. Alarm limits can be defined in the followi...
Page 46 - all
46 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Column Description Describes how to get the monitored value: 0 = use confirmed COV notification -1 = use unconfirmed COV notification Log interval >0 = poll monitor...
Page 47 - BACnet schedule object section
47 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.8 BACnet schedule object section As an option, SX can change a BACnet object value based on a schedule. For this purpose, a schedule object must be assigned to the...
Page 48 - Keyname of schedule object.
48 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Column Description Schedule Object Device ID The instance number of the device where the BACnet object to schedule is located. This entry may not be changed, too. Sche...
Page 49 - Section alarm suppression; Example
49 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.9 Section alarm suppression Figure 5-26 Column Description Propagation Delay A delay time before a BAD OPC quality will be delivered as a BACnet fault state. Defau...
Page 50 - objtype
50 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.2.10 Function info section Figure 5-27 Column Description Avoid Default Mapping Disables the default mapping for alarms individually. (Refer also to the information ...
Page 51 - sheet. If this field is; Important
51 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 To support VT_BSTR items e.g. for signaling a state, these strings must be translated in a unique number which can be handled by SX Open. These strings have to be mapp...
Page 52 - Item Set sheet
52 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.3 Item Set sheet Figure 5-29 • At least one entry must have [PrVal] as a property and must also define the BACnet object type. • Each entry is mapped with a BACnet p...
Page 53 - Value
53 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 Column Description Ref Unique set number used as a reference in the Configuration sheet. The Ref erence is a sequence number in two parts: main-item.sub-item ; all def...
Page 54 - sheet are created automatically after the item; Device Set sheet; sheet and the
54 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 To simplify the configuration process, it also possible to define just one Item Set with: Ref = OPC valid = OPC fields = 1 RSUA0 .Value 1 .1 RSUA0 .Status The basic li...
Page 55 - OPC Server sheet; Unique number of the OPC server, used as a reference in the
55 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.5 OPC Server sheet Figure 5-32 This sheet is used to store OPC server data, such as name, location and update rate. Normally, if the OPC item data is imported direct...
Page 56 - BACnet Device sheet; See Configuration Sheet
56 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.6 BACnet Device sheet Figure 5-33 All the information about the "virtual" BACnet devices is saved here. It is best to assign the BACnet objects according to ...
Page 57 - Units sheet
57 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.7 Units sheet Figure 5-34 This sheet lists all the units defined in the BACnet standard, together with their respective reference numbers. For each OPC server, you c...
Page 58 - State sheet; BACnet reference number for the state; Objects sheet; BACnet reference number for the object type; or; Standard Properties
58 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.8 State sheet Figure 5-35 This sheet can be used to associate text with the numerical states of multistate objects. Column Description Ref BACnet reference number fo...
Page 59 - Properties sheet; BACnet reference number for the property
59 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.10 Properties sheet Figure 5-37 This sheet lists the BACnet properties supported by SX Open for mapping the OPC data. To avoid having to enter the object type in ful...
Page 60 - Functions sheet; BACnet Client sheet
60 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.11 Functions sheet Figure 5-38 The Function sheet is for entry of the predefined functions available via the function block library, PRJLib.dll . Only the functions ...
Page 63 - BSTR Hash sheet; items and map a finite set of different texts to; BSTR Hash
63 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.13 BSTR Hash sheet Figure 5-41 SX Open can deal with VT_BSTR items and map a finite set of different texts to [PrVal] of e.g. a multistate input object. This mapping...
Page 64 - Upload of properties from a running system; An upload must be accomplished in following order:; Start; SX Upload; tool on target system.; SX Configurator reads the upload file and inserts the values in; Proceed with configuration.
64 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Worksheets in SX Configurator 20 Mar 2012 5.14 Upload of properties from a running system SX Configurator V2.1 supports the upload of properties from a running system, e.g. if a configuration shall be extended...
Page 65 - Messages
65 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Messages 20 Mar 2012 6 Messages A number of messages appear in the OPC import and SX export process. Some of these are self-explanatory, and others are described below. In the data export process, unused infor...
Page 66 - Examples; Mapping Limits from OPC; Item Name; Mapping VT_BSTR Items
66 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Examples 20 Mar 2012 7 Examples 7.1 Mapping Limits from OPC The following example shows how to map limits from OPC to an analog input object. Assume the following OPC items with associated meaning: Temperature...
Page 67 - Map VT_BSTR to BACnet Present_Value using defined strings and
67 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Examples 20 Mar 2012 Figure 7-1 The Hash-Value itself will be calculated by SX Configurator when compiling configuration and must not be calculated and entered manually. 2. Define for every text an associated ...
Page 68 - Defining a Calendar Object; Name of internal item
68 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Examples 20 Mar 2012 7.3 Defining a Calendar Object Calendar objects are created as container only. There will be no calendar entries inserted by SX-Configurator. Do add a calendar object to SX-Configurator a ...
Page 69 - SXVirtual; Adding a Schedule to an Object
69 / 72 Siemens Desigo SX Open - SX Configurator, V2.1 CM110702en_06 Building Technologies Examples 20 Mar 2012 As a last step entries in SXmapping.csv must be suppressed. This is done by using the special mapping function SXVirtual which is a trigger not to emit mapping entries for this row in Conf...
Page 71 - Index; Completing BACnet information
71 / 72 Siemens Desigo SX Open SX Configurator, V2.1 CM110702en_06 Building Technologies Index 20 Mar 2012 Index B BACnet client sheet .............................................. 60 BACnet printing conventions .................................. 7 BSTR Hash sheet .....................................
Page 72 - Main Configuration
72 / 72 Siemens Desigo SX Open SX Configurator, V2.1 CM110702en_06 Building Technologies Index 20 Mar 2012 U Units sheet ............................................................ 57 Upload of properties from a running system......... 64 Upload properties .............................................