Page 2 - Legal information
Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A2B00060666-05 Ⓟ 07/2014 Subject to change Copyright © Siemens AG 2008 - 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as wel...
Page 3 - Table of contents
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 3 Table of contents 1 Introduction ............................................................................................................................................. 5 1.1 On the Operating Instructions ...........................
Page 5 - Introduction; On the Operating Instructions; Purpose of the Operating Instructions; Validity of the Operating Instructions; Further documentation
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 5 Introduction 1 1.1 On the Operating Instructions Purpose of the Operating Instructions These Operating Instructions support you when commissioning networks with the Industrial Ethernet switches of the SCALANCE X-100 product line. Valid...
Page 6 - Audience; SIMATIC NET glossary; Security information
Introduction 1.1 On the Operating Instructions SCALANCE X-100 6 Operating Instructions, 07/2014, A2B00060666-05 Audience These Operating Instructions are intended for persons who commission networks with the IE switches of the SCALANCE X-100 product line. SIMATIC NET glossary Explanations of many of...
Page 7 - On the product
Introduction 1.2 On the product SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 7 1.2 On the product What is possible? The devices of the SCALANCE X100 product line allow the cost-effective installation of Industrial Ethernet bus and star structures with switching functionality. With ...
Page 8 - Components of the product; Accessories
Introduction 1.2 On the product SCALANCE X-100 8 Operating Instructions, 07/2014, A2B00060666-05 Components of the product The following components are supplied with a SCALANCE X-100: ● IE Switch SCALANCE X-100 ● 2-pin plug-in terminal block (signaling contact) ● 4-pin plug-in terminal block (power ...
Page 9 - Unpacking and checking
Introduction 1.2 On the product SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 9 Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use d...
Page 11 - Network topologies; Which topologies can be implemented?
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 11 Network topologies 2 Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion. Which topologies can be implemented? Using the IE switches of the SCALANCE X-100 product line, you ...
Page 13 - Description of the device; Overview of the SCALANCE X-100
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 13 Description of the device 3 3.1 Overview of the SCALANCE X-100 Table 3- 1 Overview of the product characteristics Device type SCALANCE X104-2 X106-1 X108 X108PoE X112-2 X116 X124 SIMATIC environment + + + + + + + Diagnostics LED + + +...
Page 14 - Product properties; Possible connections
Description of the device 3.2 Product properties SCALANCE X-100 14 Operating Instructions, 07/2014, A2B00060666-05 3.2 Product properties 3.2.1 SCALANCE X104-2 Possible connections The SCALANCE X104-2 has four RJ-45 jacks and two BFOC sockets for the connection of end devices or other network segmen...
Page 21 - RJ-45 connector pinout
Description of the device 3.3 TP ports (twisted pair) SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 21 3.3 TP ports (twisted pair) RJ-45 connector pinout With SCALANCE X-100, the twisted-pair port is designed as an RJ-45 jack with MDI-X pin assignment (Medium Dependent Interface Aut...
Page 22 - Autonegotiation; Auto polarity exchange
Description of the device 3.3 TP ports (twisted pair) SCALANCE X-100 22 Operating Instructions, 07/2014, A2B00060666-05 Note Permitted cable lengths TP cords or TP-XP cords with a maximum length of 10 m can be connected to the TP port with the RJ-45 jack. With the IE FC cables and IE FC RJ-45 plugs ...
Page 23 - Transmission speed; Transmission medium; Connectors
Description of the device 3.4 FO port (fiber optic) SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 23 3.4 FO port (fiber optic) Transmission speed The transmission speed of the optical Fast Ethernet ports is 100 Mbps. Transmission technique The transmission mode for 100Base-FX is spe...
Page 24 - LEDs
Description of the device 3.5 LEDs SCALANCE X-100 24 Operating Instructions, 07/2014, A2B00060666-05 3.5 LEDs Fault LED "F" (red LED) The fault LED indicates the incorrect functioning of the device. LED color LED status Meaning Red Lit The SCALANCE switch X-100 detects a fault. At the same t...
Page 25 - SET button; Function; Setting the fault mask
Description of the device 3.6 SET button SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 25 3.6 SET button Function With the SET button, you can display and change the set fault mask. Setting the fault mask Factory setting When supplied (factory defaults), the fault mask is set so tha...
Page 27 - Assembly; Types of installation
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 27 Assembly 4 4.1 Types of installation The devices can be installed in the following ways: ● Installation on a 35 mm DIN rail ● Installation on a SIMATIC S7-300 standard rail ● Wall mounting WARNING Ambient temperature between 55 °C and...
Page 28 - Installation on a DIN rail; Installation
Assembly 4.2 Installation on a DIN rail SCALANCE X-100 28 Operating Instructions, 07/2014, A2B00060666-05 4.2 Installation on a DIN rail Installation To install the device on a 35 mm DIN rail complying with DIN EN 50022, follow the steps below: 1. Place the second housing guide of the device on the ...
Page 29 - Uninstalling
Assembly 4.2 Installation on a DIN rail SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 29 Uninstalling To remove the device from the DIN rail, follow the steps below: 1. Disconnect all connected cables. 2. Release the DIN rail catch on the bottom of the device using a screwdriver. 3....
Page 30 - Installation on a standard rail
Assembly 4.3 Installation on a standard rail SCALANCE X-100 30 Operating Instructions, 07/2014, A2B00060666-05 4.3 Installation on a standard rail Installation on a SIMATIC S7-300 standard rail To install the device on an S7-300 standard rail, follow the steps below: 1. Place the first housing guide...
Page 31 - Wall mounting
Assembly 4.4 Wall mounting SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 31 4.4 Wall mounting To mount the device on a wall, you require the following: ● 4 wall plugs, 6 mm in diameter and 30 mm long ● 4 screws 3.5 mm in diameter and 40 mm long To mount the device on a wall, follow ...
Page 33 - Connecting up; Power supply; Pin number
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 33 Connecting up 5 5.1 Power supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When a redundant power sup...
Page 35 - Signaling contact
Connecting up 5.2 Signaling contact SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 35 5.2 Signaling contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (relay contact) is a floating switch with which error/fault states can be signaled b...
Page 36 - Grounding; S7 standard rail; Fitting the IE FC RJ45 Plug 180 to the IE FC Standard Cable
Connecting up 5.3 Grounding SCALANCE X-100 36 Operating Instructions, 07/2014, A2B00060666-05 5.3 Grounding Installation on a DIN rail The device is grounded over the DIN rail. S7 standard rail The device is grounded over its rear panel and the neck of the screw. Wall mounting The device is grounded...
Page 39 - Maintenance and troubleshooting; Possible sources of problems and how to deal with them; Fuses; Link display on the optical ports; LED display when voltage drops; Device defective
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 39 Maintenance and troubleshooting 6 6.1 Possible sources of problems and how to deal with them Fuses Some of the Industrial Ethernet switches of the SCALANCE X-100 product line have a resettable fuse / PTC. If the fuse triggers (all LED...
Page 41 - Technical specifications
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 41 Technical specifications 7 7.1 SCALANCE X104-2 Table 7- 1 Technical specifications of the SCALANCE X104-2 Technical specifications Order number SCALANCE X104-2 6GK5104-2BB00-2AA3 Connection to Industrial Ethernet Number 4 Design RJ-45...
Page 63 - Certifications and approvals; EMC directive; Installation Guidelines; Declaration of Conformity
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 63 Certifications and approvals 8 The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Issued approvals on the type plate of the device The specified approvals apply only when the corre...
Page 64 - Notes for the Manufacturers of Machines
Certifications and approvals SCALANCE X-100 64 Operating Instructions, 07/2014, A2B00060666-05 Notes for the Manufacturers of Machines The devices are not machines in the sense of the EC Machinery Directive. There is therefore no declaration of conformity relating to the EC Machinery Directive 2006/...
Page 65 - IECEx; cULus Approval for Information Technology Equipment
Certifications and approvals SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 65 IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following stand...
Page 67 - Dimension drawings
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 67 Dimension drawings 9 Figure 9-1 Dimension drawing, rear of the SCALANCE X104-2, X106-1, X108, X108PoE
Page 73 - Index
SCALANCE X-100 Operating Instructions, 07/2014, A2B00060666-05 73 Index A Accessories, 8 Approvals, 63 Auto polarity exchange, 22 Autonegotiation, 22 B Bending radii, 71 BFOC socket ST socket, 15 C CE mark, 63 Components of the product, 8 Connection to Industrial Ethernet, 41, 44, 47, 50, 53, 56, 59...