Page 2 - Disclaimer of Liability
© Siemens AG 2011 Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: Thi...
Page 3 - SITRANS RD10 0 Loop Powered Meter; Safety Notes
7ML19985JU01 SITRANS RD100 – INSTRUCTION MANUAL Page 1 SITRANS RD10 0 Loop Powered Meter SITRANS RD10 0 SITRANS RD100 is a 2-wire loop powered, NEMA 4X enclosed remote digital display for process instrumentation. This digital meter is easy to use with a display of 3.5 digits, 1" (2.54 cm) high. ...
Page 4 - Specifications
Page 2 SITRANS RD100 – INSTRUCTION MANUAL 7ML19985JU01 Specifications Display • 1.0 " (25.4 mm) high LCD, numeric display range from -1000 to 1999 Enclosure • Impact-resistant glass-filled polycarbonate body• Color: gray• Impact-resistant clear polycarbonate cover: NEMA 4X, Type 4X, IP67 Mountin...
Page 5 - Calibration; Approvals
7ML19985JU01 SITRANS RD100 – INSTRUCTION MANUAL Page 3 Calibration • Two-step; non-interacting low and high Calibration Range • 4 mA input: display of -1000 to +1000 counts• 20 mA input: display of 4 mA count value +20 to 2000 counts, to a max. display of 1999 counts Accuracy • ±0.1% of span ±1 coun...
Page 6 - Mounting; Wall Mounting; Dimensions
Page 4 SITRANS RD100 – INSTRUCTION MANUAL 7ML19985JU01 Mounting Wall Mounting Dimensions A: 80 mm (3.15") C: 60 mm (2.36") E: 65 mm (2.56") B: 140 mm (5.51") D: 120 mm (4.72") F: 20 mm (0.79") Wall mounting holes: Ø 4 mm (0.16") Weight: 340 g (12 oz) SIDE VIEW wall mounti...
Page 7 - Optional Panel Mounting Kit; Instructions; Notes
7ML19985JU01 SITRANS RD100 – INSTRUCTION MANUAL Page 5 Optional Panel Mounting Kit Instructions 1. Insert the RD100 through the mounting plate. 2. Mount the complete assembly on the panel. 3. Secure with 4 brackets and 4 screws (supplied) at the corners of the meter. Use washers as needed to allow f...
Page 8 - Connections; Calibrator connected to input signal PCB
Page 6 SITRANS RD100 – INSTRUCTION MANUAL 7ML19985JU01 Connections Calibrator connected to input signal PCB Control loop connected to input signal PCB display PCB component side(may be removed for bench calibration) LO calibration control HI calibration controlbalance control(factory adjust only) DP...
Page 9 - Calibrator connected to display PCB; • To maintain hazardous area protection, the input signal must
7ML19985JU01 SITRANS RD100 – INSTRUCTION MANUAL Page 7 Calibrator connected to display PCB WARNINGS: • To maintain hazardous area protection, the input signal must always be connected to the input signal PCB, and not directly to the display PCB. • Electrostatic hazard. Clean only with a moist cloth....
Page 10 - Setup; Calibration connections; Calibrator connected to input; Decimal point selection; Calibrator; Installation; Removing display PCB from the loop; • If any of the following operations are performed in the hazardous
Page 8 SITRANS RD100 – INSTRUCTION MANUAL 7ML19985JU01 Setup For calibration, a calibrated current source and a screwdriver are required. Calibration connections To access the input terminals, remove the enclosure cover and the display PCB. 1. Loosen the four screws on the enclosure cover and remove...
Page 12 - For more information
www.siemens.com/processautomation Printed in Canada www.siemens.com/weighing www.siemens.com/level For more information www.siemens.com/processautomation Siemens AG Industry Sector 1954 Technology Drive P.O. Box 4225 Peterborough, ON Canada K9J 7B1 Subject to change without prior notice 7ML19985JU01...