3U Traffic Outstation Handbook 667/HB/26568/000 Page 2 Issue 15 SAFETY WARNINGS In the interests of health and safety, when using or servicing this equipment, the following instructions must be noted and adhered to: (i) Only Skilled or Instructed personnel with relevant technical knowledge and exper...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 3 Issue 15 Maintenance Provision (MP) 1. Product Reference Siemens Remote Monitoring System Outstation Monitoring Control Unit (RMS OMCU) Siemens Car Park Count OMCU Siemens Bus Processor Siemens MOVA Unit 2. Specifications The Outstation Monitori...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 4 Issue 15 CONTENTS 1. INTRODUCTION .................................................................................................. 10 1.1 PURPOSE ....................................................................................................
3U Traffic Outstation Handbook 667/HB/26568/000 Page 9 Issue 15 TABLE OF FIGURES Figure 1 - Overview .................................................................................................. 12 Figure 2 - Basic OMCU to ST700 or ST800 ............................................................
3U Traffic Outstation Handbook 667/HB/26568/000 Page 10 Issue 15 1. INTRODUCTION 1.1 PURPOSE This document is intended to provide sufficient information to the user to install, configure and maintain the 3U Traffic Outstation, either as a Siemens RMS OMCU, a Bus Processor or a Siemens MOVA unit. 1.2...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 11 Issue 15 PSU - Power Supply Unit RAM - Random Access Memory RMS - Root Mean Square or Remote Monitoring System TCSU - Traffic Control and Systems Unit TRL - Transport Research Laboratory VC - Vehicle Classification
3U Traffic Outstation Handbook 667/HB/26568/000 Page 12 Issue 15 2. PRODUCT DESCRIPTION 2.1 INTRODUCTION Figure 1 shows an overview of a Siemens Traffic Outstation (shown with 2 LMU I/O boards and a single Bus / MOVA I/O board) and how it connects as a system. Figure 1 - Overview Processor Board Loc...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 14 Issue 15 Where a Modem is present, it can be connected through a land line to the PSTN or via a GSM 900 digital network. The unit can be communicated with and will report back faults via the PSTN or GSM. When a modem is not present, all Instati...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 20 Issue 15 2.6.2 The GSM TC35 Modem Unit (option) This replaces the M20 GSM Modem which is lo longer available. This modem is a dual band GSSM900/1800 unit but limitations of the aerial restrict it’s use in this application to the GSM900 network ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 21 Issue 15 2.7.1 The Power Supply Unit (PSU) Features (a) Wide range of AC input voltage (b) 3000V isolation from the mains (c) Can be fitted with a single 12V sealed lead acid battery (see section 7.6.3(a) on page 88) (d) Automatic switching to ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 24 Issue 15 3.5 ISOLATED OUTPUTS The I/O boards are each equipped with a number of relay isolated outputs, four normally open contacts on an LMU I/O board and 16 change-over contacts on a BUS / MOVA I/O board. The following describes the electrica...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 25 Issue 15 3.7 ISOLATED MAINS VOLTAGE INPUTS Each LMU I/O board also supports 10 fully software configurable photo-coupled mains voltage inputs and a fully configured OMCU provides 30 such inputs. The function of these inputs is to provide an iso...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 26 Issue 15 The four RS232 communications interfaces are shown on 667/GA/26580/000 sheet 2 in Appendix B and are as follows: 3.9.1 Communications Channel 1 (TR0141 Port) Location: On back edge of Processor Board (see 667/GA/26580/000 Sheet 2) in A...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 28 Issue 15 4. OMCU FACILITIES 4.1 INTRODUCTION The Siemens 3U Traffic Outstation provides a flexible multi-function hardware and software platform, with sufficient interfaces to allow sophisticated monitoring and control tasks to be developed and...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 31 Issue 15 4.2.5.1 Routing SIETAG Vehicle Detections to an OTU An overview of the SIETAG OMCU - OTU facility is shown in the following figure. TC12 OTU LOCAL HANDSET RS232 RS232 to OTU HANDSET PORT for UTC LOG TAG DETECTOR LOOP(S) RS485 VEHICLE T...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 33 Issue 15 etc. are also passed over the serial link allowing the OMCU and MOVA applications to read them as though they were connected directly to the unit. For more information on MOVA using the enhanced 141 link, see section 9.6.4 on page 117....
3U Traffic Outstation Handbook 667/HB/26568/000 Page 36 Issue 15 4.2.9.1 Force Bit Control Installation TRAFFIC CONTROLLER RS232 FORCE BITS LOCAL HANDSET DETECTOR LOOPS OMCU (with LGD Battery & MODEM) RMS PROTOCOL TO INSTATION SIGNAL HEADS GREEN CONFIRMS OPTION: GPS Receiver (clock) RS232/ RS485...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 37 Issue 15 4.2.9.2 ST800 Enhanced Serial Link Control Installation TRAFFIC CONTROLLER RS232 LOCAL HANDSET DETECTOR LOOPS OMCU (with LGD Battery & MODEM) RMS PROTOCOL TO INSTATION SIGNAL HEADS FORCE BITS, CONFIRMS, ETC OPTION: GPS Receiver (cl...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 38 Issue 15 4.2.9.3 Detector Control Installation TRAFFIC CONTROLLER RS232 DEMAND BITS LOCAL HANDSET DETECTOR LOOPS OMCU (with LGD Battery & MODEM) RMS PROTOCOL TO INSTATION SIGNAL HEADS GREEN CONFIRMS OPTION: GPS Receiver (clock) RS232/ RS485...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 39 Issue 15 For each interval completed a report is generated and stored in the Operations Log. When the final interval has been completed and report generation has been enabled, a report is written to the Fault Log to indicate that Flow Logging h...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 46 Issue 15 5. INSTALLATION WARNING THIS EQUIPMENT MAY ONLY BE INSTALLED BY SIEMENS TRAFFIC CONTROLS OR BY TRAINED PERSONNEL. AUTHORISED INSTALLER MUST ENSURE THAT INSTALLATION OF THIS EQUIPMENT DOES NOT INTERFERE OR DEGRADE THE DESIGN SPECIFICATI...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 47 Issue 15 5.1 INSTALLATION CHECK LIST The checklist on the following page should be used to install the unit together with the Instation computer printout for the equipment to be monitored. Installation techniques are shown on drawing 667/GA/265...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 48 Issue 15 INSTALLATION CHECKLIST STEP OMCU C/P BUS MOVA FUNCTION REFERENCE 1 OMCU C/P BUS MOVA Check unit supplied is as per installation computer print out WORK ORDER 2 OMCU C/P BUS MOVA Check unit contains correct I/O boards. Ensure LMU I/O bo...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 49 Issue 15 THE REST OF SECTION 5 TAKES YOU THROUGH THE STEPS IN THE INSTALLATION CHECKLIST (FROM THE PREVIOUS PAGE) IN MORE DETAIL… Section 5.2 takes you through the steps that ‘configure’ the hardware before the unit it is installed. Sections 5....
3U Traffic Outstation Handbook 667/HB/26568/000 Page 50 Issue 15 S5 S6 OR OR OR PSU CPU Card I/O Board #1 I/O Board #2 I/O Board #3 LMU I/O Board Bus MOVA I/O Board Edgeof theboard S1 1 4 ON 3 2 Edgeof theboard 1 5 6 ON 2 1 ON 2 ON 1 4 3 2 ON 1 4 3 2 ON 1 4 3 2 S1 ON 1 2 ON 1 2 ON 1 2 ON 1 2 ON 1 2 ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 51 Issue 15 For Example: To select 5V as the modem power supply: 1) Insert the black wire in to socket 34 for 0V. 2) Insert the orange link wire in to sockets 28 and 33 to select 5V. 3) Finally insert the yellow wire in to socket 27 (Modem +ve sup...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 53 Issue 15 Note 2: Pins 11, 13 and 14 should be connected as shown on the first LMU I/O board only. These pins should be left unconnected on the second and third boards fitted to a unit. If 120V operation is required then a different variant of t...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 54 Issue 15 5.2.6 Output Resistor Options (BUS / MOVA I/O Board Only) 9 — — BUS MOVA Set up Bus/MOVA output relay resistors 5.2.6 The BUS / MOVA I/O board has two switches to select the resistor values on the last two outputs: The first switch sel...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 55 Issue 15 5.4 HARDWARE INSTALLATION 5.4.1 General Installation The unit assembly is a 3U extended unit, requiring 192mm of 3U Rack space. This feature, together with the configurable cableforms, provides sufficient flexibility to install the har...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 56 Issue 15 5.4.2 Radio Clock Installation [This section only applies to Bus applications] The optional Radio Clock is a separate unit that is mounted external to the OMCU using a bracket supplied with the unit. It provides a time signal to the tr...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 59 Issue 15 Figure 13 - Current Sensor Connection Berg Mini-Latch Housing Polarisation Pip Voltage Monitoring Transformer Input on I/O Board 1 First Current Input on I/O Board 1 (Second Current Input on Boards 2 & 3) To Lamp Supply From Contro...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 61 Issue 15 5.6.2 Lamp Supply Sensor Connection 14 OMCU — — — Connect lamp supply sensor (Unless using ST800 enhanced serial link) 5.6.2 The lamp supply sensor (Voltage Monitoring Transformer) should be connected to the cabinet lamp supply as foll...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 62 Issue 15 Note: This connector is also used by the OMCU to monitor the state of other mains level signals, such as the controller’s mains supply (after its switches and fuses) for example, which is normally connected to the first mains state inp...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 65 Issue 15 Any of these ports, up to a total of four, may be used for N+1 flow counting. If this is the case the uses of the first five inputs on the port have the following fixed allocation: Input 0 - "A" detector (by convention furthest...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 66 Issue 15 I/O Board Connector PL1 and PL2 Connector Allocation Pin Board 1 PL1 Board 1 PL2 Pin Board 2 PL1 Board 2 PL2 1 Buffered I/P 1 Buffered I/P 25 1 Buffered I/P 49 Buffered I/P 73 2 Buffered I/P 2 Buffered I/P 26 2 Buffered I/P 50 Buffered...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 69 Issue 15 5.6.6 BUS / MOVA Board RS485 Serial Ports 18 — — BUS — Connect RS485 cables, e.g. for SIETAG 5.6.6 The following Table shows the RS485 connector pin assignments on each BUS/MOVA I/O board. 1 2 End Connector Socket Positions Not Used Po...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 70 Issue 15 NB: Ensure that the Sietag backplane is fitted with a link connecting the through-hole immediately above silk screen number "14" to the through-hole above silk screen number "21". The line termination resistors on the B...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 71 Issue 15 (c) Check On Integrity of Neutral Connections With the controller switched on and cycling and a multi-meter set to measure AC volts - measure the voltage between each green feed and neutral, when the green is off. The voltage should be...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 72 Issue 15 Insert this cable into plug PL4 (SIL 18 way) on the processor board (see drawing 667/GA/26580/000 in Appendix B ), and the other end (25 way 'D' Type), into the appropriate 'Handset Socket' of the OTU. Note: This cable is required if t...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 73 Issue 15 When installing the Siemens OMU the detector monitoring inputs require access to the same 24VDC supply as is used to reference the detector inputs. At present this is not directly available. To make the 24VDC supply available to the Si...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 74 Issue 15 6. OMCU COMMISSIONING WARNING THIS EQUIPMENT MAY ONLY BE COMMISSIONED BY SIEMENS TRAFFIC CONTROLS OR BY TRAINED PERSONNEL. ENSURE THAT THE UNIT IS NOT CONNECTED TO THE PSTN LINE JACK UNIT AT THE COMMENCEMENT OF COMMISSIONING TESTS. ZX0...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 76 Issue 15 OMCU Car Park BUS CHECK REFERENCE 3 9 Controller Checks The controller to be monitored should be checked to verify that: a) All lamps are working, including WAIT lamps; b) All the detection is working; c) All push buttons are working; ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 79 Issue 15 OMCU Car Park BUS CHECK REFERENCE 20 9 9 Dial Out & Dial In Checks Connect OMCU Telephone Connector and a Telephone Handset (e.g. BT ref. 248/2) into a Dual Outlet Adapter (BT ref. LJU10/3A). Connect the Dual Output Adapter into th...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 81 Issue 15 OMCU Car Park BUS CHECK REFERENCE 30 9 PAKNET check (if Fitted) With car park count systems the PAKNET interface is used to transmit data to the Instation. The following parameters must be set-up via the handset. a) Enable the PAKNET i...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 89 Issue 15 8. FAULT FINDING AND REPAIR 8.1 INTRODUCTION The following section comprises of battery, telephone connection information and warnings, together with quick reference tables, to provide a guide to aid fault tracing on the unit for first...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 101 Issue 15 9. MOVA 9.1 MOVA Introduction IMPORTANT: BEFORE LOADING ANY CONFIGURATION DATA, REFER TO SECTION 9.6.7 ON PAGE 120. The following is an extract from the introduction of AG10. MOVA stands for Microprocessor Optimised Vehicle Actuation,...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 102 Issue 15 MODEM PSU SIEMENS OMCU and MOVA UNIT Non -MOV A I n pu ts Ph as e G re e ns & L M U MO V A D e te c to rs MO V A C o n firm s MO V A F o rc e B its Telephone Line To Handset or PC On-Site P rocesso r Bo ar d L M U I/O Bo ar d (s )...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 104 Issue 15 Also note that PB681 issue 10 can use the enhanced 141 serial link to an ST800 through which it obtains all of its detectors and confirms from, and passes its force bits to, the controller. See section 4.2.6 on page 32 and section 9.6...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 106 Issue 15 MOVA Digital I/O Connections Pin Wire Colour Board 1 PL1 Board 1 PL2 Board 2 PL1 Board 2 PL2 1 Blue Detector 1 Detector 25 Detector 33 Detector 57 2 Yellow Detector 2 Detector 26 Detector 34 Detector 58 3 Brown Detector 3 Detector 27 ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 108 Issue 15 9.4 Telephone Line Sharing Connections When a separate Siemens OMCU unit and Siemens MOVA unit share the same telephone line, the two units ‘communicate’ with each other using two I/O lines. For details of how to communicate remotely ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 109 Issue 15 If problems are experienced with the telephone line sharing system, the following should help diagnose the cause of the problem: • Check that the OMCU has been installed, commissioned and configured correctly. The telephone line shari...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 113 Issue 15 9.6 MOVA Commissioning Detail This section expands on the steps in the commissioning checklist from the previous section… Note that where a separate OMCU unit and MOVA unit are both being installed together into a controller and the t...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 114 Issue 15 9.6.1 Communicating Locally with the MOVA Unit 7) 9.6.1 Connect the PC to the MOVA unit’s local port (the 25 way D-type connector on the front of the processor board) and start the MOVA communications application. Connect a normal con...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 115 Issue 15 9.6.2 Complete Initialisation 8) 9.6.2 Initialise MOVA by entering the handset command INI=2. If the OMCU application is not required, enter INI=3 to completely re-initialise the whole unit. [Prior to issue 10 – set the ‘Phone Home’ f...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 116 Issue 15 9.6.3 Phone Line Sharing Facility (PLS) 9) 9.6.3 Ensure the unit has correctly determined whether the Phone Line Sharing facility to a separate OMCU is required (‘ PLS:1 ’ if enabled and ‘ PLS:0 ’ if disabled). If not, investigate the...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 127 Issue 15 number of stages plus one (e.g. 6 on a 5-stage junction) then the warm-up cycle is said to be complete. This warm-up cycle allows the MOVA unit to gather information about the junction before it takes control. Following various fault ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 128 Issue 15 9.7 MOVA Communications Notes Assistance on communicating locally with the MOVA unit during commissioning is provided in the previous section within the appropriate steps in the commissioning checklist, e.g. section 9.6.1 on page 114....
3U Traffic Outstation Handbook 667/HB/26568/000 Page 129 Issue 15 ATZ .........................................to reset the modem Ok ...........................................accepted by the modem AT+MS=2,0 ............................to select V22bis protocol Ok ......................................
3U Traffic Outstation Handbook 667/HB/26568/000 Page 135 Issue 15 10. CAR PARK COUNT and PAKNET 10.1 Overview The car park monitor facility is primarily designed for use with the PAKNET communication interface and a SIESpace Instation. The current occupancy of a car park is returned to the SIESpace ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 136 Issue 15 • To modify specific Car Park facility configuration data when requested by a Central Office • To provide handset commands to modify the Car Park facility configuration data 10.2 OMCU Status Message to SIESpace The OMCU generates the ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 137 Issue 15 - Initially, every 10 seconds for 10 attempts - Then, every hour for 5 attempts - Then, every 24 hours until comms is re-established Prior to PB680 issue 13 firmware, comms is only retried every 10 seconds for 10 attempts. 10.3 Differ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 138 Issue 15 Extrapolation A straight line extrapolation is made N minutes into the future to assess whether the car park is filling or emptying at a fast enough rate to require more frequent status reports to the Central Office. The extrapolation...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 142 Issue 15 11. HANDSET FACILITIES 11.1 INTRODUCTION Access to the status information is gained by entering codes on an approved handset and interpreting the response on the display. The handset port connector is a 25-way female D-type and operat...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 150 Issue 15 11.1.4 Write Procedure (Change Existing Data) 1. Plug the handset into the socket on front of the OMCU. 2. When the OMCU displays the prompt character ‘ - ’, carry out the appropriate level access enabling operation (described in info...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 152 Issue 15 11.2 HANDSET COMMAND ERROR CODES Code Name Description/Mnemonic A Access Level Access level for this command has not been enabled. Use PME. C Non-configured THE FACILITY TO WHICH THE COMMAND RELATES IS NOT AVAILABLE D Data Integrity T...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 157 Issue 15 MSI - 0 - 2 - Display Mains state inputs. Minor index: MSI 0 - first 8 mains I/Ps on first I/O Board. MSI 1 - last 2 mains I/Ps on first I/O Board & first 6 mains I/Ps on 2 nd I/O Board MSI 2 - last 4 mains I/Ps on 2 nd I/O Board ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 160 Issue 15 11.6 FAULT DATA COMMAND TABLE CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL FDC 0 – 8 0 - 1 - Display Fault Diagnostics See 11.6.1 RW FFC EXL 0 – 15 (**2) - Display LONG EXTENSION fault Filter count for ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 162 Issue 15 11.6.2 General Fault Data Display Format The FLT command displays a list of current faults (use + and - to scroll through the list). The format is as follows: ‘!’ = Urgent fault ‘ ’ = Non-urgent fault Fault code Fault data FLT:!VLF A ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 163 Issue 15 * = Code only used in the fault log (FLG), not the current fault list (FLT) † = More details on these codes is provided in the subsections after this table Code Description <Additional Parameters> - Notes ABF Amber Ball lamp Fau...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 179 Issue 15 11.8 MAINTENANCE COMMAND TABLE CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL BAS - - 0 - 2 Handset Display Base: 0 = Binary, 1 = HEX, 2 = Decimal open CAL - - 0 - 1 Call Instation: Request local dial-bac...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 182 Issue 15 CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL SOP (PB680 issue 5 or later) 0 - 2 board number - BINARY Set output ports - sets/displays the state of the 16 outputs on Bus / MOVA I/O board ‘n’ (0-2), e.g....
3U Traffic Outstation Handbook 667/HB/26568/000 Page 189 Issue 15 3. Corrupt Detect message entry 25-APR-99 10:51:10 E:D4 M:.034578768. E: = Error code (HEX) : D2 = Invalid LAN Address D4 = Invalid Message Type D6 = Invalid Checksum D8 = Bad Format Message M: = Message characters as received on the ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 190 Issue 15 11.10 BUS CONFIGURATION COMMAND TABLE Code Major Index Minor Index Data Range Description Access Level JID - - 0 - 9 and <space> Junction ID: The ID can only be set if the OMCU is unconfigured (forced by INI=1). 16 digits maximu...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 191 Issue 15 Code Major Index Minor Index Data Range Description Access Level BFR - - 0 - 2 Bus DFM Fault Reporting: 0 = no fault reporting 1 = non-urgent (interrogation only) 2 = urgent report (dial out) Maint 0 0 - FF Output Association List Bea...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 192 Issue 15 Code Major Index Minor Index Data Range Description Access Level 0 0 - n Output Action List Output Period: 0-n = Time for which the Detect Outputs are activated, in 0.1 sec units (100 sec max. for SIETAG, 2 sec max for TCSU) 1 0 - n S...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 198 Issue 15 Code Major Index Minor Index Data Range Description Access Level 0 0 - 63 Ramp Up Time Threshold The number of minutes before the FULL state is reached at which ramp up mode is entered 1 0 - 15 Ramp Up Period The interval in minutes b...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 199 Issue 15 11.13 PAKNET COMMAND TABLE Code Major Index Minor Index Data Range Description Access Level RCA - - 14 ASCII digits 0 - 9 Remote Comm’s user address (NUA) of the form : 2353ABCDEFGHIJ 2353 is the Data Network Identification Code alloc...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 201 Issue 15 CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL CYC - CLF plan 0 - 15 0 - 255 secs CYC le time for the specified CLF plan. 0 to 254 = cycle time 255 = plan is disabled RO MTS - 0 - 31 Stream No - M oni T o...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 203 Issue 15 11.14.2 Accessing CLF Configuration Data Commands CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL ACF - - 0 - 1 CLF A ction on C ompliance F ail. This is the action that is performed when the OMCU detects ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 204 Issue 15 CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL IFN Influe set 0 – 15 CLF group 0 - 31 Influe Type 0 - 3 I nfluence F u N ction i.e. which function does this group perform in the specified influence set. R...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 206 Issue 15 CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL TSH Entry 0 - 31 Second Index 0 - 1 0 = start 1 = end Date DDMMMYY The T imetable S pecial H oliday table defines up to 32 periods between the specified star...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 207 Issue 15 11.14.2.1 Influence Function (IFN) Each influence function is described below: Type Explanation 0 Deactivate - Deactivate all outputs associated with this output action stream 1 Activate - Deactivate any existing outputs for the strea...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 208 Issue 15 TSW N 4 : 3 TSW N 5 : <TimeSwitch Event Number 0 to 31> The operation code ‘3’ tells the OMCU to introduce the timeswitch event specified by ‘TSW N 5’, without affecting any other timeswitches. TSW N 4 : 4 TSW N 5 : <TimeSwit...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 209 Issue 15 CODE MAJOR INDEX MINOR INDEX DATA RANGE DESCRIPTION AND REMARKS ACCESS LEVEL CKM - - text GPS C loc k m onitor command is used to display the last message from the GPS receiver. This will indicate if the OMCU is getting valid GPS cloc...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 216 Issue 15 4 0 – 11 or 250 Transmission Communications Link Indicates on which communications link the messages identified by Transmission Message ID are to be transmitted. 0 – 11 = RS485 serial port 250 = MCE141 port 255 = no port selected 11.1...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 217 Issue 15 4 0 – FF Logging Control Byte 1 Controls whether VC events are to be logged for a given lane at the site. Bit 0 = Logging enable for lane 0 : Bit 7 = Logging enable for lane 7 Bits 0 to 7 set to a 1 indicates logging enabled for the c...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 220 Issue 15 11.18.1.9 Vehicle Classifier Speed Display Code Major Index Minor Index Data Range Description Access Level SDF - - 0 – 1 Speed Display Format Determines in which format the vehicle speed is displayed by the OLG handset command when a...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 222 Issue 15 11.18.1.13 Vehicle Classifier Detect Condition Statistic Category Map Code Major Index Minor Index Data Range Description Access Level VSM - 0 – 31 0 – 15 Statistic Category Identifies the statistic category that is to be incremented ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 227 Issue 15 Appendix A MOVA INSTALLATION SHEETS The following two A5 pages may be photocopied onto a single A4 sheet. A copy of this sheet should be completed for each MOVA installation and kept in the controller cabinet as a record of the MOVA i...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 228 Issue 15 MOVA INSTALLATION SHEET (1/2) Site Name and Location: MOVA Licence Number: Installation By: Date: MOVA Detector Inputs Det. No. Use / Name Controller / Det. Terminal Det. No. Use / Name Controller / Det. Terminal 1 17 2 18 3 19 4 20 5...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 229 Issue 15 MOVA INSTALLATION SHEET (2/2) MOVA Force and Confirm Bits Det. No. Use / Name Cont. Terminal Det. No. Use / Name Cont. Terminal Det. No. Use / Name Cont. Terminal TO CRB G9 F1 G1 G10 F2 G2 G11 to G16 require a 2nd Bus/MOVA I/O Card F3...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 230 Issue 15 Appendix B OMCU DRAWINGS B.1 Introduction Section B.2 contains a list of the drawings that are included at the back of this handbook. B.2 Drawing List (a) 667/GA/26580/000 Traffic Outstation Unit Assembly (b) 667/GA/26577/000 Traffic ...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 231 Issue 15 INDEX — A — ACF (CLF Action on Compliance Fail) ................................................................... 203 ACT (Bus Output Action List) ......................................................................... 192, 195 AD...
3U Traffic Outstation Handbook 667/HB/26568/000 Page 241 Issue 15 LAST PAGE OF THE 3U TRAFFIC OUTSTATION HANDBOOK
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual