MICROMASTERMICROMASTER VectorMIDIMASTER Vector Variable-SpeedDrives up to 90kW Catalog DA 64 - 2002/03 1. Introduction Product overviewTechnical dataConformance to International StandardsQuotation text 2. Technical Description Power sectionClosed-loop controlBrakes 3. Engineering information Technic...
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 1/0 1. Introduction 1/1 1.1 Product overview 1/1 1.2 Technical data 1/2 1.3 Conformance to International Standards 1/3 1.4 Quotation text 1/5
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 1/2 1. INTRODUCTION The MICROMASTER, MICROMASTER Vector andMIDIMASTER Vector drive inverters use state-of-the-artIGBT power semiconductors and represent the result ofyears of experience in the area of d...
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 1/3 Version D 1.2 Technical data Drive inverter MICROMASTER MICROMASTER Vector MIDIMASTER Vector Line supply voltage 1-ph. 208 V – 240 V AC ±10%3-ph. 208 V – 240 V AC ±10% 3-ph. 380 V - 500 V AC ±10% 3-ph. 208 V ...
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 1/4 1.3 Conformity to International Standards 1.3.1 CE Mark: The MICROMASTER, MICROMASTER Vector and MIDIMASTER Vector drive inverters fulfill the requirements of the Low-VoltageDirective 73/23/EC and t...
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 1/5 Version D 1.3.3 Limit values for harmonic currents in non-industrial² applications EN 61000-3-2 Since the 1 st of January 2001, all electrical equipment, which fall under the EMC Directive must fulfill the re...
INTRODUCTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 1/6 1.4 Quotation text 6SE92 MICROM ASTER IP20/NEM A1 0.12 to 3 kW , 1-ph. 208 - 240 V AC +/- 10%0.12 to 4 kW , 3-ph. 208 - 240 V AC +/- 10%0.37 to 7.5 kW , 3-ph. 380 to 500 V AC +/- 10% 6SE32 MICROM AS...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 2/0 2. Technical Description 2/1 2.1 Power section 2/1 2.2 PID closed-loop control 2/6 2.3 Shutdown (stopping) a motor 2/6 2.4 EMERGENCY OFF / safe standstill 2/7 2.5 Diagram of COMPOUND BRAKIN...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 2/2 2. TECHNICAL DESCRIPTION MICROMASTER, MICROMASTER Vector and MIDIMASTER Vectorare a series of drive inverters which are designed to be directlyconnected to the line supply. They are self-co...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 2/3 Version D 2.1.5 Vector control principles What is vector control? This is most easily explained by comparing with a DC motor. In a DC motor, the magnetic field is separately wound, so that the armatu...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 2/4 5 Frequency (Hz) 2.5 Constant current + orientation range Fully-orientated Vector control Constant current range 200 The above diagram illustrates the operating ranges of theMICRO/MIDIMASTE...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 2/6 2.1.12 MICRO/MIDIMASTER Vector (sensorless vector control) This control type is preferably used for single drives with asynchronous motors where the requirements placed on the dynamicrespon...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 2/7 Version D 2.1.13.1 Features of different control techniques Mode V/Hz FCC SVC Digital setpoint resolution 0.01 Analog setpoint resolution 10 bit Internal frequency resolution 0.01 Speed accuracy - co...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 2/8 2.3 Shutting down (stopping) a motor A drive can be shutdown in several ways: · Selecting OFF 1 (P051 to P055 or P356 = 1 or 2), this means that whenthe ON command is reset, the drive inver...
TECHNICAL DESCRIPTION MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 2/9 Version D 2.5 Diagrams of COMPOUND BRAKING TM , DC current and regenerative braking Regenerative braking · Energy is dissipated in an external resistor · Excellent braking torque · Smooth · Controlle...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/0 3. Engineering information and instructions 3.1 Technical comparison table 3/1 3.2 Dimensions and weights 3/2 3.3 Degrees of protection 3/5 3.4 Design guidelines 3/6 3.5 ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/2 3.1 Technical comparison table MICROMASTER 6SE92 MICROMASTER Vector 6SE32 MIDIMASTER Vector 6SE32 Power range 120 W - 3 kW, 230 V, 1 AC120 W - 4 kW, 230 V, 3 AC370 W – 7....
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/3 Version D 3.2 Dimensions and weights B H T H1 A DIN rail Depth D B H H1 F Size A 2 bolts M4 2 nuts M4 2 washers M4 Æ Æ = 4.5 mm MICROMASTER und MICROMASTERVector inverters must be ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/4 B H T Depth D H1 H Æ Æ = 8,5 mm Housing sizes 4, 5 and 6 4 bolts M8 4 nuts M8 4 washers M8 B1 B MIDIMASTER Vector – sizes 4, 5 and 6Standard version: IP21 Version with in...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/5 Version D MIDIMASTER Vector Size Type 3-ph. 208 – 240 VAC 3-ph. 400 – 500 VAC 3-ph. 525 – 575 VAC MDV220/4MDV400/4MDV550/2MDV550/4MDV750/2MDV750/3MDV750/4 MDV1100/2MDV1100/3MDV1100...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/6 3.3 Degrees of protection The IP number defines thedegree of protection against theingress of dirt, foreign bodies,water etc. (Ingress Protection;IP) for the associated d...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/7 Version D Separate filter Metal mounting plate Supply Retain the motor and control cables to the metal plate using suitable clamps . 3.4 Mounting and installation guidelines Fig. 3...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/8 3.5 Line supply The drive inverters are designed for limit values defined in the following standards. These standards describe the noise voltagespermissible at the line s...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/9 Version D 3.6 Control connections MICROMASTER: P Jog M PE U, V, W 3 ~ CPU AD SI 2 3 4 5 6 1011 PE 1/3-ph. 230 V AC 3-ph. 380 - 500 V AC L/L1, N/L2orL/L1, N/L2, L3 1 7 +10 V 0 V – +...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/10 MICROMASTER Vector & MIDIMASTER Vector 8 17 CPU AD RS485 3-ph. 208 - 230 V AC3-ph. 380 - 500 V AC3-ph. 525 - 575 V AC 2 3 L1, L2, L3 4 DC- 15 27 26* 25 24 23* 22 21 ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/11 Version D MICROMASTER Vector & MIDIMASTER Vector Output relay max. 2,0 A/110 V AC 0.8 A/ 240 V AC ( overvoltage Cat. 2 ) or 2 A/ 30 V DC (ohmic load) Control terminals 12 13 1...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/12 3.7 Recommended cable cross-sections MICROMASTER Vector MICROMASTER Basic Recommend-ed cablecross-section,line side Recommend-ed cablecross-section,motor side Max. cable...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/13 Version D MIDIMASTER Vector Torque application Recommend-ed cablecross-section,line side Recommend-ed cablecross-section,motor side Max. cablecross section MDV550/2 Constant torqu...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/15 Version D 3.8 Max. motor cable lengths Drive inverterpower Rated voltage Housingsize Without output reactor With output reactor KW V Non-shieldedcable M Shieldedcable m Non-shield...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/16 3.9 De-rating Voltage and current de-rating for high installation altitudes 100 90 80 70 60 100 90 80 70 60 500 1000 2000 3000 4000 1000 2000 4000 100 Installation altit...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/17 Version D Maximum output current referred to the pulse frequency As a result of higher switching losses at increased switching frequencies, the maximum continuous current (100 %) ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/18 3.10 Selection aid for motors A detailed description of the motors and selection tables isprovided in the following Catalogs: M 11: Three-phase low-voltage squirrel-cage...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/19 Version D Motor protection: MICROMASTER Vector and MIDIMASTER Vector: The motors are protected using a PTC thermistor. This isconnected to the drive inverter control terminals. Th...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/20 When selecting the output reactors, the max. outputfrequency and the max. pulse frequency should be taken intoaccount.It is not possible to use sinusoidal or dv/dt filte...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/21 Version D 3.11 Maintaining the EMC Directives Since January 1996, all manufacturers/companies assembling electrical equipment which have an autonomous function and whichare offere...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/22 Class 2: Filtered industrial environments For this level, manufacturers/companies assembling electrical equipment can themselves certify that their equipment is inconfor...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/23 Version D 3.12 Technical data for line and output filter 6SE3290-0BA87-0FB0 Radio interference suppression filter, Class B; 1-ph.; 208V – 240 V AC+/-10%; 3A; 50/60Hz 6SE3290-0BA87...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/29 Version D 6SE3290-0DG87-0FA5 Radio interference suppression filter, Class A; 3-ph.; 208V – 460V AC+/-10%; 34A; 50/60Hz Fi nely- str anded wire Fi nely- strand ed wi re
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/33 Version D 6SE2100-1FC20 EMC input filter, Class B Radio interference suppression filter, Class B; 3-ph.; 208V – 460V AC+/-10%; 38A; 50/60Hz DA64-5005 115 1 40 m ax . 15 6 L1 L2 L3...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/34 dV/dt output filter (MASTER DRIVES series) dV/dt output filter, Sizes B and C D H W ) d c b f 1 a ) 1 dV/dt output filter Size B C E H [mm] 425 600 1050 W [mm] 135 180 2...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/35 Version D 3.13 Line supply harmonics and line supply impedance Line supply harmonics In operation, the drive inverter causes non-sinusoidal line currents with harmonics. These har...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/36 Calculating a line reactor using an example.u K = short-circuit rating of the transformer as a % S n = rated apparent transformer rating S K = system fault level u i = r...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/37 Version D 3.14 Technical data & dimensions for line reactors & output reactors Line reactors, MICROMASTER Order No. [MRPD] Enclos- ure size Curr- ent Voltage Weight 6SE640...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/40 Technical data for line reactors 4E... Please refer to Catalog PD30 2001 for more details 3-phase line supply reactors 4EM... dimensions with terminals for any reactor a...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/43 Version D 3-phase line supply reactors 4EP... dimensions with flat connector for any reactor arrangement I Ln = 51 A n n n n e l l 2 2 1 1 4 3 b 1 d d 1 2 h nn n n 42 1 3 d 3 n 3 ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/44 Three-phase line reactors 4EU... dimensions with flat connectors, for mounting reactors onto horizontal surfaces Three-phase linereactor Type b1 max . mm d1 mm D2 Mm d3 ...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/45 Version D MIDIMASTER output reactors** Order No. [MRPD] Enclos- ure size Curr- ent Voltage Weight 4EP3700-5DS FS4 50A 3-ph. 200V - 480V AC +/- 10% 3 . 3Kg MDV550/2 6SE6400-3TC02-8...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/48 3.15 MICROMASTER Vector braking resistors These braking resistors are used with the MICROMASTERVector drive inverters. They enable high inertia loads to bequickly decele...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 3/49 Version D 3.16 Electronic braking module (EBU) and braking resistors forMIDIMASTER Vector The kinetic energy of the motor and load is fed back into thedrive inverter when using th...
ENGINEERING INFORMATION AND INSTRUCTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 3/50 Time (s) 5 10 15 Permiss ible load for intermittent duty Permissible load for continuous duty 20 25 30 35 40 45 10% 50% 100% Resistor type A B D E Dimensions L x W x D (...
Communications / interfaces MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 4/0 4. Communications & interfaces 4/1 4.1 Communications, operator control and display elements 4/1 4.2 Standard operator panel 4/1 4.3 Serial RS485 interface 4/1 4.4 Control termin...
Communications / interfaces MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/1 Version C4 > empty page <
Communications / interfaces MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/2 Version C4 4. COMMUNICATIONS & INTERFACES 4.1 Communications, operator controland display elements MICROMASTER, MICROMASTER Vector andMIDIMASTER Vector have the identical operator control a...
Communications / interfaces MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/3 Version C4 Pin Function, information 1 Not assigned 2 Not assigned 3 RS485 send and receive data line, two-wire, positive differential input/output B/P 4 Not assigned 5 Reference potential, 0V ...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 4/4 The operator panel is automatically activated as soon as it isconnected to a drive inverter or the voltage is switched-on. Dimensions H x W x D 130 mm x 73 mm x 40 mm Current drain a...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/5 Version C4 The power supply specifications are as follows: Voltage tolerance 6V ± 0.5V Current drain for operation with a drive inverter: 50mA, Current drain for operation without drive inverte...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/7 Version C4 A segment can be extended by using RS485 amplifiers.Recommended: SINEC L2 amplifier for RS 485(Order No.: 6ES7972-0AA00-0XA0). In order to guarantee reliable operation of the serial ...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 4/8 4.7 CAN bus module CB16 The CAN bus module was developed for operation withMICROMASTER Vector / MIDIMASTER Vector and supports the CAN Open protocol. It fulfills therequirements of t...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/9 Version C3 4.10 Diagnostic functions, fault codes and parameter list The MICROMASTER, MICROMASTER Vector and MIDIMASTER Vector drive inverters have two alarm function stages: Warnings and Fault...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 4/10 4.11 Table of the fault and alarm codes Fault message Text 6SE32... 6SE92... Alarm Text 6SE32... 6SE92... F001 Overvoltage X X F002 Overcurrent X X W002 Current limit active X X F00...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 4/11 Version C3 4.12 Parameter list Legend: • = These parameters can also be changed while the drive inverter is operational. ²²² = The setting value depends on the drive inverter type. Parameter F...
COMMUNICATIONS / INTERFACES MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 4/14 Parameter Function Range [factory setting] MICROMASTER MICRO/MIDIMASTER Vector P212 • 100 % setpoint 0.00 - 100.00 [100.00] 0.00 - 100.00 [100.00] P220 Frequency cut-off 0 - 1 [0] 0...
DRIVE INVERTER SELECTION & ORDERING DATA MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 5/0 5 Drive inverter selection & ordering data 5.1 MICROMASTER/MICROMASTER Vector 5/1 5.2 MIDIMASTER Vector 5/3
DRIVE INVERTER SELECTION & ORDERING DATA MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 5/7 Version D MIDIMASTER Vector, 3-ph. 525 – 575V AC±15%, without filterIP56 (NEMA 4/12) Drive inverter Rated output current at 2) M = const. Rated output current at 1) 2) M ~ n² I...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 6/0 6 Options 6.1 Overview of the options 6/1 6.2 Ordering data, filters 6/2 6.3 Ordering data, reactors 6/8 6.4 Ordering data, brake resistors 6/15 6.5 Ordering data, braking modules 6/15 6.6 Recommended fu...
OPTIONEN MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 6/2 6. Options 6.1 Overview of the options Options Order No. MICROMASTER MICROMASTER Vector MIDIMASTER Vector Grounding strap forMM/MMV, Size A 6SE3290-0XX87-8FK0 Available Available - NEMA cable gland plat...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 6/3 Version D 6.2. Ordering data, filters 6.2.1 MICROMASTER & MICROMASTER Vector (1-ph 230V AC)* Ratedpower [KW ] Designation Drive inverterIP20/21 Order No. radio interferencesuppression filterClass A*Order No. r...
OPTIONEN MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 6/8 6.2.6 MIDIMASTER Vector (3-ph. 575V AC) Rated power [KW ] Designation Drive inverterIP21 Order No. Radio interferencesuppression filterClass A*Order No. Radio interferencesuppression filterClass B*Order...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 6/9 Version D 6.3. Ordering data, reactors 6.3.1 MICROMASTER & MICROMASTER Vector (1-ph 230V AC)* Ratedpower[KW ] Designation Drive inverterIP20/21Order No. line reactor 2%* Order No. line reactor 4% Order No. Out...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 6/13 Version D 6.3.6 MIDIMASTER Vector without integrated A filter (3-ph. 400V AC) Ratedpower[kW ] Designation IP21 Order No. 2% Line reactor* Order No. 4% Line reactor* Order No. Output reactor** Order No. 7.5 (CT)11...
OPTIONEN MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 6/14 6.3.7 MIDIMASTER Vector with integrated A filter (3-ph. 400V AC) Ratedpower[kW ] Designation IP21 Order No. 2% Line reactor* Order No. 4% Line reactor* Order No. Output reactor* Order No. 7.5 (CT)11 (V...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 6/15 Version D 6.3.8 MIDIMASTER Vector without integrated A filter (3-ph. 575V AC) Ratedpower[kW ] Designation Drive inverterIP21Order No. 2% Line reactor* Order No. 4% Line reactor* Order No. Output reactor** Order N...
OPTIONEN MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 Version D 6/16 6.5 Braking resistors for MICROMASTER Vector Electronic braking module (EBU) and braking resistors for MIDIMASTER Vector Braking resistors for MMV Resistor Continuous rated power Peak power Resistance ...
OPTIONS MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2002/2003 6/17 Version D 6.6 Recommended protection We recommend slow-acting line fuses to protect the feeder cable. The rule of thumb "input current (max. continuous current) ofthe drive inverter + ~30%" can be used to...
Appendix MICROMASTER MICROMASTER Vector MIDIMASTER Vector SIEMENS DA 64 – 2001/2002 Version C4 7/0 Information on COMBIMASTER, please refer to Catalogs DA64.8 and M11. Published byAutomation and Drives Group A&DStandard Drives Business DivisionPostfach 32 69, D-91050 ErlangenGermany Internet: ht...
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual