! DANGER DANGER indicates an imminently hazardous situation that, if not avoided, willresult in death or serious injury. DANGER is limited to the most extreme situations. ! WARNING WARNING indicates a potentially hazardous situation that, if not avoided, couldresult in death or serious injury, and/o...
MANUAL PUBLICATION HISTORY SIMATIC 505 PROFIBUS-FMS Communications Processor User Manual Order Manual Number: PPX:505–8129–1 Refer to this history in all correspondence and/or discussion about this manual. Event Date Description Original Issue 12/97 Original Issue (2807479–0001)
LIST OF EFFECTIVE PAGES Pages Description Pages Description Cover/Copyright Original History/Effective Pages Original iii — xiv Original 1-1 — 1-10 Original 2-1 — 2-12 Original 3-1 — 3-13 Original 4-1 — 4-13 Original 5-1 — 5-43 Original 6-1 — 6-39 Original 7-1 — 7-8 Original A-1 — A-18 Original B-1 ...
Contents iii Contents Preface Chapter 1 Overview 1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor Module 1-2 . . . . . . . . . . . . . . . Features 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
iv Contents 2.6 Powering Up the Base 2-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplying Power to the Base 2-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED S...
Contents v 4.3 FMS Services 4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FMS Connections 4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
vi Contents 5.7 Defining FDL Connections 5-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FDL Connections 5-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Contents vii 6.3 Example of a Send-Receive Job 6-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Tasks for a Send-Receive Job 6-14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Creating the Configuration...
viii Contents 7.5 FDL Connection Status 7-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing the Status of FDL Connections 7-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.6 Job Stat...
Contents ix List of Figures 1-1 Example of Devices on an FMS Network 1-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 The 505-CP5434-FMS Module 1-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 T...
Contents xi 6-16 Send Relay Ladder Logic for Station 1 6-23 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17 Receive Relay Ladder Logic for Station 5 6-25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18 Successful Tim...
xii Contents List of Tables 1-1 PROFIBUS Physical Parameters 1-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 LED Status Diagnostic Chart 2-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Preface xiii SIMATIC 505 PROFIBUS-FMS CP User Manual Preface This manual describes the SIMATIC 505 PROFIBUS-FMS CommunicationsProcessor module for the Series 505 programmable logic controller system.This manual also describes the COM5434 Configurator software package,which you use to create configur...
Preface xiv SIMATIC 505 PROFIBUS-FMS CP User Manual The following conventions are used in this manual: • “Click” means to place the mouse cursor on an object and quickly pressand release the mouse button. In most cases, only the left mouse buttonis used. • “Double-click” means to place the mouse cur...
Overview 1-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 1 Overview 1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor Module 1-2 . . . . . . . . . . . . . . . Features 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Overview 1-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor Module The SIMATIC 505 PROFIBUS-FMS Communications Processormodule (PPX:505-CP5434-FMS) provides an interface for 505-to-505communications, and between Series 505 programmable logic control...
Overview 1-3 SIMATIC 505 PROFIBUS-FMS CP User Manual The SIMATIC 505 PROFIBUS-FMS Communications Processor module iscompatible with all SIMATIC 545, 555, 565, and 575 CPUs. Any compatible programmable logic controllers or field devices equippedwith a PROFIBUS-FMS interface can participate on the net...
Overview 1-4 SIMATIC 505 PROFIBUS-FMS CP User Manual 1.2 Hardware Overview As shown in Figure 1-2, the bezel of the FMS CP module has four statusLEDs, a recessed RUN/STOP switch, a recessed RESET button, an RS-232port, and an RS-485 PROFIBUS-FMS port. RUN STOP FAULT RUN STOP RESET RS232 505-CP5434 -...
Overview 1-5 SIMATIC 505 PROFIBUS-FMS CP User Manual Below the LEDs is a recessed RUN/STOP toggle switch. The switch can bemoved from one position to another using a small tool, such as ascrewdriver. The switch is recessed to prevent accidental switching of themodule from one state to another. The R...
Overview 1-6 SIMATIC 505 PROFIBUS-FMS CP User Manual 1.3 Network Overview The Process Field Bus (PROFIBUS) standard (EN 50 170, Volume 2,PROFIBUS) defines the physical and logical parameters of a bit-serial busnetwork. PROFIBUS offers an interface for high-speed communicationswith field devices, as ...
Overview 1-7 SIMATIC 505 PROFIBUS-FMS CP User Manual The Open Systems Interconnection (OSI) 7 Layer Model defines levels ofcommunication from the physical layer to the logical layer. While the modelgives functions to the protocols, it does not define the protocols themselves.PROFIBUS-FMS uses layer ...
Overview 1-8 SIMATIC 505 PROFIBUS-FMS CP User Manual Network Overview (continued) PROFIBUS allows for multiple masters on a single network, where eachmaster can control the transmission of commands by holding a token. Thetoken is a special telegram that transfers the right of transmission from onema...
Overview 1-9 SIMATIC 505 PROFIBUS-FMS CP User Manual Communication on the PROFIBUS network can be described from both thephysical and the logical point of view. The physical view, as shown in Figure 1-5, describes a number of stationsconnected to a central bus line. This view emphasizes the actual p...
Overview 1-10 SIMATIC 505 PROFIBUS-FMS CP User Manual Network Overview (continued) Figure 1-7 shows how three stations on a network are configured tocommunicate. The arrows represent logical connections between thestations on the network. 505-CP5434 FMS CP Address 4 Connection 1 Remote Addr = 5 LSAP...
Installing the Module 2-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 2 Installing the Module 2.1 Overview of Installation 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow of Tasks 2-2 . . . . . . . . . . . . . . . . . . ....
Installing the Module 2-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.1 Overview of Installation Follow the flow of tasks shown in Figure 2-1 when installing the FMS CPmodule. Turn off power to the base. Cable your programming device to the FMS CP module using the RS-232 port. Power up the base. Check...
Installing the Module 2-3 SIMATIC 505 PROFIBUS-FMS CP User Manual ! CAUTION Electronic equipment is sensitive to, and can be damaged by, electrostaticdischarge. Ensure that personnel follow the precautions described below to avoiddamaging the FMS CP module by electrostatic discharge. Integrated circ...
Installing the Module 2-4 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.2 Setting the Baud Rate for the RS-232 Port A header labeled E1 is located on the module, as shown in Figure 2-2. Theheader determines the baud rate for the RS-232 port, and the jumper mustbe set before the module is installed in th...
Installing the Module 2-5 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.3 Inserting the FMS CP Module ! WARNING Electrical shock hazard is possible if you do not turn off all power to the basebefore attempting to insert the module. Failure to turn off power to the base could result in death or serious i...
Installing the Module 2-6 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.4 Connecting a Programming Device to the FMS CP Module The RS-232 port is the interface between your programming device, such asa personal computer (PC), and the FMS CP module. Using your PC and theRS-232 port, you can configure the...
Installing the Module 2-7 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.5 Connecting the FMS CP Module to the Network The PROFIBUS-FMS port is the interface between the FMS CP module andthe PROFIBUS network. To connect the FMS CP module to the network,use a standard 9-pin RS-485 cable that conforms to t...
Installing the Module 2-8 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.6 Powering Up the Base Refer to the system manual for your programmable logic controller forinformation on installing and wiring the power supply in the base. Followall installation guidelines and safety precautions described in you...
Installing the Module 2-9 SIMATIC 505 PROFIBUS-FMS CP User Manual The operating modes of the FMS CP module, which are indicated by theLED status, are defined below: • Startup: Power-up initialization is in progress. • Run: Normal operation. • Stopping: Stopping is a transition state and takes a few ...
Installing the Module 2-10 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.7 Configuring the I/O Address in the Programmable Logic Controller After installing the FMS CP module in the base, you need to register the I/Ostarting address of the FMS CP module in your programmable logiccontroller memory. The m...
Installing the Module 2-11 SIMATIC 505 PROFIBUS-FMS CP User Manual NOTE: Because discretes and words do not share the same image register addresses, the slot 02 entry in Figure 2-8 could be address 0001. I/O MODULE DEFINITION FOR CHANNEL . . . 1 BASE . . . 00 SLOT ADDRESS X Y WX WY FUNCTION I/O NUMB...
Installing the Module 2-12 SIMATIC 505 PROFIBUS-FMS CP User Manual 2.8 PROFIBUS Network Card and Software Packages You must install one of the PROFIBUS card/software packages listed inTable 2-2 on your PC in order to allow it to communicate with the FMS CPmodule on a PROFIBUS network. Consult the do...
Connecting the Network 3-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 3 Connecting the Network 3.1 Cables and Connectors 3-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PROFIBUS Cable 3-2 . . . . . . . . . . . . . . . . . . ....
Connecting the Network 3-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 3.1 Cables and Connectors This section describes products available from Siemens that are used to setup a PROFIBUS-FMS network. NOTE: Product availability is subject to change. To ensure that the cables, connectors, and repeaters you...
Connecting the Network 3-3 SIMATIC 505 PROFIBUS-FMS CP User Manual Standard cable connectors that conform to the PROFIBUS requirements areshown in Figure 3-2. The following standard cable connectors are availablefrom Siemens: • 6ES7 972-0BA10-0XA0 (for vertical connector without PG connector,9.6 Kbi...
Connecting the Network 3-4 SIMATIC 505 PROFIBUS-FMS CP User Manual Cables and Connectors (continued) A PROFIBUS repeater available from Siemens is shown in Figure 3-3. Therepeater connects two RS-485 segments, enabling expanded physicalnetworking. Nine repeaters may be used in a series. A standard P...
Connecting the Network 3-5 SIMATIC 505 PROFIBUS-FMS CP User Manual 3.2 Cable Routing Follow these suggestions when planning your cable routing. • Allow for system growth. Provide for attachment of future bases byrouting cable through all possible areas of plant expansion. • Take steps to bypass or e...
Connecting the Network 3-7 SIMATIC 505 PROFIBUS-FMS CP User Manual 3.3 Installing PROFIBUS Cables The PROFIBUS-FMS port provides communication over shielded twistedpair (RS-485) cable media. Figure 3-4 shows a sample system layout for the PROFIBUS network. Repeater SIMATIC S5 SIMATIC 575 SIMATIC S7-...
Connecting the Network 3-8 SIMATIC 505 PROFIBUS-FMS CP User Manual Installing PROFIBUS Cables (continued) Table 3-1 lists the PROFIBUS EN 50 170 cable line specifications. Table 3-1 PROFIBUS Cable Specifications Feature Specification Impedance 135 Ohm to 165 Ohm (3 MHz to 20 MHz) Capacitance 9.1 pF/...
Connecting the Network 3-9 SIMATIC 505 PROFIBUS-FMS CP User Manual The rules for proper PROFIBUS installation follow: • Create a daisy-chain arrangement, not a star arrangement. • You can connect up to 32 devices on one cable segment. Each repeatercounts as a device. • Do not run the cables near pow...
Connecting the Network 3-10 SIMATIC 505 PROFIBUS-FMS CP User Manual Installing PROFIBUS Cables (continued) The device at each extreme end of a PROFIBUS cable must be terminatedand biased; any connections made between segment ends must not beterminated or biased. See Figure 3-5. N = PROFIBUS-FMS stat...
Connecting the Network 3-11 SIMATIC 505 PROFIBUS-FMS CP User Manual Figure 3-7 shows the schematic for PROFIBUS connectors designed tohandle all baud rates, from 9600 baud to 12 Mbaud. Pin 6(BIAS SUPPLY +5V) Pin 5(BIAS SUPPLY GND) Pin 3(TX/RX+) Pin 8(TX/RX–) Termination Resistor, 220 ohm, 1/8 W, 5% ...
Connecting the Network 3-12 SIMATIC 505 PROFIBUS-FMS CP User Manual Installing PROFIBUS Cables (continued) The following procedure describes how to attach a Siemens PROFIBUSconnector to your cable. Also consult the instructions that come with yourspecific Siemens connector. 1. Open the connector hou...
Connecting the Network 3-13 SIMATIC 505 PROFIBUS-FMS CP User Manual 5. Remove 0.25 inches (6 mm) of insulation at the wire ends. 6. Insert the signal wires into the cable terminals. Be sure to connect the same wire color to the TX/RX+ pin for everydevice throughout your system. Crossing the wires at...
Communication Services 4-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 4 Communication Services 4.1 Overview 4-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication Services 4-2 . . . . . . . ...
Communication Services 4-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.1 Overview The FMS CP module supports the following types of communicationservices: • Fieldbus Message Specification (FMS) services are based on layer 7, theapplication layer of the OSI 7 Layer model. FMS services use anindustry-st...
Communication Services 4-3 SIMATIC 505 PROFIBUS-FMS CP User Manual Connections are the logical links between stations on the network. Youdefine connections for the FMS CP module using the COM5434Configurator. The FMS CP module supports the following connection types: • FMS connections • FDL connecti...
Communication Services 4-4 SIMATIC 505 PROFIBUS-FMS CP User Manual Overview (continued) The FMS CP module is registered in the I/O memory map of its controller asa 4 word input (WX) and 4 word output (WY) Special Function (SF) module.You must assign the starting I/O address, as described in Section ...
Communication Services 4-5 SIMATIC 505 PROFIBUS-FMS CP User Manual These bits are used to synchronize (handshake) communication between theuser program and the FMS CP module during communication jobs. • Th e Job Start Bit is a user-selected bit in one of the available output words (WY) assigned to t...
Communication Services 4-7 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.2 Addressing on Your Network PROFIBUS networks use a system of multiplexed addressing (multi-tiered)for connections, as shown in Figure 4-2. The most basic address of a deviceis the PROFIBUS network station address. The next level ...
Communication Services 4-8 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.3 FMS Services Before you configure an FMS communication job, you must first define anFMS connection using the COM5434 Configurator. To establish a successfulconnection, the services of the communication partners must be matched. A...
Communication Services 4-9 SIMATIC 505 PROFIBUS-FMS CP User Manual Figure 4-4 shows the data flow of each FMS communication job. Each FMScommunication job is configured in the shaded module. Read (name or index) Read response (data) Data Flow Local Station X FMS CP FMS CP CPU CPU Client Data to memo...
Communication Services 4-10 SIMATIC 505 PROFIBUS-FMS CP User Manual FMS Services (continued) When you define an FMS connection, you must specify access rights to thevariables you have configured (which are listed in the Object Dictionary).Access rights are determined in two ways: passwords and group...
Communication Services 4-11 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.4 Send-Receive Services Before you configure a Send-Receive job, you must first define an FDLconnection using the COM5434 Configurator. To define an FDL connection,follow the steps described in Section 5.7. The FMS CP module suppo...
Communication Services 4-12 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.5 Peerlink II Services Peerlink II is an unacknowledged broadcast service that allows the FMS CPmodule to transmit one peer block to other stations and receive up to 31peer blocks from other FMS CP modules on a scan-by-scan (cycli...
Communication Services 4-13 SIMATIC 505 PROFIBUS-FMS CP User Manual 4.6 S7 Services S7 services allow S7 devices to read and write data in the 505 CPU memory.The FMS CP module also responds to Status requests from an S7 station.S7 services supported by the FMS CP module are shown in Figure 4-8.Refer...
Using the COM5434 Configurator 5-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 5 Using the COM5434 Configurator 5.1 Installing the Software for the FMS CP Module 5-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Package 5-2 . . . . . . . . . . . . . . . . . ....
Using the COM5434 Configurator 5-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.1 Installing the Software for the FMS CP Module The COM5434 Configurator software package for the FMS CP module iscontained on two 3.5-inch disks. To run the COM5434 Configurator software, the operating system andhardware o...
Using the COM5434 Configurator 5-3 SIMATIC 505 PROFIBUS-FMS CP User Manual If you have successfully installed the COM5434 Configurator software, youcan start it in one of the following ways: • Double-click on the icon that appears on your Windows desktop. • Click the Start button to open the Windows...
Using the COM5434 Configurator 5-4 SIMATIC 505 PROFIBUS-FMS CP User Manual Installing the Software for the FMS CP Module (continued) 3. Select the port number that corresponds to the port on your PC, andselect the communications baud rate that matches the jumper settingon the module (see Section 2.2...
Using the COM5434 Configurator 5-5 SIMATIC 505 PROFIBUS-FMS CP User Manual Use the following procedure to configure your PC to communicate on aPROFIBUS network: 1. Select the menu command Transfer → Communications Setup... as shown in Figure 5-2. The first dialog allows you to select which portyou w...
Using the COM5434 Configurator 5-6 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.2 Features and Functions of the COM5434 Configurator Software To use all of the commands and features described in this chapter, you musthave installed the COM5434 Configurator software and connected your PCto the FMS CP mo...
Using the COM5434 Configurator 5-8 SIMATIC 505 PROFIBUS-FMS CP User Manual Features and Functions of the COM5434 Configurator Software (continued) Table 5-1 describes the functions of each of the menu commands of theCOM5434 Configurator software main screen. Table 5-1 Menu Commands Menu Commands Des...
Using the COM5434 Configurator 5-9 SIMATIC 505 PROFIBUS-FMS CP User Manual Table 5-1 Menu Commands (continued) Menu Commands Description Options ✔ Validate Page After Edits ✔ Automatically Generate Names Automatically Generate Names automatically generates unique names for each new itemname field. V...
Using the COM5434 Configurator 5-10 SIMATIC 505 PROFIBUS-FMS CP User Manual Features and Functions of the COM5434 Configurator Software (continued) The toolbar, located below the menu bar, consists of buttons which duplicatefrequently used menu commands. A tool tip displays the name of eachbutton wh...
Using the COM5434 Configurator 5-11 SIMATIC 505 PROFIBUS-FMS CP User Manual When your mouse cursor is on an item in the configuration tree, you canclick the right mouse button to call up a pop-up menu. This menu duplicatesmost of the commands on the Edit menu. With the mouse cursor in a dataentry fi...
Using the COM5434 Configurator 5-12 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.3 Describing the Configuration File ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Current configuration file specification Module Local Configuration FMS Connections FDL Connections Communication Jobs FM...
Using the COM5434 Configurator 5-13 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.4 Defining the Module Local Configuration The module local configuration, shown in Figure 5-8, identifies the localstation address where the FMS CP module resides and defines thecommunication parameters used by the FMS net...
Using the COM5434 Configurator 5-14 SIMATIC 505 PROFIBUS-FMS CP User Manual Defining the Module Local Configuration (continued) Highest Station Address Use the drop-down list to select the value that is equal to or greater than the highest PROFIBUS network stationaddress in use on your network. This...
Using the COM5434 Configurator 5-15 SIMATIC 505 PROFIBUS-FMS CP User Manual NOTE: If you customize the Bus Parameter Profile by selecting Custom in the Bus Parameter Profile field and changing values in any of the fieldsbelow, every device on your network must have the same or a compatibleprofile. O...
Using the COM5434 Configurator 5-16 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.5 Defining Peerlink II Services The FMS CP module supports a maximum of 32 Peerlink II services, asshown in Figure 5-9. The FMS CP module transmits and receives data (inthe form of peer blocks) to and from other SIMATIC 50...
Using the COM5434 Configurator 5-17 SIMATIC 505 PROFIBUS-FMS CP User Manual ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Configured cyclic data blocks sent/received to/from other 505-CP5434-FMS modules Module Local Configuration FMS Connections FDL Connections Communication Jobs ...
Using the COM5434 Configurator 5-18 SIMATIC 505 PROFIBUS-FMS CP User Manual Defining Peerlink II Services (continued) Peer Block Type Select either Receive or Transmit for each peer block. (Remember that each FMS CP module supports only one transmitblock and up to 31 receive blocks.) Local Address E...
Using the COM5434 Configurator 5-19 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.6 Defining FMS Connections The FMS CP module supports up to 32 FMS connections, as shown inFigure 5-12. ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Links to other Fieldbus Message Specification (FMS) d...
Using the COM5434 Configurator 5-22 SIMATIC 505 PROFIBUS-FMS CP User Manual Defining FMS Connections (continued) Access Groups When you click on the Access Groups field, a button appears in the field. Click on the button to view the Access GroupRights dialog box (shown in Figure 5-14). Select the gr...
Using the COM5434 Configurator 5-23 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.7 Defining FDL Connections The FMS CP module supports up to 32 FDL connections, as shown inFigure 5-16. FDL connections are used for Send-Receive jobs. ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Links...
Using the COM5434 Configurator 5-25 SIMATIC 505 PROFIBUS-FMS CP User Manual Local LSAP Enter a numeric value for the local Link Service Access Point for the FDL connection on the local module. Choose a valuebetween 2 and 33. You cannot use the same local LSAP more than once. Remote LSAP Enter a nume...
Using the COM5434 Configurator 5-26 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.8 Overview of Communication Jobs The FMS CP module supports a maximum of 48 communication jobs, asshown in Figure 5-18. When you click on Communication Jobs on theconfiguration tree, the COM5434 Configurator displays the n...
Using the COM5434 Configurator 5-27 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.9 Configuring FMS Jobs Before you can configure an FMS job, you must have defined an FMSconnection between the local FMS CP module and the remote device (seeSection 5.6). Click on FMS Jobs on the configuration tree to see ...
Using the COM5434 Configurator 5-29 SIMATIC 505 PROFIBUS-FMS CP User Manual Job Type Select Read, Write, Information Report, Status, or Identify from the drop-down list. (See Section 4.3 for descriptions of the FMS jobtypes.) Connection Select an FMS connection that you have previously defined in th...
Using the COM5434 Configurator 5-30 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.10 Configuring Send-Receive Jobs Before you can configure a Send-Receive job, you must have defined an FDLconnection between the local FMS CP module and the remote device (seeSection 5.7). The FMS CP module supports 48 com...
Using the COM5434 Configurator 5-32 SIMATIC 505 PROFIBUS-FMS CP User Manual Configuring Send-Receive Jobs (continued) Job Type Select Send or Receive from the drop-down list. FDL Connection Select an FDL connection that you have previously defined. The COM5434 Configurator automatically lists yourco...
Using the COM5434 Configurator 5-33 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.11 Creating FMS Data Types The FMS CP module supports up to 85 FMS data types. You can construct auser data type to hold a combination of information types, and then define avariable that uses that special data type. Click...
Using the COM5434 Configurator 5-34 SIMATIC 505 PROFIBUS-FMS CP User Manual Creating FMS Data Types (continued) ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Reference name given to this job (must be unique) Edit Module Local Configuration FMS Connections FDL Connections Communica...
Using the COM5434 Configurator 5-35 SIMATIC 505 PROFIBUS-FMS CP User Manual Definition When you click on the Definition field, a button appears. Click on the button to bring up the User Data Type Editor dialog box(shown in Figure 5-27). Use the drop-down list of available data typestogether with the...
Using the COM5434 Configurator 5-36 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.12 Creating FMS Variables The FMS CP module supports up to 100 FMS variables. Click on FMS Variables on the configuration tree to see the number ofvariables available, as shown in Figure 5-28. ✂ File Edit Transfer Options ...
Using the COM5434 Configurator 5-37 SIMATIC 505 PROFIBUS-FMS CP User Manual ✂ File Edit Transfer Options Diagnostics Help Untitled – COM5434 Reference name of this variable Edit Module Local Configuration FMS Connections FDL Connections Communication Jobs FMS Jobs Send-Receive Jobs FMS Data Types FM...
Using the COM5434 Configurator 5-38 SIMATIC 505 PROFIBUS-FMS CP User Manual Creating FMS Variables (continued) PLC Memory When you click on the PLC Memory field, a button appears in the field. Click on the button to view the PLC Memory TypeEditor dialog box (shown in Figure 5-30). Select a PLC memor...
Using the COM5434 Configurator 5-39 SIMATIC 505 PROFIBUS-FMS CP User Manual Access Groups When you click on the Access Groups field, a button appears in the field. Click on the button to view the Variable AccessGroups dialog box (shown in Figure 5-32). Define which groups canhave access to the varia...
Using the COM5434 Configurator 5-40 SIMATIC 505 PROFIBUS-FMS CP User Manual Creating FMS Variables (continued) Use Index? Select Yes to specify that the Information Report is to be stored as an index, or select No to store it by name. Sub Index You can specify an element number if the variable is an...
Using the COM5434 Configurator 5-41 SIMATIC 505 PROFIBUS-FMS CP User Manual 5.13 Saving and Downloading the Configuration You can save your configuration to a file before you download the file to theFMS CP module. To save a configuration, follow these steps: 1. To ensure that all configuration param...
Using the COM5434 Configurator 5-42 SIMATIC 505 PROFIBUS-FMS CP User Manual Saving and Downloading the Configuration (continued) It is always a good practice to produce and archive accurate documentationfor each configuration. A printed record of your configuration is one way todo this. To print the...
Configuration Examples 6-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 6 Configuration Examples 6.1 Overview 6-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 Example of an FMS Read Job 6-4 . . . ...
Configuration Examples 6-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 6.1 Overview This chapter describes how to define connections and jobs for the FMS CPmodule using the COM5434 Configurator. Several configuration examplesare provided. The configuration examples are based on the example networkshown ...
Configuration Examples 6-3 SIMATIC 505 PROFIBUS-FMS CP User Manual Figure 6-2 shows the configuration tasks you must complete to configure theFMS CP module using the COM5434 Configurator. Configure the local FMS CP module using the COM5434 Configurator. Create and name the configuration file. Define...
Configuration Examples 6-4 SIMATIC 505 PROFIBUS-FMS CP User Manual 6.2 Example of an FMS Read Job Figure 6-3 shows the flow of data during an FMS Read job configuredbetween Station 1 (FMS CP) and Station 2 (FMS CP) on the examplenetwork. Station 1 is the client and initiates the request for data. St...
Configuration Examples 6-5 SIMATIC 505 PROFIBUS-FMS CP User Manual The first step in the process is to create the configuration file. Click on thetop icon of the configuration tree, which says <no description> . Then enter a description for this file in the Description field, as shown below an...
Configuration Examples 6-6 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of an FMS Read Job (continued) Next, you must define the Module Local Configuration of the FMS CPmodule for Station 1. 1. Click on the Module Local Configuration icon. 2. Complete the fields listed below (and shown in Figure ...
Configuration Examples 6-7 SIMATIC 505 PROFIBUS-FMS CP User Manual Continue configuring the FMS Read job by defining the FMS connection forthe FMS CP module at Station 1. 1. Click on the FMS Connections icon of the configuration tree. 2. Click on the New Item button on the toolbar. 3. Complete the f...
Configuration Examples 6-8 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of an FMS Read Job (continued) Once you have defined the Module Local Configuration and the FMSconnection, you can configure the FMS Read job for Station 1. 1. Click on the FMS Jobs icon on the configuration tree. 2. Click on...
Configuration Examples 6-9 SIMATIC 505 PROFIBUS-FMS CP User Manual Save your file to disk before attempting to transfer the file to the FMS CPmodule. Follow these steps: 1. Select the menu command File → Save As... or click on the Save button: 2. Select a directory to store the saved file. 3. Enter ...
Configuration Examples 6-10 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of an FMS Read Job (continued) After you configure the FMS Read job for Station 1, you need to create aconfiguration file for Station 2 by following these steps: 1. Select the menu command File → New to create an empty confi...
Configuration Examples 6-11 SIMATIC 505 PROFIBUS-FMS CP User Manual Continue configuring the FMS Read job by defining an FMS variable for theFMS CP module at Station 2. 1. Click on the FMS Variables icon of the configuration tree. 2. Click on the New Item button on the toolbar. 3. Complete the field...
Configuration Examples 6-13 SIMATIC 505 PROFIBUS-FMS CP User Manual C99 BITP1 A: WX1N=2 C99 C100 C99 BITP1 And BITP2 verify that no previous jobs are in progress prior tosetting the Read Job Start Bit. C21 BITP2 A: WY5N=2 BITC1 A: WY5N=2 C22 BITS1 A: WY5N=2 C23 C100 C21 After the Read Job Start Bit ...
Configuration Examples 6-14 SIMATIC 505 PROFIBUS-FMS CP User Manual 6.3 Example of a Send-Receive Job Figure 6-11 shows the flow of data during Send-Receive jobs configuredbetween Station 1 (FMS CP) and Station 5 (FMS CP) on the examplenetwork. Station 1 sends the data. Station 5 receives the data f...
Configuration Examples 6-15 SIMATIC 505 PROFIBUS-FMS CP User Manual The first step in the process is to create the configuration file. 1. Select the menu command File → New to create an empty configuration file. 2. Enter a description for this file in the Description field, as shown below(and in Fig...
Configuration Examples 6-17 SIMATIC 505 PROFIBUS-FMS CP User Manual Continue configuring the Send job for Station 1 by defining the FDLconnection for the FMS CP module at Station 1. 1. Click on the FDL Connections icon of the configuration tree. 2. Click on the New Item button on the toolbar. 3. Com...
Configuration Examples 6-18 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Send-Receive Job (continued) Once you have defined the Module Local Configuration and the FDLconnection, you can configure a Send job for Station 1. 1. Click on the Send-Receive Jobs icon of the configuration tree. 2. C...
Configuration Examples 6-21 SIMATIC 505 PROFIBUS-FMS CP User Manual Once you have defined the Module Local Configuration and the FDLconnection, you can configure a Receive job for Station 5. 1. Click on the Send-Receive Jobs icon of the configuration tree. 2. Click on the New Item button on the tool...
Configuration Examples 6-22 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Send-Receive Job (continued) After you successfully load the configuration files to both programmablelogic controller stations, you must add RLL coding to the RLL programs ofboth programmable logic controllers to activa...
Configuration Examples 6-23 SIMATIC 505 PROFIBUS-FMS CP User Manual C98 Xn MOVW1 A: 1B:V300N=1 Enabling Rung (User Logic) C43 C30 C98 A: WY5N=1 C101 BITP3 A: WX1N=3 BITP4 A: WY5N=3 C41 C35 C98 C27 C28 C101 C41 C98 BITC3 A: WY5N=3 C42 C101 C41 BITS2 A: WY5N=3 C43 C101 C41 C30 CMP1 A: V15B:V300 LT:C26...
Configuration Examples 6-24 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Send-Receive Job (continued) The Relay Ladder Logic example in Figure 6-17 demonstrates a typicalscenario for enabling a Receive acknowledgement. This section assumesthat you are familiar with Series 505 programmable lo...
Configuration Examples 6-25 SIMATIC 505 PROFIBUS-FMS CP User Manual C49 MOVW1 A: 1B:V302N=3 C33 C40 C49 C50 BITP1 A: WX3N=3 BITP2 A: WY7N=3 C31 C45 C49 C37 C38 C50 C31 C49 BITC1 A: WY7N=3 C32 C50 C31 BITS1 A: WY7N=3 C33 C50 C31 C40 CMP1 A: V25B:V302 LT:C36GT:C37 C49 C38 C37 C36 Communication Interlo...
Configuration Examples 6-26 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Send-Receive Job (continued) Figure 6-18 shows the sequence of events for a successful FDL transaction. WY5.3 t0 t2 WX1.3 t1 t3 t4 SEND RECEIVE t6 t5 WX3.3 t8 WY7.3 t7 Figure 6-18 Successful Timing Example The list belo...
Configuration Examples 6-27 SIMATIC 505 PROFIBUS-FMS CP User Manual Figure 6-19 shows the sequence of events for an unsuccessful FDLtransaction. WY5.3 WX1.3 t2 t4 SEND RECEIVE WY7.3 t3 WX3.3 t1 t0 t5 a Figure 6-19 Unsuccessful Timing Example The list below explains the sequence of events. t0 Send jo...
Configuration Examples 6-28 SIMATIC 505 PROFIBUS-FMS CP User Manual 6.4 Example of a Peerlink II Transmit and Receive Service Figure 6-20 shows Transmit and Receive services between two stations.Using the COM5434 Configurator, configure these Peerlink II Services bycompleting the following tasks: Cr...
Configuration Examples 6-29 SIMATIC 505 PROFIBUS-FMS CP User Manual The first step in the process is to create the configuration file for Station 1. 1. Select the menu command File → New to create an empty configuration file. 2. Enter a description for this file in the Description field, as shown be...
Configuration Examples 6-30 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Peerlink II Transmit and Receive Service (continued) Next, you must define the Module Local Configuration of the FMS CPmodule for Station 1. 1. Click on the Module Local Configuration icon. 2. Complete the fields listed...
Configuration Examples 6-31 SIMATIC 505 PROFIBUS-FMS CP User Manual Once you have defined the Module Local Configuration, you can configurethe peer transmit interval and priority factor, (as shown in Figure 6-23). 1. Click on the Peerlink II Services icon of the configuration tree. 2. Enter the para...
Configuration Examples 6-32 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Peerlink II Transmit and Receive Service (continued) 3. Click on the New Item button on the toolbar. 4. Complete the fields listed below (and shown in Figure 6-24) toconfigure the Peerlink II Transmit service: Peer Job ...
Configuration Examples 6-33 SIMATIC 505 PROFIBUS-FMS CP User Manual Continue by configuring the parameters for a Receive service. 1. Click on the New Item button on the toolbar. 2. Complete the fields listed below to configure the Receive service: Peer Job Name: Red Box Count Descriptor ID: 2 Peer J...
Configuration Examples 6-34 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Peerlink II Transmit and Receive Service (continued) The second step in the process is to create the configuration file forStation 5. 1. Select the menu command File → New to create an empty configuration file. 2. Enter...
Configuration Examples 6-37 SIMATIC 505 PROFIBUS-FMS CP User Manual 3. Click on the New Item button on the toolbar. 4. Complete the fields listed below (and shown in Figure 6-28) toconfigure the Peerlink II Transmit service: Peer Job Name: Red Box Count Descriptor ID: 2 Peer Job Type: Transmit Local...
Configuration Examples 6-38 SIMATIC 505 PROFIBUS-FMS CP User Manual Example of a Peerlink II Transmit and Receive Service (continued) Continue by configuring the parameters for a Receive service. 1. Click on the New Item button on the toolbar. 2. Complete the fields listed below (and shown in Figure...
Diagnostics 7-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Chapter 7 Diagnostics 7.1 CP Status 7-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing the Status of the FMS CP Module 7-2 . . . . . . . . . ...
Diagnostics 7-2 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.1 CP Status The Read CP Status dialog provides useful information on the operatingstatus of the module. To view this information, select the menu commandDiagnostics → CP Status. The Read CP Status dialog appears, as shown in Figure 7-1. Updat...
Diagnostics 7-3 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.2 Active Stations The List of Active Stations dialog lists all stations on the bus and thecurrent status of each. To view this information, select the menu commandDiagnostics → Active Stations. The List of Active Stations dialog appears, as s...
Diagnostics 7-4 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.3 PROFIBUS Statistics The PROFIBUS Statistics dialog provides statistical information about thestatus of the PROFIBUS communications. To view this information, selectthe menu command Diagnostics → PROFIBUS Statistics. The PROFIBUS dialog appe...
Diagnostics 7-5 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.4 FMS Connection Status The List of FMS Connections dialog lists the existing configured FMSconnections and the current status of each. To view this information, selectthe menu command Diagnostics → FMS Connection Status. The List of Configur...
Diagnostics 7-6 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.5 FDL Connection Status The List of FDL Connections dialog lists the existing configured FDLconnections and the current status of each. To view this information, selectthe menu command Diagnostics → FDL Connection Status. The List of Configur...
Diagnostics 7-7 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.6 Job Status The List of FMS/Send-Receive Jobs dialog lists the existing FMS jobs andSend-Receive jobs and the status of each. To view this information, selectthe menu command Diagnostics → Job Status. The List of Configured FMS/Send-Receive ...
Diagnostics 7-8 SIMATIC 505 PROFIBUS-FMS CP User Manual 7.7 Peer Block Status The List of Configured Peer Blocks dialog lists the existing configured PeerBlocks and the current status of each. To view this information, select themenu command Diagnostics → Peer Block Status. The List of Configured Pe...
Reference Data A-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Appendix A Reference Data A.1 Data Element List A-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SIMATIC 505 Data Types and S7 Addressing A-2 . . . . . . . . . ...
Reference Data A-2 SIMATIC 505 PROFIBUS-FMS CP User Manual A.1 Data Element List Table A-1 shows the allowed data types (elements) for local or remoteSIMATIC 505 PLCs. It also shows the SIMATIC S7 data type to use whenaccessing a Series 505 PLC from an S7 PLC. Table A-1 Data Element List Data Elemen...
Reference Data A-5 SIMATIC 505 PROFIBUS-FMS CP User Manual Table A-1 Data Element List (continued) Data Element Description Notes Name PLC TT Access PLC Representation S7 Area (DB=84H) S7 Subarea Hex (Dec) GO (Application O global Variables) 5 GO E0 r/w integer DB E0 (224) GN (Application N global V...
Reference Data A-6 SIMATIC 505 PROFIBUS-FMS CP User Manual A.2 Data Access between SIMATIC S7 and SIMATIC 505 Systems Variables in the SIMATIC 505 system are addressed sequentially startingfrom 1 regardless of the data size, and the quantity of data is measured inmultiples of the variable size. For ...
Reference Data A-7 SIMATIC 505 PROFIBUS-FMS CP User Manual To derive the SIMATIC S7 address for a SIMATIC 505 variable, use thefollowing steps: 1. Subtract 1 from the 505 address; (for example, V2, 1 becomes V1, 1). 2. Multiply the 505 address by the number of bytes in the 505 variable;(V1, 1 become...
Reference Data A-8 SIMATIC 505 PROFIBUS-FMS CP User Manual A.3 Mapping of FMS Variables onto 505 Memory Figure A-2 shows examples of how simple variables are mapped inSIMATIC 505 V-memory. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 * * * * * * * X * Boolean A Boolean is rounded up to an even byte length...
Reference Data A-9 SIMATIC 505 PROFIBUS-FMS CP User Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X Time Difference 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 05 Visible String5 1 A Visible String is preceded by two bytes which record the length of the string. The first byte isthe maximum length of th...
Reference Data A-10 SIMATIC 505 PROFIBUS-FMS CP User Manual Mapping of FMS Variables onto 505 Memory (continued) Figure A-3 shows how variable arrays are mapped in SIMATIC 505 memory. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 * * * * * * X1 Array[10] of Boolean An array of Boolean is rounded up to an e...
Reference Data A-11 SIMATIC 505 PROFIBUS-FMS CP User Manual Figure A-4 shows how an example structure of data types is mapped inSIMATIC 505 memory. STRUCT{ (A) Boolean (B) Boolean (C) Unsigned8 (D) Unsigned8 (E) Boolean (F) Integer16 (G) Integer16 (H) Integer32 (I) Unsigned8 (J) Unsigned16 (K) Unsig...
Reference Data A-12 SIMATIC 505 PROFIBUS-FMS CP User Manual Mapping of FMS Variables onto 505 Memory (continued) The FMS Status request function allows status information to be requestedfrom the communications partner on the specified FMS connection. Thefollowing information is available in the resp...
Reference Data A-13 SIMATIC 505 PROFIBUS-FMS CP User Manual The FMS Identify request function allows the following information to beobtained from the partner device: • Name of the device vendor (vendor name) • Name or model number of the device • Revision (or version) of the device Figure A-6 shows ...
Reference Data A-14 SIMATIC 505 PROFIBUS-FMS CP User Manual A.4 Protocol Implementation Conformance Statements (PICS) The Protocol Implementation Conformance Statements (PICS) providefurther information about the implementation of FMS (range andcomplexity) on the FMS CP module. This information is r...
Reference Data A-15 SIMATIC 505 PROFIBUS-FMS CP User Manual Table A-6 PICS Part 3: FMS Parameters and Options FMS Parameters and Options Detail Addressing by name YES Maximum length for names 32 Access protection supported — Maximum length for extension 32 Maximum length for extension arguments 0 Ta...
Reference Data A-16 SIMATIC 505 PROFIBUS-FMS CP User Manual A.5 FMS Connection Types and Variables When configuring FMS connections, you must specify the connection type.Table A-8 shows which job types are available for data transfer with eachconnection type. Table A-8 FMS Connection Types and Jobs ...
Reference Data A-17 SIMATIC 505 PROFIBUS-FMS CP User Manual You can enable and disable read or write access to each variable in yourconfiguration. The Access Rights dialog in the FMS Variable input paneallows you to specify read or write access by password, by groups, or by all.The effects of these ...
Reference Data A-18 SIMATIC 505 PROFIBUS-FMS CP User Manual A.6 Local LSAP Assignments Table A-10 lists the available LSAP assignment numbers and anyrestrictions that may apply. Table A-10 Local LSAP Assignments LSAP Conditions 0, 1 Reserved 2 to 33 2 to 52 Available for FDL connections Available fo...
Troubleshooting B-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Appendix B Troubleshooting B.1 Using the RESET Button B-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B.2 Job Status Codes B-3 . . . . . . . . . . . . . . . . . . . ....
Troubleshooting B-3 SIMATIC 505 PROFIBUS-FMS CP User Manual B.2 Job Status Codes Table B-1 lists the status codes and their meanings for FMS orSend-Receive jobs. Table B-1 FMS or Send-Receive Job Status Error Description 0000 Job executed successfully; no errors. D000 Job not yet triggered by WY bit...
Troubleshooting B-5 SIMATIC 505 PROFIBUS-FMS CP User Manual Table B-3 lists FMS job error codes signaled by the communication partner. Table B-3 Errors Signaled by the FMS Partner Error Description 8200 Unspecified application reference error. 8201 Application (for example, user program) not obtaina...
Troubleshooting B-6 SIMATIC 505 PROFIBUS-FMS CP User Manual Job Status Codes (continued) Table B-4 lists the error codes and their meanings for Send-Receive jobs. Table B-4 Send-Receive Job Error Codes Error Description E0E0 Receive Job: no data available. This error occurs when a Receive jobis exec...
Troubleshooting B-7 SIMATIC 505 PROFIBUS-FMS CP User Manual B.3 CP-to-Controller Status Codes Table B-5 CP-to-Attached Controller Error Codes for FMS and Send-Receive Jobs Status Code (Hex) Description 80xx xx is task code error response from attached PLC; see PLC documentation. These errorsusually ...
Specifications C-1 SIMATIC 505 PROFIBUS-FMS CP User Manual Appendix C Specifications Table C-1 Communication Capacities Communication Type Maximum Number or Size FMS Connections 32 FDL Connections 32 S7 Connections 48 Total number of connections 59 (or 60 if Peerlink service is not used) FMS variabl...
Index-1 Index A Access groups, 5-22, 5-39 Access rights, 5-38 Active stations status, 7-3 Addressing, network, 4-7 Agency approvals, xiv, C-2 Arrays examples, A-10number of elements, 5-39 Assistance, technical, xiv B Base, powering up, 2-8–2-9 Baud rate selecting for local module, 5-14setting RS-232...
Customer Response We would like to know what you think about our user manuals so that we can serve you better.How would you rate the quality of our manuals? Excellent Good Fair Poor AccuracyOrganizationClarityCompletenessGraphicsExamplesOverall designSizeIndex Would you be interested in giving us mo...
BUSINESS REPLY MAIL FIRST CLASS PERMIT NO.3 JOHNSON CITY, TN FOLD FOLD POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES ATTN TECHNICAL COMMUNICATIONS M/S 519SIEMENS ENERGY & AUTOMATION INC PO BOX 1255JOHNSON CITY TN 37605–1255 SIEMENS ENERGY & AUTOMATION ...
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual