Siemens E-110 – User Manual in PDF format online.
Manuals:
User Manual Siemens E-110
Summary
SINAMICS G110 120 W - 3 kW Operating Instructions User Documentation Inverter Type SINAMICS G110 Firmware Version 1.0 &1.1 (See Page 4) Issue 04/2005 Overview 1 Installation 2 Commissioning 3 Using the SINAMICS G110 4 System Parameters 5 Troubleshooting 6 Specifications 7 Options 8 Electro-Magne...
SINAMICS G110 Operating Instructions 4 6SL3298-0AA11-0BP0 Summary of Amendments Edition Valid for firmware version Status/Changes Order no of the inverter 6SL3211-0xxxx-xxxx 04/2003 1.0 First issue Last digit “0” 6SL3211-0xxxx-xxx 0 11/2004 1.0 1.1 New features inserted: Types of Control using the T...
04/2005 Important Information SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 5 Important Information WARNING Before installing and commissioning the inverter, you must read all safety instructions and warnings carefully including all the warning labels attached to the equipment. Make sure t...
Definitions 04/2005 SINAMICS G110 Operating Instructions 6 6SL3298-0AA11-0BP0 Definitions DANGER For the purpose of this documentation and the product warning labels, “Danger” indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING For the p...
04/2005 Safety Instructions SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 7 Safety Instructions The following Warnings, Cautions and Notes are provided for your safety and as a means of preventing damage to the product or components in the machines connected. This section lists Warnings, C...
Safety Instructions 04/2005 SINAMICS G110 Operating Instructions 8 6SL3298-0AA11-0BP0 Transport & Storage WARNING Correct transport, storage, erection and mounting, as well as careful operation and maintenance are essential for proper and safe operation of the equipment. CAUTION Protect the inve...
04/2005 Safety Instructions SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 9 Operation WARNINGS ¾ SINAMICS G110 inverters operate at high voltages. ¾ When operating electrical devices, it is impossible to avoid applying hazardous voltages to certain parts of the equipment. ¾ Emergency Stop ...
04/2005 Overview SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 11 Table of Contents 1 Overview ................................................................................................................ 15 1.1 The SINAMICS G110 ............................................................
04/2005 Overview SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 13 List of Illustrations Figure 2-1 Reforming Capacitors After a Period of Storage .................................................................. 19 Figure 2-2 Derating for Altitude ............................................
04/2005 Overview SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 15 1 Overview 1.1 The SINAMICS G110 The SINAMICS G110s are a range of frequency inverters for controlling the speed of three phase AC motors, incorporating the CPM 110 controlled power module. The various models available range...
Overview 04/2005 SINAMICS G110 Operating Instructions 16 6SL3298-0AA11-0BP0 Performance Characteristics ¾ Fast repeatable response time to control signals ¾ Fast Current Limitation (FCL) for trip-free operation ¾ Built-in DC injection brake ¾ Compound braking ¾ Fixed Frequencies ¾ Motor potentiomete...
04/2005 Installation SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 17 2 Installation WARNINGS ¾ Work on the device/system by unqualified personnel or failure to comply with warnings can result in severe personal injury or serious damage to material. Only suitably qualified personnel traine...
Installation 04/2005 SINAMICS G110 Operating Instructions 18 6SL3298-0AA11-0BP0 The serial numbers consist 13 characters and contains the date of manufacture, e.g. XAP214-123456 XA P214-123456 Characters 1-2 are the site where the product is built XA P 214-123456 Character 3 denotes the year e.g. R ...
04/2005 Installation SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 19 Atmospheric Pollution Do not install the inverter in an environment, which contains atmospheric pollutants such as dust, corrosive gases, etc. Water Take care to site the inverter away from potential water hazards, e.g. ...
Installation 04/2005 SINAMICS G110 Operating Instructions 20 6SL3298-0AA11-0BP0 2.8 Mechanical Installation WARNING ¾ To ensure the safe operation of the equipment, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in these operating instruct...
04/2005 Installation SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 23 2.9 Electrical Installation WARNING ¾ To ensure the safe operation of the equipment, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in these operating instruct...
Installation 04/2005 SINAMICS G110 Operating Instructions 24 6SL3298-0AA11-0BP0 Operation with Residual Current Device If an RCD (also referred to as ELCB or RCCB) is fitted, the SINAMICS G110 inverters will operate without nuisance tripping, provided that: ¾ A type B RCD is used. ¾ If the SINAMICS ...
04/2005 Installation SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 25 Access to the power and motor terminals Figure 2-5 below show the layout of the SINAMICS G110 inverter’s control, power and motor connection terminals. Figure 2-5 SINAMICS G110 Connection Terminals Figure 2-6 SINAMICS G1...
Installation 04/2005 SINAMICS G110 Operating Instructions 26 6SL3298-0AA11-0BP0 On FSA to access the DC+/DC- terminals the cutout cover must be removed using a small pair of cutters, ensuring that no plastics from the cutout fall into the inverter housing (see Figure 2-6 on page 25). The terminal co...
04/2005 Installation SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 29 2.10 SINAMICS G110 Flat Plate Variant The SINAMICS G110 Flat Plate variant has been designed to allow greater flexibility in the installation of the inverter by an advanced user as an individual unit or as part of an aut...
Installation 04/2005 SINAMICS G110 Operating Instructions 30 6SL3298-0AA11-0BP0 ♦ Free from dents and holes. ♦ Made of metal (steel or aluminium). ♦ Must not be painted. ♦ Must be free from rust. 5. Apply coating of heatsink/thermal contact paste to the inverter’s flat plate. 6. Ensure that the cont...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 31 3 Commissioning This section describes the different methods of how to commission and run the SINAMICS G110 inverter. A prerequisite is that the mechanical and electrical installation has been completed as described in ...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 33 3.2 Commission Modes Basic commissioning of the SINAMICS G110 Inverter can be performed by using one of the following methods which are suitable for a large range of applications: ¾ Using the inverter with its factory d...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 34 6SL3298-0AA11-0BP0 3.3 Basic Commissioning The SINAMICS G110 is supplied with default parameter settings to cover the following basic operation: ¾ The motor rating data; voltage, current and frequency data has already been keyed into the ...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 35 3.3.1 Factory Settings The inverter has already been programmed at the factory for standard V/f applications on a Siemens standard four-pole 3-phase induction motor, that has the same power rating as the inverters. Cont...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 36 6SL3298-0AA11-0BP0 Controlling the speed of the motor is accomplished on the Analog variant by connecting a potentiometer ( ≥ 4.7 k Ω ) to the analog input (external switches and potentiometers are not supplied with the inverter) or via t...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 37 Bus termination on USS variant The USS variant of the SINAMICS G110 inverter uses RS485 protocols to communicate with the controlling system and all other inverters connected to the network. It is necessary to terminate...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 38 6SL3298-0AA11-0BP0 Changing parameters with the Basic Operator Panel The description below serves as an example that shows how to change any parameters using the BOP. These examples can also be used as a guide to configuring the inverter ...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 39 NOTE In some cases - when changing parameter values - the display on the BOP shows . This means the inverter is busy with tasks of a higher priority. Changing single digits in parameter values For changing the parameter...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 40 6SL3298-0AA11-0BP0 Note The speed reading on the BOP is correct if a Siemens standard 4-pole 3-phase induction motor is connected. Otherwise the motor rated speed has to be changed (see Section 3.4.4 on page 46). Warning and fault status ...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 42 6SL3298-0AA11-0BP0 The SINAMICS G110 inverters can be operated using the following modes: Terminal This mode provides a simple method of controlling the inverter using switches and a potentiometer and is only available on the Analog varia...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 43 For a complete description of the buttons on the BOP and the procedure for attaching the BOP to the inverter, see Appendices C and D starting on page 82. For more information on using the BOP, please refer to Section 3....
Commissioning 04/2005 SINAMICS G110 Operating Instructions 44 6SL3298-0AA11-0BP0 3.4.2 Commissioning Overview Depending on the variant and desired mode (see Table 3-3 on page 41), different possibilities are available for the advanced commissioning. Table 3-4 below gives an overview on how to: ¾ Cha...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 45 3.4.3 Changing the Motor Base Frequency The default motor base frequency of the SINAMICS G110 inverter is 50 Hz. In some parts of the world motors are designed for a base frequency of 60 Hz. Changing the inverter motor ...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 46 6SL3298-0AA11-0BP0 3.4.4 Quick Commissioning (P0010=1) Quick commissioning is an easy way to optimally configure the SINAMICS G110 inverter to a specific motor. The motor data, taken from the motor rating label, is entered into the invert...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 47 NOTES ¾ P0308 & P0309 are only visible if P0003 = 3. For detailed information, please see the Parameter List. ¾ P0307 indicates kW or HP depending upon the setting of P0100. For detailed information, please see the ...
04/2005 Commissioning SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 49 3.4.5 Reset to Factory default To reset all parameters to the factory default settings; the following parameters should be set as follows: 1. Set P0010=30. 2. Set P0970=1. NOTE The reset process can take up to 3 minutes...
Commissioning 04/2005 SINAMICS G110 Operating Instructions 52 6SL3298-0AA11-0BP0 ¾ Once the cloning procedure has started, it cannot be interrupted. ¾ It is possible to copy data from inverters of different power and voltage ratings. ¾ During download, if the data is not compatible with the inverter...
04/2005 Using the SINAMICS G110 SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 53 4 Using the SINAMICS G110 WARNINGS ¾ When operating electrical devices, it is impossible to avoid applying hazardous voltages to certain parts of the equipment. ¾ Emergency Stop facilities according to EN 6020...
Using the SINAMICS G110 04/2005 SINAMICS G110 Operating Instructions 54 6SL3298-0AA11-0BP0 4.2 Command Sources (P0700) This parameter determines from which source the inverter receives the Start, Stop and Reverse commands. The SINAMICS G110 has two default settings depending on the inverter variant,...
04/2005 Using the SINAMICS G110 SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 55 Reversing the motor Analog Variant ¾ Default value: 2 – Terminal 4 (DIN 1, high) ¾ Other settings: see P0701 to P0704 in the Parameter List USS Variant ¾ Default value: 5 – Terminals 8 & 9 (RS485); control...
Using the SINAMICS G110 04/2005 SINAMICS G110 Operating Instructions 60 6SL3298-0AA11-0BP0 4.3.4 3-wire Control (P0727=3) Overview There are three signals associated with this function: 1. OFF1/HOLD – Being maintained closed the opening of the contact will switch the drive OFF and cause a ramp down ...
04/2005 Using the SINAMICS G110 SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 61 4.4 OFF and Braking Functions 4.4.1 OFF1 This command (produced by canceling the ON command) causes the inverter to come to a standstill at the selected ramp-down rate. Parameter to change ramp-down time see P...
Using the SINAMICS G110 04/2005 SINAMICS G110 Operating Instructions 62 6SL3298-0AA11-0BP0 NOTE If no digital input is set to DC braking and P1233 ≠ 0, DC braking will be active after every OFF1/OFF3 command with the time set in P1233, when the inverter output frequency (f out) has fallen below the ...
04/2005 System Parameters SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 63 5 System Parameters 5.1 Introduction to SINAMICS G110 System Parameters The parameters can only be changed by using the optional Basic Operator Panel (BOP) or the Serial Interface. Parameters can be changed and set ...
System Parameters 04/2005 SINAMICS G110 Operating Instructions 64 6SL3298-0AA11-0BP0 5.2 Parameter Overview Figure 5-1 Parameter Overview For a comprehensive description of all the parameters, please consult the SINAMICS G110 Parameter List.
04/2005 Troubleshooting SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 65 6 Troubleshooting WARNINGS ¾ Repairs on equipment may only be carried out by Siemens Service , by repair centers authorized by Siemens or by authorized personnel who are thoroughly acquainted with all the warnings and...
Troubleshooting 04/2005 SINAMICS G110 Operating Instructions 66 6SL3298-0AA11-0BP0 Checking for an ON Command If, for example, DIN0 on terminal 3 was set-up to give an ON command, the following procedure would allow the user to check that an ON command is present: 1. Ensure the BOP is connected to t...
04/2005 SINAMICS G110 Specifications SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 67 7 SINAMICS G110 Specifications Table 7-1 SINAMICS G110 Performance Ratings Feature Specification Mains operating voltage and power ranges 200 V to 240 V (±10%) 1AC 120 W to 3.0 kW Input frequency 47 to 63...
04/2005 Options SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 71 8 Options The following accessories are available as options for your SINAMICS G110 Inverter. For more details please refer to the catalogue or contact your local Siemens sales office if you require assistance. Variant Depend...
Electro-Magnetic Compatibility (EMC) 04/2005 SINAMICS G110 Operating Instructions 74 6SL3298-0AA11-0BP0 9.1.3 EMC Directive Compliance with Harmonics Regulations From 1st January 2001 all electrical apparatus covered by the EMC Directive will have to comply with EN 61000-3-2 "Limits for harmonic...
04/2005 Electro-Magnetic Compatibility (EMC) SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 75 9.1.4 Three general cases of EMC performance are applicable as detailed below Case 1: General Industrial Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3 for use in Seco...
Electro-Magnetic Compatibility (EMC) 04/2005 SINAMICS G110 Operating Instructions 76 6SL3298-0AA11-0BP0 Case 3: Filtered - for residential, commercial and light industry This level of performance will allow the manufacturer / assembler to self-certify compliance of their apparatus with the EMC direc...
04/2005 Electro-Magnetic Compatibility (EMC) SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 77 Table 9-5 Compliance Table Model Remarks Case 1 – General Industrial 6SL3211-0****-*U*0 Unfiltered units, all voltages and powers. The product standard EN 61800-3 + A11 for “Adjustable speed elect...
04/2005 Removal of ‘Y’ Capacitor Link SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 79 A Removal of ‘Y’ Capacitor Link To use the SINAMICS G110 FSB and FSC on ungrounded supplies the ‘Y’ capacitor (cap) link must be removed as follows: 1. Ensure the inverter has been disconnected from all ...
DIN Rail Mounting Kit 04/2005 SINAMICS G110 Operating Instructions 80 6SL3298-0AA11-0BP0 B DIN Rail Mounting Kit The DIN Rail Mounting Kit is an optional accessory for the SINAMICS G110 inverter. It must be ordered as a separate item using the following Order Numbers: ¾ For FSA: 6SL3261-1BA00-0AA0. ...
04/2005 DIN Rail Mounting Kit SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 81 4. Holding the front of the inverter, pull the inverter forward and upwards to release it from the DIN rail. Figure B-1 Installing the DIN Rail Mounting Kit (FSA)
Fitting the Basic Operator Panel 04/2005 SINAMICS G110 Operating Instructions 82 6SL3298-0AA11-0BP0 C Fitting the Basic Operator Panel
04/2005 Description of the BOP SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 83 D Description of the BOP Panel/Button Function Effects Indicates Status The LCD displays the settings currently used by the converter. Start motor Pressing the button starts the inverter. This button is disable...
Applicable Standards 04/2005 SINAMICS G110 Operating Instructions 84 6SL3298-0AA11-0BP0 E Applicable Standards European Low Voltage Directive The SINAMICS G110 product range complies with the requirements of the Low Voltage Directive 73/23/EC as amended by Directive 98/68/EC. The units are certified...
04/2005 List of Abbreviations SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 85 F List of Abbreviations AC Alternating current AD Analog digital converter ADC1 Analog input 1 BOP Basic operator panel CP Cold Plate Assembly CPM Controlled Power Module CT Constant torque DC Direct current DIN...
04/2005 Index SINAMICS G110 Operating Instructions 6SL3298-0AA11-0BP0 87 Index 2 2-wire control · 55 2-wire Logic · 58 3 3-wire control · 55 3-wire Control · 59, 60 A Abbreviations · 85 Access Levels · 63 Advanced commissioning · 33 Advanced Commissioning · 40 Altitude · 18 Ambient operating conditi...
Suggestions and/or Corrections Suggestions Corrections To: Siemens AG Automation & Drives Group SD PM 4 P.O. Box 3269 D-91050 Erlangen Federal Republic of Germany For Publication/Manual: SINAMICS G110 Operating Instructions Email: [email protected] User Documentation From Name: Company/Service D...
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual