Page 2 - LCP3000EZ Lighting Control System; Table of Contents; Instabus
LCP3000EZ Lighting Control System Table of Contents Instabus EIB Technology 2 System Overview 3 Selection Process 4 – 10 E-Z-Config Tool 11 System Components 12 Enclosures Internally Mounted Devices 13 – 20 Load Switch N 512 13 Switch Inputs N 261 14 Annual Scheduler REG 372 15 Annual Scheduler REG ...
Page 3 - Overview —
About This Guide This Selection and Application Guide helps you select thecorrect number of LCP3000EZ panels, inputs, outputs andaccessories to fit your lighting control application. Organization System Overview Provides an introduction into the lighting control system based on Instabus EIB. Technic...
Page 4 - System Overview
System Overview The LCP3000EZ Lighting Control System is fully modular indesign. In its basic form, it consists of ten network able lowvoltage relay control panels. Each panel contains microprocessor controlled inputs and control relay modules, each containing an individual microprocessor. Each pane...
Page 5 - Selection Process
Part 1: Plan the ProjectSelecting LCP3000EZ Panels and Accessories This section describes the application selection process forthe Siemens LCP3000EZ Lighting Control System.Application selection is a two-part process in which you:1. Plan the project.2. Design the project. Each part of the process in...
Page 6 - Information Form Sample 1 — Relay Outputs
LCP3000EZ Lighting Control System Selection Process RELAY OUTPUTS LCP3000EZ A Relay Panelboard Ckt Relay Description Control Logic Manual Override Module Relay 1 A 2 B 3 C 4 D 5 E 6 F 7 G 8 H 9 A 10 B 11 C 12 D 13 E 14 F 15 G 16 H 17 A 18 B 19 C 20 D 21 E 22 F 23 G 24 H 001 002 003 Information Form ...
Page 8 - Information Form Sample 2 — Time Clock Schedules (Weekly)
LCP3000EZ Lighting Control System Selection Process Information Form Sample 2 — Time Clock Schedules (Weekly) Time Clock Schedules (Weekly Schedule) Schedule Monday Tuesday Wednesday Thursday Friday Saturday Sunday Number Description On/ Time On/ Time On/ Time On/ Time On/ Time On/ Time On/ Time Off...
Page 10 - Part 3: Determine Catalog Numbers
LCP3000EZ Lighting Control System Selection Process 5WG1 70 –8X –Z Enclosure Height Panel Designation Number of Input Modules Number of Output Modules Enclosure Options Enclosure Height 3 = 24” (up to 16 relays = 2 output (relay) modules)4 = 32” (up to 32 relays = 4 output (relay) modules)5 = 40” (u...
Page 13 - System Components
12 Enclosures The Siemens Instabus lighting control panel supports the system components and other panel mounted devices.All panel mounted devices snap into DIN rails. An integraldata rail provides 24V DC power and communications tothe system. The lighting control panel enclosures are 20 inches inwi...
Page 14 - Internally Mounted Devices; Technical Data
Load Switch N 512 The load switch N 512 is an N-systemDIN rail mounted device. Via its eightoutputs, it can switch eight separategroups of electric devices. The powersupply of the load switch N 512 isprovided by the bus (i.e., it requiresno additional power supply). The outputs may be operated manua...
Page 16 - Annual Scheduler REG 372
Annual Scheduler REG 372 The 4-channel time switch REG 372 is a DIN rail mounted device for mounting in distribution boards. Theconnection to system is made via a busconnector. The time switch offers: 322switching schedules. LCP3000EZ Lighting Control System Internally Mounted Devices Dimension Diag...
Page 17 - Annual Scheduler REG 373
16 Annual Scheduler REG 373 The 16-channel time switch REG 373 (annual scheduler) is a DIN rail mounted device. The connection to system is made via a bus connector. The time switch offers: 500 switching schedules. LCP3000EZ Lighting Control System Internally Mounted Devices 555WG1 373-5EY01 Technic...
Page 22 - Externally Mounted Devices
Dual Sensor AP 254 The Dual Sensor AP 254 providesambient light level and outdoor temperature values. These values can be read on a computer with theoptional Web access software, as wellas with the configuration software.This device controls load switchesbased on any of the pre-set thresholdlevels f...
Page 23 - Motion Detector UP 255
22 Motion Detector UP 255 The motion detector UP 255 is a proximity sensor which reacts tomovements of people, animals orother moving objects. If a motion is detected, it gives switching commands to the corresponding relay(s). It must be installed on the flush-mounted bus coupling unit (UP 114). It ...
Page 24 - Switch Interface UP 220
23 Switch Interface UP 220 The switch interface UP 220 is a binary input device for installation in a standard junction or wall switchbox. Four inputs are available for voltage-free switching contacts. Up to four switches may be connected to a switch interface UP 220. The connection to the switch in...
Page 25 - Touch Panel Vision UP 588
Touch Panel Vision UP 588 The touch panel vision UP 588 is amultifunctional display/control unit.The basis of the device is an LC displaywith a resolution of 320 x 240 pixelsand an integrated, resistive matrixwith 6 x 10 fields. The display hasbacklighting which is activated during operation and is ...