4 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Prior to Startup Before putting the product into operation, note the following: Caution Before installing and starting the module, read the instructions in thecorresponding documentation. For ordering data of...
This manual... 6 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Among other things, this release includes the following new functions: S Using the CP 1616 as a PROFINET IO Controller/Device The manual now includes a detailed description of how the CP 1616 c...
This manual... 7 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Symbols used in this manual This symbol appears in the margin to draw your attention to useful tips. This symbol highlights particularly relevant literature. Passages marked with this symbol ind...
Contents 8 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Contents This manual... 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents 8 . . . . . . . . . . . . . . . . . . . . . . . ...
Contents 9 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 5.5.1 Significance in SIMATIC NET 65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5.2 SNMP Traps 66 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Contents 10 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 9.5 Configuration Console 126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Example — SNMP Communication with OPC 128 . . . . . . . . . . . . . . . . . . . . . ....
Contents 11 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.10 Adapting Mismatched Configurations 189 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 PC Station Wizard 190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Contents 12 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17.6 Create New Variables 245 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.7 Adding and Monitoring Variables 245 . . . . . . . . . . . . . . . . . . . . . . ....
1 Welcome to Advanced PC Configuration 13 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 1 Welcome to Advanced PC Configuration 1.1 A New Concept for Your Benefit Advanced PC Configuration is the new tool with which you can commission a PCstation as part of ...
1 Welcome to Advanced PC Configuration 14 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 LDB Databases no Longer Required By configuring on a central station and with the option of downloading, LDBdatabases are no longer required for the DP, FMS, and S7 pro...
1 Welcome to Advanced PC Configuration 15 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 1.2 PC Stations in SIMATIC Use of PCs in Automation A “PC station” is a PC with communication modules and software componentswithin an automation solution with SIMATIC. ...
1 Welcome to Advanced PC Configuration 16 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Uniform Engineering Environment The PC station is handled just like a SIMATIC S7 controller during projectengineering with STEP 7 / NCM PC: You connect the S7 stations ...
1 Welcome to Advanced PC Configuration 17 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Index for Every Component To allow communication between the components in the PC station and to receiveproject engineering data, each component is assigned a unique ide...
1 Welcome to Advanced PC Configuration 18 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 1.3 A Brief Introduction to Tools and Utilities Once you have installed the SIMATIC NET software, you have the following toolsavailable: Basic tools: Station Configurat...
1 Welcome to Advanced PC Configuration 19 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 1.4 Guide to Installation and Commissioning Before you start commissioning, you should clarify the area of operation of yourPC station and select the required mode for y...
1 Welcome to Advanced PC Configuration 20 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Mixed operation is possible. Since you can set the mode for individual communication modules, you can alsouse the PC station in mixed operation. Mixed operation, in thi...
1 Welcome to Advanced PC Configuration 21 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 1.4.2 Commissioning for PG Operation - Overview PG operation is the default mode for programming devices (PG/PC) and HMIstations. Step How does it work? Tool 1. Installi...
1 Welcome to Advanced PC Configuration 22 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 1.4.3 Commissioning for Configured Mode - Overview When commissioning in the configured mode, three situations can bedistinguished. The situation depends on whether or ...
2 Getting Started “Configured Mode” 26 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 2 Getting Started “Configured Mode” The “configured mode” should be selected for productive communication betweenapplications in the PC station and the programmable contro...
2 Getting Started “Configured Mode” 27 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 2.1 Steps in Creating Project Engineering Data To create the project engineering data, you use the SIMATIC NCM PC or SIMATICSTEP 7 tool. Why do we need project engineering ...
2 Getting Started “Configured Mode” 28 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Follow the steps below: Steps in Project Engineering 1. Start the SIMATIC NCM PC from the Start menu. (Start " SIMATIC " SIMATIC NCM PC). As an alternative if “onl...
2 Getting Started “Configured Mode” 32 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Steps in Project Engineering 8. If the PC station is available online (local or remote), the next step is the initial configuration ofthe station. Note: To load the projec...
2 Getting Started “Configured Mode” 33 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Where to go from here - optional activities Once the project engineering configuration has been accepted, the PC station isoperational. The following steps allowing the use...
2 Getting Started “Configured Mode” 34 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 2.2 Steps for Initial Configuration For the initial configuration, use one of the following tools depending on theprocedure: S Station Configuration Editor S STEP 7 / NCM ...
2 Getting Started “Configured Mode” 37 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 2.2.2 Case b) Initial configuration with XDB file In this case, you can import the XDB file with the project engineering data for thePC station directly. The advantage of t...
2 Getting Started “Configured Mode” 38 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 How to Make the ”Initial Configuration with an XDB File” 3 If you want to prevent project engineering data from being transferred online at a later point intime, select th...
2 Getting Started “Configured Mode” 39 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 2.2.3 Initial configuration without XDB file In this case, you specify the modules during initial configuration in the StationConfiguration Editor. You can transfer project...
3 Getting Started “PG Operation” 41 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 3 Getting Started “PG Operation” This chapter shows you how you can configure your PC module in PG operation.In this situation, we distinguish two modes: S Programming device ...
3 Getting Started “PG Operation” 42 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 3.1 Configuration for PG Operation - Programming Device(PG/PC) You configure a module using the “Set PG/PC Interface“ tool. Follow the steps below: How to Configure for PG Op...
3 Getting Started “PG Operation” 43 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 How to Configure for PG Operation 3. Set the required communication parameters. With your module selected, you can click on “Properties” and then set the communicationparamete...
3 Getting Started “PG Operation” 44 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 3.2 Configuration for PG Operation - HMI Stations You configure a module using the “Set PG/PC Interface” tool. Initially the procedure is identical to configuration for PG op...
3 Getting Started “PG Operation” 47 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Entries in the Client Program For communication without project engineering data as described here, all the dataof the partner device relevant for communication must be known....
4 Using Additional Functions - Special Features to Note 49 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 4 Using Additional Functions - Special Features to Note 4.1 Checking the Configuration and Diagnostics The “Configuration Console” tool is a central too...
4 Using Additional Functions - Special Features to Note 50 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 4.2.1 Detecting Errors in Communication with the OPC Scout Introduction The OPC Scout shows you the status of the communication connections. This canbe...
4 Using Additional Functions - Special Features to Note 51 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Errors when Adding Variables S Variable cannot be added Adding some or all variables is denied in the Navigator of the OPC Scout.Possible causes for thi...
4 Using Additional Functions - Special Features to Note 52 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 4.3 Further Functions / Special Features 4.3.1 Adopting the Project Engineering and Symbols from PROFINETiMap and SIMOTION Scout You can also use the s...
4 Using Additional Functions - Special Features to Note 53 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 You can check the selected module with the “Configuration Console” programusing the “Access points” function: S fixed access point SIMOTION CP_SM_1: e.g...
4 Using Additional Functions - Special Features to Note 54 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Step Description 1 Start the “Configuration Console” program (taskbar Start " Simatic " SIMATIC NET " Configuration Console). 2 In the navi...
4 Using Additional Functions - Special Features to Note 55 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 4.3.3 Points to Note with SOFTNET Industrial Ethernet Modules Introduction Modules operated with the “SOFTNET Industrial Ethernet” software product arei...
5 Project Engineering for the OPC Server 56 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 5 Project Engineering for the OPC Server OPC Server With the SIMATIC NET OPC Server described here, SIMATIC NET offers you aconvenient tool with which your PC applica...
5 Project Engineering for the OPC Server 57 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 5.1 Significance of Project Engineering The OPC Server Application Type The OPC Server can be configured as an interface to all available communicationprotocols. You c...
5 Project Engineering for the OPC Server 60 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 5.3 Specifying Connection Properties for the OPC Server inProject Engineering When using OPC, communication connections are established and managed bythe OPC Server. ...
5 Project Engineering for the OPC Server 61 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 FMS Connection Here, you assign a VFD to the FMSconnection; you create VFDs in theproperties dialog of the OPC Server. The Options button opens the dialog in whichyou ...
5 Project Engineering for the OPC Server 64 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 5.4 Using Symbols for S7 Connections Symbol tables are created during project engineering with STEP 7 on a centralengineering station in the form of STI files. You ca...
5 Project Engineering for the OPC Server 65 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 5.5 Configuring OPC Properties for SNMP in ProjectEngineering 5.5.1 Significance in SIMATIC NET You configure the OPC server an SNMP client in the “SNMP” tab by specif...
5 Project Engineering for the OPC Server 66 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Using the “Edit Plant Configuration” button, you obtain a list with all the devicesregistered with the OPC server. You can add others to this list or edit the paramet...
6 Using the CP 1616 as a PROFINET IO Controller/Device 68 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 6 Using the CP 1616 as a PROFINET IO Controller/Device Note As of STEP 7 V5.3 SP3, the CP 1616 is part of the hardware library. If you want to operate t...
6 Using the CP 1616 as a PROFINET IO Controller/Device 71 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 6.1 Initialize CP 1616 (IP address and device name) Assigning the IP address Follow the steps outlined below 1. Open the SIMATIC Manager. 2. Select the m...
6 Using the CP 1616 as a PROFINET IO Controller/Device 72 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 6.2 Configuring the CP 1616 Using the CP 1616 as a PROFINET IO Controller Follow the steps outlined below 1. Create a new project in the SIMATIC Manager...
6 Using the CP 1616 as a PROFINET IO Controller/Device 73 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Follow the steps outlined below 10. Now configure the devices in the PROFINET IO system to meet your requirements. 11. Once configuration is completed (f...
6 Using the CP 1616 as a PROFINET IO Controller/Device 74 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Using the CP 1616 as a PROFINET IO Device To use the CP 1616 as PROFINET IO device, select (or create) a projectcontaining a PROFINET IO controller, a P...
6 Using the CP 1616 as a PROFINET IO Controller/Device 75 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Using the CP 1616 as PROFINET IO Controller and Device You can also use the CP 1616 as a controller and device at the same time. In otherwords, the same ...
6 Using the CP 1616 as a PROFINET IO Controller/Device 77 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Follow the steps outlined below 12. Disable the “Assign IP address via IO Controller” option. Based on the device name, the IP address of the CP 1616 is ...
7 Example — OPC Application for Industrial Ethernet 79 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 7 Example — OPC Application for Industrial Ethernet 7.1 Overview Explanation of the Configuration Example This example illustrates how you can connect an S7...
7 Example — OPC Application for Industrial Ethernet 80 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Initial Situation If you want to try out the example yourself, you require the following: S a PC S a communication module for Industrial Ethernet (CP 1613)...
7 Example — OPC Application for Industrial Ethernet 81 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 7.2 Hardware and Software Installation Installing the Software Activity 1. Turn on the PC and start Windows. 2. Insert the SIMATIC NET 11/2003 CD. If the in...
7 Example — OPC Application for Industrial Ethernet 82 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 7.3 Creating the STEP 7 Project 7.3.1 STEP 7 Project Engineering on a Central Engineering Station In the requirements, we have already said that you requir...
7 Example — OPC Application for Industrial Ethernet 83 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Activity In NetPro, you will find the network assignment of the SIMATIC 400 station and the PC stationdisplayed graphically. 7.3.2 Using Symbol Files Introd...
7 Example — OPC Application for Industrial Ethernet 84 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Specifying the Use of Symbol Files Activity 1. Select the “OPC server” in the “PC station” in “HW Config“ (or NetPro) and select “ObjectProperties” in the ...
7 Example — OPC Application for Industrial Ethernet 86 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 7.4 Configuring the PC Station Overview After starting the PC station, after installing the software and installing the CP1613, the CP 1613 is in PG operat...
7 Example — OPC Application for Industrial Ethernet 87 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Procedure for “Initial Configuration” 1. Start the Station Configuration Editor by selecting it in the start menu (Start " Station Configuration Editor)...
7 Example — OPC Application for Industrial Ethernet 90 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 7.5 Using the OPC Scout 7.5.1 Establishing a Connection to the Server The OPC Scout as Client for Commissioning and Testing You can now access the data obj...
7 Example — OPC Application for Industrial Ethernet 91 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 7.5.2 Inserting a Group and Variables Organizing Process Variables The process variables of the OPC server (known as OPC items) are assigned togroups. You t...
7 Example — OPC Application for Industrial Ethernet 93 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 7.5.3 Displaying and Modifying Values of Variables Executing Synchronous Write Jobs Activity 1. The selected variables are displayed with the following addi...
8 Example — OPC Application for PROFIBUS-DP 94 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 8 Example — OPC Application for PROFIBUS-DP 8.1 Overview Explanation of the Configuration Example This example illustrates how to connect an ET 200 B DP slave with...
8 Example — OPC Application for PROFIBUS-DP 100 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 8.4 Changing the configuration on the PC station Below, you will see how to expand the hardware configuration of the local PCstation by a DP master system and a D...
8 Example — OPC Application for PROFIBUS-DP 102 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 8.4.2 Inserting a DP Master System CP 5613 as DP Master In the STEP 7 project, a SIMATIC PC station was created as an image of the localPC. This PC station alread...
8 Example — OPC Application for PROFIBUS-DP 103 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 8.4.3 Inserting a DP Slave ET 200B as DP Slave In this section, you insert an ET 200B as DP slave and assign it to the DP mastersystem. Activity 1. Open the catalo...
8 Example — OPC Application for PROFIBUS-DP 106 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 8.5.2 Inserting Groups and Variables Organizing Process Variables The process variables of the OPC server (known as OPC items) are assigned togroups. You therefor...
8 Example — OPC Application for PROFIBUS-DP 107 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Activity 4. Select the following OPC items from the appropriate branches in the left-hand window andtransfer these variables to the right-hand pane by clicking on ...
9 Example — Unspecified Connection from a PC Application 109 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 9 Example — Unspecified Connection from a PC Application 9.1 Overview Explanation of the Configuration Example In this chapter you will learn how to c...
9 Example — Unspecified Connection from a PC Application 116 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 9.4 Creating, Editing and Downloading a STEP 7 Project Below, you will see how to create a new STEP 7 project with PC Station Wizard,add an S7 connec...
9 Example — Unspecified Connection from a PC Application 118 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 9.4.2 Edit the Network and Connection Project Engineering Data Activity 1. Select “Edit network and connection configuration”. Click on the “Finish” ...
9 Example — Unspecified Connection from a PC Application 124 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 9.4.3 Downloading the Project Engineering Configuration Activity 1. With “PLC " Download to Current Project " Selected Stations”, the project...
9 Example — Unspecified Connection from a PC Application 126 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 9.5 Configuration Console The “Configuration Console“ makes all local settings and diagnostic functionspossible. You also have the settings or diagno...
10 Example — SNMP Communication with OPC 128 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 10 Example — SNMP Communication with OPC Introduction This section describes how you link network components and nodes with an SNMPagent to a PC station over an OPC ...
10 Example — SNMP Communication with OPC 129 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 10.1 Hardware and Software Installation Installing the Software Activity 1. Turn on the PC and start Windows. 2 Insert the SIMATIC NET 11/2003 CD. If the installation...
10 Example — SNMP Communication with OPC 130 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 10.2 Configuration of the SNMP OPC Server Activity 1. Start “SIMATIC NCM PC Config” with Start " SIMATIC " SIMATIC NCM PC Manager and then double-click on th...
10 Example — SNMP Communication with OPC 132 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 10.2.1 Editing the Plant Configuration Activity 1. In this case, no devices have been registered yet. Click on the “Add ...” button to make a new node known in the p...
10 Example — SNMP Communication with OPC 139 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 10.4.2 Inserting a Group Organizing Process Variables The process variables of the OPC server (known as OPC items) are assigned togroups. You therefore require an OPC...
10 Example — SNMP Communication with OPC 141 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 10.4.3 Setting the Trap Recipient based on the Example of anOSM/ESM Writing Values You set the trap recipient of an OSM/ESM by assigning suitable values to two OPCite...
10 Example — SNMP Communication with OPC 143 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 10.5 Creating a Device Profile with the MIB Compiler Device Profile A device profile contains the SNMP objects (OPC items) required for the SNMPinterface of the OPC S...
11 Example — PROFINET Communication with OPC 147 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 11 Example — PROFINET Communication with OPC Introduction This example illustrates how to link an S7-300 programmable controller with a PCstation over a PROFINET ...
12 Station Configuration Editor Tool 153 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 12 Station Configuration Editor Tool With the Station Configuration Editor, you can access the component managementof the Station Manager in the PC station. You require t...
12 Station Configuration Editor Tool 154 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Area of Application / Use Cases S Initial configuration (commissioning) When a module is started up for the first time, it must be configured. This initialconfiguration ...
12 Station Configuration Editor Tool 156 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Creating new components You can select the components installed on your PC station (applications, OPCServer, modules such as controllers) by clicking the “Add” button. T...
12 Station Configuration Editor Tool 157 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 You can import an XDB file at any time regardless of the current mode (onlineor offline). You can also specify (option) whether you want the “offline mode” tobe set follo...
12 Station Configuration Editor Tool 158 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Checks and diagnostics S Note on diagnostic entries The entry in the “Status” field in the configuration list constantly informs youwhether or not the created component ...
12 Station Configuration Editor Tool 159 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Configuring Activation of Warnings When warnings are enabled, a new event in the diagnostic buffer causes a displayin the station manager ICON in the system tray. Whether...
13 SIMATIC NCM PC Project Engineering Tool 160 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 13 SIMATIC NCM PC Project Engineering Tool SIMATIC NCM PC is the central tool for configuring the communications servicesfor your PC station. After creating your c...
13 SIMATIC NCM PC Project Engineering Tool 161 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Functions To create the configuration and project engineering data of a PC station, use thefollowing functions: S Creating and configuring components of the PC stat...
13 SIMATIC NCM PC Project Engineering Tool 162 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Notice Optional packages are not supported by SIMATIC NCM PC. If you are editing aproject that was created or edited in STEP 7, it may contain components fromSTEP ...
13 SIMATIC NCM PC Project Engineering Tool 163 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.2 Relationship Between SIMATIC NCM PC and STEP 7 SIMATIC NCM PC and STEP 7 are compatible with each other. S You can open and edit projects that you created with...
13 SIMATIC NCM PC Project Engineering Tool 164 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 The following graphic illustrates the differences once more: S SIMATIC PC station S Other station S SIMATIC S5 S PG/PC S SIMATIC PC station S Other station S SIMAT...
13 SIMATIC NCM PC Project Engineering Tool 165 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.3 Creating a PC Station The PC Station in the STEP 7 Project The “SIMATIC PC Station” is an object in a SIMATIC STEP 7 project. A typical PCstation for OPC opera...
13 SIMATIC NCM PC Project Engineering Tool 166 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Creating and Managing Objects After starting SIMATIC NCM PC, you either open an existing project or create anew one. You use projects to manage your configurations...
13 SIMATIC NCM PC Project Engineering Tool 167 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Note When you start STEP 7, a wizard is opened that helps you to create a newproject. In SIMATIC NCM PC, this wizard is replaced by the PC Station Wizard.Depending ...
13 SIMATIC NCM PC Project Engineering Tool 168 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 13.4 Configuring a PC Station with SIMATIC NCM PC Config Creating an Image of the PC Configuration To allow the configuration data sent by the configuration system...
13 SIMATIC NCM PC Project Engineering Tool 170 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 PC Components in the Catalog For the SIMATIC PC station, you can select the following components: S Application - Application (standard application) You use standa...
13 SIMATIC NCM PC Project Engineering Tool 171 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.5 Creating the DP Master System Read the information below if you want to use a PROFIBUS CP and configure aDP master system. Significance of the Configuration Da...
13 SIMATIC NCM PC Project Engineering Tool 173 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.6 Creating a PROFINET IO System The following information applies if you want to use an Ethernet CP asPROFINET IO controller in the PC station and want to config...
13 SIMATIC NCM PC Project Engineering Tool 174 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Follow the steps below: 4 Now go to the catalog and insert the IO devices that will be addressed over the application. Drag the IO device from the catalog onto the...
13 SIMATIC NCM PC Project Engineering Tool 175 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.7 Configuring Connections Meaning During operation, configured connections are established either implicitly or onrequest, depending on the parameter assignment....
13 SIMATIC NCM PC Project Engineering Tool 176 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Connections to S7 Stations When you configure systems that include PC stations and SIMATIC S7stations, the use of STEP 7 is generally advisable. You can then edit ...
13 SIMATIC NCM PC Project Engineering Tool 177 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.8 Project Engineering for a PC Station as DP Slave This section explains how to create the project engineering for a PC station withthe CP 5611 as DP slave. Two ...
13 SIMATIC NCM PC Project Engineering Tool 178 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Follow the steps outlined below: 6. Save and compile the configuration. In the next section, the PC station will be assigned to a DP master system, in theexample a...
13 SIMATIC NCM PC Project Engineering Tool 182 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Follow the steps outlined below: 3. Repeat these steps for all submodules. 4. Save and compile the configuration. 13.8.2 Configuration with a “Third - party” DP Ma...
13 SIMATIC NCM PC Project Engineering Tool 184 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 13.9 Downloading Project Engineering Data to the PC Station(after Initial Configuration) To allow applications to exchange information over configured communicatio...
13 SIMATIC NCM PC Project Engineering Tool 185 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.9.1 Online Mode The online mode allows you to download the configuration data directly to a PCstation attached to the network (MPI, PROFIBUS or Ethernet), or to ...
13 SIMATIC NCM PC Project Engineering Tool 187 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Using the PC Station Wizard. In the situation described here, “online - local”, the use of the PC Station Wizard isalso possible. If you have not yet created the pr...
13 SIMATIC NCM PC Project Engineering Tool 188 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Note To make it possible to identify the PC station, the station name in the configurationmust match the locally configured station name. If this is not the case, ...
13 SIMATIC NCM PC Project Engineering Tool 189 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 13.10 Adapting Mismatched Configurations The Station Configuration Editor displays assigned indexes If you cannot download configuration information to the PC stati...
14 PC Station Wizard 190 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 14 PC Station Wizard The PC Station Wizard supports you when creating projects in SIMATIC NCM PCor STEP 7. It allows the automatic adoption of configuration on the local PCstation. This...
14 PC Station Wizard 191 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 The PC Station Wizard supports you in the following situations: S Changing local settings If the SIMATIC NCM PC configuration tool is installed on the destination PCstation, the wizard c...
15 Symbol File Configurator Too 192 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 15 Symbol File Configurator Too With the Symbol File Configurator, you can create symbol files that allow you theoption of access to symbolic variables over the SIMATIC NET O...
15 Symbol File Configurator Too 193 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 How to Start the Symbol File Configurator You start the Symbol File Configurator from the Windows Start menu: Start " SIMATIC " SIMATIC NET " Settings " Symbol...
15 Symbol File Configurator Too 194 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Parameter Meaning EU Lo Indicates the low limit of the range of values of the variable(Engineering Units Low). The information about a range ofvalues is used for the “Percent...
15 Symbol File Configurator Too 195 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 15.2 The Meaning of Symbols Definitions The terms listed below are important in conjunction with the Symbol FileConfigurator: Term Meaning OPC ItemID The OPC ItemID is the ide...
15 Symbol File Configurator Too 196 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 When to Use Symbols? The use of symbolic names is not mandatory. One exception to this iscommunication over PROFInet or communication with a SIMOTION partner. Hereonly symbol...
15 Symbol File Configurator Too 197 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 15.3 Menus of the Symbol File Configurator in Detail “File” Menu This menu contains standardized commands for working with the files (forexample, “Open File”, “Save File” etc....
15 Symbol File Configurator Too 198 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 “Edit” Menu This menu contains commands with which you can edit folders and symbols. Here,you will find the essential functions of the tool. In the following sections, you wi...
15 Symbol File Configurator Too 199 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 15.4 Managing Symbols 15.4.1 How to Insert a New Symbol Activity 1. Select a folder in the left-hand area of the program window. The program always creates newsymbols below th...
15 Symbol File Configurator Too 200 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Activity 4. The variable appears in the Selected Items part of the window. Add a symbolic name here. Repeat steps 3 and 4 when necessary for other variables. 5. Close the “Ad...
15 Symbol File Configurator Too 201 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 15.4.3 How to Add a Name Space Prefix Activity 1. Select “Add/Change Prefix ” in the “Edit” menu. The “Change Prefix” dialog appears. 2. Here, enter a name for the prefix or c...
15 Symbol File Configurator Too 202 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 15.4.6 How to Export a Symbol File Activity 1. In the OPC Address Space dialog, select the context-sensitive menu “Export to CSV File”. Adialog appears in which you can save ...
16 Configuration Console Tool 203 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16 Configuration Console Tool The Configuration Console is a snap-in program embedded in the MicrosoftManagement Console (MMC) and provides a wide range of options for configuri...
16 Configuration Console Tool 204 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Structure In the Configuration Console, you navigate in basically the same way as in theWindows Explorer. You navigate on the left-hand side. On the right-hand side, the input/...
16 Configuration Console Tool 205 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2 Support During Commissioning and Operation Overview The essential functions provided by the “Configuration Console” tool forcommissioning and operation are as follows: S Co...
16 Configuration Console Tool 207 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Activity 2 Click the “Restart” button. If currently possible, the module is reset. The result of the restart is displayed in the text box. 16.2.2 Forcing the OPC Server to Close...
16 Configuration Console Tool 209 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2.3 Activating Configured Protocols Step by Step By configuring a DP master system and connections, you specify which protocolswill be used by the OPC Server. During the comm...
16 Configuration Console Tool 211 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2.4 Setting a Symbol File for OPC Note The following information relates to the “Configuration Console” program of theSIMATIC NET software as of Version 6.1. If you want to u...
16 Configuration Console Tool 213 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2.5 Setting Traces A trace logs the internal sequences of the component. It allows you to check thefunctions, for example of a user program. Depending on the configuration, t...
16 Configuration Console Tool 217 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2.6 Language Setting As of the SIMATIC NET CD 2005 (V6.3), it is now possible to change the languageof the program user interface after installation. To adopt the modified la...
16 Configuration Console Tool 218 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.2.7 Automatic Startup of Applications and Services; Applications and services you set up on a PC station can be synchronized with thestartup of the PC station. As soon as th...
16 Configuration Console Tool 220 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Note for software developers: Applications can be synchronized with the startup and shutdown using globalevents. S Event ”SimaticNetPcStationUpEvent”: The global event ”Simatic...
16 Configuration Console Tool 223 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.2.9 Configuration Examples You can display examples of how specific use cases can be configured directlyover the user interface. Follow the steps below to display the configu...
16 Configuration Console Tool 224 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.3 Editing the Configuration Overview During configuration you can do the following: S Change the mode of the module and set the index S Set the Industrial Ethernet network p...
16 Configuration Console Tool 226 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.3.2 Displaying and Setting the Industrial Ethernet NetworkParameters for a CP 1613 For the Industrial Ethernet module CP 1613, the current settings are displayed andcan be m...
16 Configuration Console Tool 228 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.3.3 Setting the Industrial Ethernet Station Addresses Note The modules for SOFTNET Industrial Ethernet are managed by the Windowsoperating system. This means that the statio...
16 Configuration Console Tool 229 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Activity 2 Depending on the mode set for the module, you can modify or only check the addressparameters. S Configured mode The parameters are set in the project engineering and ...
16 Configuration Console Tool 231 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.3.5 Setting the PROFIBUS DP Slave To be able to use the DP slave submodule of the CP 5614/CP 5614 FO/CP 5614A2 with OPC, configure the submodule as described below. It is not...
16 Configuration Console Tool 233 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.4 Diagnostics with “Configuration Console” Overview In diagnostics with “Configuration Console”, you can, for example, do the following S Display the operability of the modul...
16 Configuration Console Tool 236 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.4.3 Displaying PROFIBUS Network Nodes If the module is operational, a list with all the nodes on the bus is created afterstarting this function. If the module is currently c...
16 Configuration Console Tool 238 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 16.4.4 Displaying PROFIBUS Network Parameters Follow the steps outlined below... Activity 1 Open the “Modules” folder in the navigation area. Select the relevant PROFIBUS modul...
16 Configuration Console Tool 239 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 16.4.5 Displaying Version Information of Hardware and Firmware Follow the steps outlined below... Activity 1 Open the “Modules” folder in the navigation area. Select the relevan...
17 OPC Scout 240 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17 OPC Scout With the OPC Scout, you can test an OPC application or commission the OPCserver. The following description assumes that you are familiar with the terminology andmechanisms of OPC (...
17 OPC Scout 241 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 How to Start the OPC Scout You start the OPC Scout from the Start menu of the Windows operating system: Programs " SIMATIC NET " PROFIBUS " CP5613_5614 " OPC Scout (or in the par...
17 OPC Scout 242 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17.2 Connecting the OPC Scout to a Local Server Before you can work with the OPC Scout, you must connect the OPC Scout with aserver. Activity 1. In the Server and Groups Navigator open the Serv...
17 OPC Scout 243 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 17.4 Create a Group You must first create one or more groups in which you can then manage the itemsyou want to monitor or control. Activity 1. Open the Group menu and select the Add Group menu c...
17 OPC Scout 244 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Activity 1. Select the required group for which you want to browse the process space of the server in theServers and Groups Navigator of the OPC Scout. 2. Open the Item menu and select the Add ...
17 OPC Scout 245 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 17.6 Create New Variables You can create new variables using the OPC Navigator window. Activity 1. In the left column of the OPC Navigator window, select the entry for which you want to create a...
17 OPC Scout 246 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17.8 Customizing the Display You can decide what information is displayed for variables in the OPC Scoutwindow. Activity 1. Open the View menu and click the Options menu command. The ”Options” ...
17 OPC Scout 247 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Meaning of the Columns Name Meaning OPC ItemIDs Unique name of the OPC item. Value Value of the variable displayed in the format set in the Format column. Format Representation For integers, you...
17 OPC Scout 248 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17.10 Change Values Using the OPC Scout you can modify the values of writable variables directly. Activity 1. Select the variable whose value you want to change in the variable display in the m...
17 OPC Scout 249 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 The menu command has the following function Print Item List to File Writes the currently displayed items and all values to afile. A file list box is displayed in which you can enter the filename...
17 OPC Scout 250 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 17.11.4 Group Menu The Group menu contains the following commands: The menu command has the following function Add Group Adds a group. The Add Group window opens. You enter the name andproperti...
17 OPC Scout 251 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 17.11.6 ? Menu The ? menu contains the following commands: The menu command has the following function Change Language Changes the display language of the OPC Scout. About OPC Server Opens a dia...
18 DCOM Settings with the dcomcnfg System Program 252 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 18 DCOM Settings with the dcomcnfg System Program 18.1 Characteristics, Functions and Activation To allow a client to use a COM object on another computer, ...
18 DCOM Settings with the dcomcnfg System Program 255 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Note In Windows XP + SP2, the “Default COM Security” tab has been renamed to”COM Security”. Note If you lower the security settings, the system must be resta...
18 DCOM Settings with the dcomcnfg System Program 256 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Settings When operating in a domain, the default authentication level can by set to“Connect” and the Default Impersonation Level to “Identify” for security ...
18 DCOM Settings with the dcomcnfg System Program 258 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Table 18-1 Default Permissions Meaning Access permissions The default access permissions for all COM objects specify whichaccounts are allowed to access the...
18 DCOM Settings with the dcomcnfg System Program 260 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 18.4 DCOM Configuration / “Applications” Tab Description of the Settings In Windows XP, first open the “DCOM Configuration” folder in “My Computer” todispla...
18 DCOM Settings with the dcomcnfg System Program 261 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 18.5 “Default Protocols” Tab Description of the Settings In the “Default Protocols” tab, you specify the network protocols that are availablefor DCOM. Note T...
18 DCOM Settings with the dcomcnfg System Program 262 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 18.6 Configuration of the Server Computer Introduction On the PC station in which the OPC server is operated, you must set whichaccounts have the right to u...
18 DCOM Settings with the dcomcnfg System Program 263 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 18.6.1 “General” Tab: Registering the OPC Server With the OPC server, the default setting assumes an open system and assumesthat the user will adapt the sett...
18 DCOM Settings with the dcomcnfg System Program 264 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 18.6.2 “Location” Tab Description of the Settings The “Location” tab is used to specify the computer on which the server is started.Since the configuration ...
18 DCOM Settings with the dcomcnfg System Program 265 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 18.6.3 “Identity” Tab Description of the Settings The settings made in the “Identity” tab specify the account to be accessed to checkthe permissions of the u...
18 DCOM Settings with the dcomcnfg System Program 267 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 18.6.4 “Security” Tab Introduction You specify the access permissions for the OPC server in the “Security” tab. For the three aspects relevant to COM objects...
18 DCOM Settings with the dcomcnfg System Program 268 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Specifying the Standard Permissions The users that are allowed to use the OPC server must be entered in the defaultaccess permissions, launch permissions, a...
18 DCOM Settings with the dcomcnfg System Program 269 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 New as of Windows XP + SP2: As of Service Pack 2 for Windows XP, communication over OPC also requires thefollowing permissions to be set up: S Local and remo...
18 DCOM Settings with the dcomcnfg System Program 270 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Specifying Access Permissions Activity 1. After clicking the “Edit” button in the “Use custom access permissions” box, the following dialogbox appears: 2. A...
18 DCOM Settings with the dcomcnfg System Program 271 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Specifying Launch Permissions Activity 1. After clicking the “Edit” button in the “Use custom launch permissions” box, the following dialogbox appears: 2. Ad...
18 DCOM Settings with the dcomcnfg System Program 272 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Specifying Configuration Permissions Activity 1. After clicking the “Edit” button in the “Use custom configuration permissions” box, the followingdialog box...
18 DCOM Settings with the dcomcnfg System Program 273 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 18.7 Configuration of the Client Computer Overview When operating with DCOM, this situation is that the OPC server runs on adifferent computer from the OPC c...
18 DCOM Settings with the dcomcnfg System Program 274 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 Registering the OPC server - follow the steps below: The location of the server must be specified in the “Location” tab. For DCOMoperation, only the check b...
18 DCOM Settings with the dcomcnfg System Program 275 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Registering the OPC Scout as Client The OPC Scout is an OPC client that you will find in DCOM as a registered object.If you display the properties of the OPC...
18 DCOM Settings with the dcomcnfg System Program 276 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 It is advisable to register other OPC clients as DCOM objects. The advantage ofthis is that you can configure the security settings as described here withDC...
A Notes for Users of Older Versions 277 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 A Notes for Users of Older Versions The following sections include detailed information on the differences between thenew and previous PC products from SIMATIC NET A.1 LDB...
A Notes for Users of Older Versions 278 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 A.2 Project Engineering up to SIMATIC NET CD 05/2000 Description A project engineering configuration created with the tools of the SIMATIC NETproduct CDs up to and includ...
A Notes for Users of Older Versions 279 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 Previous Project Engineering with LDB and XDB Databases Even when the entire communication of all modules for the S7 protocol was storedin the XDB database, separate LDB d...
A Notes for Users of Older Versions 280 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 A.3 Continued Use of Previous Project Engineering Continued Use of Databases and Project Engineering Tools The following table shows an overview of the previous database ...
A Notes for Users of Older Versions 281 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 A.4 Industrial Ethernet - Effects on Older Product Versions(SIMATIC NET CD 05/2000 and earlier) Introduction This section describes what changes are necessary in Industria...
A Notes for Users of Older Versions 282 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 TF-1613 up to version 2.1 for Windows 2000 Pro or Windows NT 4.0 Situation: Application associations will continue to be configured as previously with theCOML TF program....
A Notes for Users of Older Versions 286 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 SOFTNET-S7 up to version 5.3 for Windows 2000 Pro, Windows NT 4.0 orWindows 98 Situation: Windows 98 is no longer supported. An S7 project engineering configuration creat...
B Description of the PROFINET Configuration File 287 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000 - G8976 - C156 - 07 B Description of the PROFINET Configuration File Configuration File When you install the PROFInet OPC Server for SIMATIC NET, a configuration fileis instal...
B Description of the PROFINET Configuration File 288 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000 - G8976 - C156 - 07 The Cycle Time Parameter This parameter will be configured in the user interface as of SIMATIC NET V6.1with STEP 7/SIMATIC NCM PC V5.2 and higher. Paramet...
B Description of the PROFINET Configuration File 289 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000 - G8976 - C156 - 07 The AbortConnectionAfter Parameter This parameter is specified in section [<connectionname>]. The connection name contains the IP address from the iM...
B Description of the PROFINET Configuration File 290 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000 - G8976 - C156 - 07 The InitiateTimeout Parameter This parameter is specified in section [<connectionname>]. The connection name contains the IP address from the iMap p...
B Description of the PROFINET Configuration File 291 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000 - G8976 - C156 - 07 The Timeout Parameter This parameter is specified in section [<connectionname>]. The connection name contains the IP address from the iMap project en...
C References and Literature 292 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 C References and Literature SIMATIC NET, manualIndustrial Communication with PG/PCPart of - the manual package Industrial Communication with PG/PC- the SIMATIC NET CD Siemens AG ...
C References and Literature 294 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 On using PROFINET IO and PROFINET CBA : PROFINET System Description System Manual Siemens AG On configuring and programming PROFINET IO: From PROFIBUS DP to PROFINET IOProgrammin...
D Glossary 295 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 D Glossary Access point The access point is a symbolic name with which the user program can accessthe assigned communication interface / module. Advanced PC Configuration (APC) As of the SIMATIC N...
D Glossary 296 Commissioning PC Stations - Manual and Quick Start Release 5/2005 C79000- G8976- C156- 07 PC Station In this context, a PC station means a PC with communications modules andapplications. The role of this PC might be, for example, to communicate withSIMATIC S7 devices and perform proce...
297 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 E Document History This chapter provides you with an overview of the previous releases of this manualand the functional additions. New in release 01 / 2005 (C79000 - G8976 - C156 - 06) Among other things, th...
299 Commissioning PC Stations - Manual and Quick StartRelease 5/2005 C79000- G8976- C156- 07 N NCM PC and STEP 7, 163NetPro, 160 O Offline mode, 157, 187Online mode, 157, 185OPC Navigator, 243OPC Scout, 18, 49, 240OPC Server, 279 connection properties, 60properties, 58 OPC server, 15 errors when con...
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual