Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 2 of 18 1 Scope The product information for the system software M02.01/M01.07 remains valid. The following information represents a supplement. The delivery consists...
Page 3 - Supplementary Documentation
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 3 of 18 1.1 Supplementary Documentation In addition to the tools required for startup of your AS 488/TM, the commissioning diskette contains a document file for the ...
Page 4 - Master Type File for COM ET200 / COM PROFIBUS
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 4 of 18 1.2 AS System File for PROGRAF AS+ Your commisioning diskette contains a directory PROGRAF after extracting. This contains the system file AS.SYS required fo...
Page 5 - Commissioning; The file RM3_PC1.SYS on the memory card must; never; be deleted or
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 5 of 18 2 Commissioning The Memory Card contains the entire system software for AS 488/TM. It responds with the version ID M02.02 . To perform an upgrade or update f...
Page 6 - Startup by Commissioning Terminal; batch
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 6 of 18 2.1 Startup by Commissioning Terminal The extracted IBS tool diskette contains your local tool in the directory ASBEDIEN. Install this on your PC to be used ...
Page 7 - Procedure for Upgrade to M02.02 with Programming Device PG740; copies all files from memory card into the upgrade directory.
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 7 of 18 2.2 Procedure for Upgrade to M02.02 with Programming Device PG740 Stop your AS running (e.g. with STO) and then switch the AS off before pulling the memory c...
Page 10 - Update by Programming Device PG740; name
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 10 of 18 To check the update procedure, start the new ASBEDIEN and select the AS status screen ( BT,STAT:@; ). In addition to the start-up message, the system versio...
Page 11 - Installation of the Reloadable DP Driver Blocks
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 11 of 18 2.4 Installation of the Reloadable DP Driver Blocks (DPAE, DPAA, DPBE, DPBA) In addition to the execution system and the standard blocks of the AS 488/TM, y...
Page 12 - Installation of the Reloadable IP262 Driver Blocks
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 12 of 18 2.5 Installation of the Reloadable IP262 Driver Blocks (RIP, KRIP) In addition to the execution system and the standard blocks of the AS 488/TM, your memory...
Page 13 - Removed; concerned
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 13 of 18 3 Removed Errors F: Function concerned A: Appearance M: Modification • F: ASBEDIEN: command LANW A: The transmission doesn't work. Afterwards also the other...
Page 14 - Extended; ASBEDIEN under Windows NT
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 14 of 18 4 Extended Functions 4.1 General Extensions F: Function concerned A: Appearance E: Extension • F: Central configuration via bus A: If the disconnection is n...
Page 15 - Online Configuring as Stand-alone Operating Terminal; colored picture transmission
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 15 of 18 4.3 Online Configuring as Stand-alone Operating Terminal As replacement for an AS 230/235 local operating console with screen, configuration and process ope...
Page 16 - Documentation; Power on
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 16 of 18 5 Extended Documentation 5.1 Restart of AS 488/TM with Interface Module TPM 478 With each restart of the AS 488/TM the interface module TPM 478 will be para...
Page 17 - Limited; aktuell
Product Information November, 2001 AS 488/TM M02.02 Copyright © SIEMENS AG 1996-2001. All Rights Reserved. S79220-A0977-A-10-7637 Page 17 of 18 6 Limited Operating Performance No safety-relevant software faults are currently known; the known faults are assigned to fault class 3 and lower. Caution: W...