Siemens Advance Network Gateway - Manuals
Siemens Advance Network Gateway – User Manual in PDF format online.
Manuals:
User Manual Siemens Advance Network Gateway
Summary
Copyright Notice © 2002-2007 by Siemens All rights reserved. This publication is for information only. The contents are subject to changes without notice and should not be construed as a commitment, representation, warranty, or guarantee of any method, product, or device by Siemens. Reproduction or ...
Table of Contents Preface iii Technical Support v Safety Practices and Precautions vii Advance Network Gateway 1 Introduction Chapter 1: 1 Specifications 3 Installation 9 Introduction Chapter 2: 9 Unpacking & Inspection 10 Pre Installation Planning 11 Wall or Rack Mounting Installation 14 CE Ins...
Preface Audience & Purpose This manual is intended to introduce users to the Advance Network Gateway Ethernet (ANG_EN) unit that uses the ANCB Communications Board P/N 2020951-001. The manual includes complete instructions for proper and safe installation of the ANG_EN by installation personnel....
Technical Support Getting Help At Siemens Energy & Automation, Inc. we take pride in the on going support we provide our customers. This user’s manual should answer most of your technical questions; however, our technical support service provides a special “hot” line as an added source of inform...
Safety Practices and Precautions Safety First This product has been designed and tested in accordance with IEC Publication 1010-1, Safety Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. This manual contains information and warnings, which have to be follow...
Safety Practices and Precautions, Continued Correct Operating Voltage Before switching on the power, check that the operating voltage listed on the equipment agrees with the available line voltage. Danger Arising from Loss of Ground Any interruption of the grounding conductor inside or outside the e...
Chapter 1 Advance Network Gateway Introduction Overview The Advance Network Gateway with the Ethernet (ANG_EN) option connects equipment residing on an Advance Data Hiway to a high speed Ethernet communication system. The ANG_EN is a self-contained unit with its own power supply and electronics. It ...
Introduction, Continued Available Configurations The Advance Network Ethernet Gateway is available in the following configurations: Description SEA Part Number CSA/NRTL, Div 2, ADH to Ethernet, Wall Mount, CE (Copper) 2015840-001 CSA/NRTL, Div 2, ADH to Ethernet, Rack Mount, CE (Copper) 2015838-001 ...
Specifications Media Interface Advance Network Communication Board (ANCB): 10BASE-T RJ-45 STP connector Ethernet Specifications Data rate: 10Mbits/sec. Maximum Cable Length Per Ethernet Specifications Maximum length to adapter concentrator/hub: 100m (328 ft) Cable Type (minimum req.): AT&T D-ins...
Specifications, Continued Figure 1-2: Rack Mount Dimensions Dimension Table Figure 1-2 Description U.S. Inches Metric mm A Rack Height 6.97 177 B Rack Total Width 19 483 C Rack Mounting Holes Spacing 18.43 468 D Rack Depth Case Only 16.26 413 E Rack Handle 6.83 174 F Rack Depth with Handles 17.63 44...
Chapter 2 Installation Introduction Overview This chapter is intended for installation personnel. After completing the procedures, within this Chapter, the Advance Network Gateway will be ready for operation. Ensure that all AC Power (Mains) Specification requirements and advisories are met. Failure...
Unpacking & Inspection Instructions After opening the carton containing the unit, remove the unit from the carton and inspect it for damage that may have occurred during transportation. Points of inspection are: • Inspect exterior of unit for dents, chipped paint, scratches, etc. • Open unit and...
Pre Installation Planning Description This section provides information that can help you in preplanning your installation. Subsequent information includes examples of how an Advance Network Gateway (ANG_EN) can be used to physically extend a single loop of the Advance Data Hiway (ADH) and a Fiber o...
Pre Installation Planning, Continued Figure 2-2 : ANG_EN Installation Figure 2-2 illustrates how an ANG_EN can be used to physically extend a single loop of the Advance Data Hiway (ADH) by providing a conversion from the ADH media to Ethernet, and back to the ADH media. All segments of the system la...
Pre Installation Planning, Continued Figure 2-3 : ANG_EN Fiber Optics Installation Figure 2-3 shows an ANG_EN in a 10BASE-T to fiber optic installation. Fiber optic equipment including converters, hubs and interconnecting cable are not provided by Siemens. As shown in Figure 2-3, multiple ANG_EN uni...
Wall or Rack Mounting Installation Instructions The Advance Network Gateway Unit (ANG_EN) should be: • Installed in a location that is free from shock and vibration. • Protected from direct sunlight and extremes of temperature. • It is recommended that the ANG_EN be mounted within a shelter. This pr...
CE Installations Description This section should be used for installation sites that must conform to CE (Conformite Europeene) Certification. Typically, this does not apply to installations outside the EC unless the equipment was purchased with the explicit requirements and expectations that it shal...
CE Installations, Continued 3. A split ferrite must be clamped to Data Hiway cables and fixed immediately to the outside of the ANG_EN; use part number 1173000-013 ferrite contained in CE Installation Kit. This is required to meet the Conducted Immunity requirement for CE/EMC Heavy Industrial. All o...
Wiring Connections Description All input ac power and communications connections are made to connectors located on the chassis power supply assembly. To gain access to the assembly, open the front panel of the ANG_EN. For Zone 1 units refer to the Figure 1-4, Zone 1 Outline Drawing. Figure 2-4: Powe...
AC Power (Mains) Connections ANG_EN Power Supply The ANG_EN Power Supply can accept 90-264 VAC, 47-63 Hz inputs without the need for setting switches or jumpers. Installation personnel shall adhere to all AC Power (Mains) Specification requirements; see Chapter 1. Specifications, page WARNING 3. Fai...
AC Power (Mains) Connections, Continued Instructions, continued Step Action 7. Route input power, in accordance with pertinent electrical codes and regulations, to ANG_EN. To make the connections easier we have provided J1 as a removable connector. Simply grasp the top portion of the connector and p...
Data Hiway Connections Description This section provides instructions for connecting the ANG_EN to an existing Data Hiway. Figure 2-6: Data Hiway Connector Data Hiway Port 1 &2 Connections Pin 1-ADH-A+Pin 2-ADH-A-Pin 3- GroundPin 4-ADH-B+Pin 5-ADH-B-Pin 6- Ground Pin 1 Data Hiway Cable The Advan...
Data Hiway Connections, Continued More Information For technical information on the Data Hiway refer to Appendix A in the Optichrom Advance Library Set, Volume 2, Board Installation and Strapping Manual. Instructions Step Action 1. Place the ANG_EN AC Power Supply (Mains) circuit breaker to OFF. On ...
Ethernet Connections Description The DataNET Gateway connects to the Ethernet local area network via the RJ-45 STP connector located on the topside of the ANCB. Figure 2-7: RJ-45 STP Connector Before You Begin Read the following notes. 1. The 10BASE-T data cable requires a minimum of two twisted pai...
Ethernet Connections, Continued Installation Do not perform the following procedure until you have defined the IP and Subnetmask addresses; see Chapter 3, Data Communications Setup. Step Action 1. Connect the incoming Ethernet line from the Hub to the RJ-45 STP connector on the ANCB board. RJ45 STPC...
Chapter 3 Data Communications Setup Introduction Overview This chapter provides maintenance personnel instructions for configuring the Advance Network Gateway (ANG_EN). Once configured, the ANG_EN will “tunnel” Advance Data Hiway (ADH) messages across Ethernet to another ADH by way of an Maxum ™ Ana...
Configuring Your PC Description The Advance Network Gateway (ANG_EN) has a built-in utility for configuring the ANG_EN. The Windows ® HyperTerminal program, which resides on most PCs, can be used to access the utility. Other serial communication packages that support the following settings can also ...
Configuring Your PC, Continued 5. Click OK. The Connect to dialog box opens 6. From the Connect Using scroll list choose the COM port number you will be using on the PC to connect to the ANG_EN configuration port. 7. Click OK to save the selection. The COM Properties box opens 2000590-001 Data Commu...
Configuring Your PC, Continued 8. Scroll each field and select the following Port Settings: Bits per second: 57600 Data Bits: 8 Parity: None Stop bits: 1 Flow Control: None 9. Click OK. The Main Menu will appear. 10. Click File and choose Properties from the drop-down menu. The Advance Network Gatew...
Configuring Your PC, Continued 13. Click Terminal Settings button. The Terminal Settings dialog box will appear 14. Click OK to accept the default settings. The Advance Network Gateway Properties box will appear 16. Click ASCII Setup button. The ASCII Setup dialog box will appear 17. Click OK to acc...
Establishing a Connection Description Once your PC is set up, as described in Configuring Your PC, you are ready to connect to an Advance Network Gateway (ANG_EN). Getting Started … read through this Chapter prior to performing any procedures. Before You Begin 1. Ensure that the ANG_EN is not connec...
Establishing a Connection, Continued How to Log On The following procedure assumes that the Windows Hyper Terminal program residing on your PC has been configured, the ANG_EN is operational and the PC is connected to the ANG_EN. 1. Open Windows Hyper Terminal program on your PC or double click the s...
Establishing a Connection, Continued Remote Connection Log On If your PC is connected to the ANG_EN configuration port you can connect to any other ANG_EN on the same network if you know the IP address of the device. 1. Open Windows Hyper Terminal program on your PC or double click the shortcut icon...
Setting Network Address & Loop and Unit Numbers Description This section provides instructions to configure an Advance Network Gateway (ANG_EN) with its own Network Address. Before You Begin 1. Open Windows Hyper Terminal program on your PC; reference Configuring Your PC , page 26. 2. Connect an...
Setting Network Address & Loop and Unit Numbers, Continued Unit refers to a numeric number assigned to a device on the Advance Data Hiway (ADH). Typically an ANG device can have a unit number from 0 to 31. However, If the ANG is connected to an Advance Network Interface Unit (NIU), the ANG unit ...
Setting Network Address & Loop and Unit Numbers, Continued 3. Press ↵ Enter . The following message appears Configuration Change verified. Type: reset - to save configuration changes 4. To save your entry, at the Local > prompt type: reset 5. To configure the ANG_EN subnetmask, at the Local &...
Setting Network Address & Loop and Unit Numbers, Continued 10. Save all changes. At the Local > prompt Type: reset This forces the ANG_EN to save the Configuration Information and reboot using the new values. The ANG_EN has now been configured. To display the current settings, type at Local &...
Assigning an IP Address Overview Each Advance Network Gateway (ANG_EN) unit on a network must be assigned an IP address. This 32-bit number defines each ANG_EN’s network ID and host ID. The IP address is assigned by the user before the Gateway is physically connected to a network. See Setting Networ...
Editing the Address Translation Table Overview The Advance Network Gateway (ANG_EN) monitors the “local” ADH bus for messages with a “remote” destination address. The ANG_EN determines if the message destination is “remote” by searching it’s Address Translation Table (ATT). If the destination addres...
Editing the Address Translation Table, Continued Displaying the ATT The Address Translation Table (ATT) can be displayed using the Configuration Management routines. 1. Log on locally to the ANG_EN. 2. To display the entire ATT type at the Local > prompt: display all 3. To display a single Loop o...
Editing the Address Translation Table, Continued 4. To display the ATT by IP number type: display ip xxx.xxx.xxx.xxx Where xxx.xxx.xxx.xxx is the IP address. If you leave off the IP address, the IP portion will default to the value of the local ANG_EN. Note: 255.255.255.255 and 0.0.0.0 are not allow...
Editing the Address Translation Table, Continued 2. To delete all ATT entries associated with a single IP address type: del ip xxx.xxx.xxx.xxx Where xxx.xxx.xxx.xxx is the IP address in dotted decimal notation. Note: 255.255.255.255 and 0.0.0.0 are not allowed. 3. To delete all entries in the ATT ty...
Editing the Address Translation Table, Continued 4. To add entries to the ATT type: add adh loop unit Where loop is the ADH loop number (1 - 8) and unit is the ADH unit number (1-31). All parameters must be specified. You can only add entries that are local to the ANG_EN. If it is not directly conne...
Firmware Updates Description Periodically we will provide our ANG_EN users with firmware upgrades. Perform the following instructions to download a new ANG_EN firmware upgrade to the Communications board. A firmware upgrade will take approximately 5 minutes. Instructions The following procedure assu...
Firmware Updates, Continued 4. Click on Send Text File. The Send Text File dialog box will appear. 5. Under Files of type select All files (*.*). 6. Under File name type in the upgrade version file name (for this example Gateway.hex). This will start the down loading of the files. Once the download ...
Command Summary Description This section summarizes the command syntax for the Advance Network Gateway (ANG_EN) software. Adds an ADH Unit to the Address Translation Table add format: add adh loop unit Where loop is a number in the range 1- 8. Where unit is a number in the range 1-31. This command p...
Chapter 4 Troubleshooting Introduction Overview This chapter provides installation personnel with troubleshooting information to solve problems associated in the setup of the Advance Network Gateway. Chapter Highlights Before beginning the installation process read through this Chapter to familiariz...
ANCB Description Description The ANCB (Advance Network Communication Board) is the communications electronics for the unit. The ANCB plugs into the PCI slot located on the power supply assembly. A bracket fastens it to the chassis. See Figure 2-4 Power Supply/ANCB Assembly. J12 J4 10Base2 10BaseT J ...
More Information See ANCB LEDs Description and Operation, page 50. 2000590-001 Troubleshooting • 49
ANCB LEDs Description & Operation Description This section provides maintenance personnel with information on how to use the ANCB LEDs for troubleshooting the Advance Network Gateway (ANG_EN). Communications Board LEDs 50 • Troubleshooting 2000590-001
ANCB LEDs Description and Operation, Continued During normal operation the Green LED for ADHA or ADHB will blink to indicate either receive or transmit activity on the ANG_EN channel. If a message retry is sent the Yellow LED will blink. ADHA and ADHB - The ADHA and ADHB LEDs are status indicators. ...
ANCB LEDs Description and Operation, Continued The Green TX LED blinks whenever a message is transmitted on the Ethernet channel. The Green RX LED blinks whenever a message is received on the Ethernet channel. The Red CL LED indicates there was a collision on the Ethernet. Note: collisions are a nor...
Ethernet Troubleshooting Guide Description The most common problems associated with the Ethernet and how to correct them are given in the table below. Fault Probable Cause Collisions Excessive collisions are most often caused by a physical media problem such as: 1. missing or incorrect terminators (...
Ethernet Troubleshooting Guide, Continued Fault Probable Cause Jabber Error Jabbering can be caused by faulty NIC or driver, cabling, or grounding problems Possible causes (listed by highest probability): 1. Faulty Cable/Connectors 2. Ground problem - Induced noise 3. Faulty NIC or HUB Ghosts Error ...
Guide to Network Health Recommendations for Network Health There are no magic numbers for good, or bad, network parameters (such as: utilization and collisions). The parameters that are acceptable for a healthy network are determined by many variables. 1. Utilization should average less than 40%. If...
Obtaining Diagnostics Information Description You can access the following Diagnostic information from an Advance Network Gateway (ANG_EN). • Ethernet Network Status • ADH Channels Status • Error Log Before You Begin The following procedures assumes that the Windows Hyper Terminal program residing o...
Obtaining Diagnostic Information, Continued ADH Channel Information To display the current diagnostic information for the ADH channels: 1. Log on to the ANG_EN. 2. At the > prompt type: netstat adh (a or b) . The display shows the number of packets received, transmitted and the number of errors d...
Chapter 5 Parts Catalog Introduction Overview This chapter provides maintenance personnel with a list of replaceable parts and assemblies for the Advance Network Gateway (ANG_EN). Subsequent information includes how to remove and replace the replacement part or assemblies. How to Place an Order Part...
Available Parts Description The available ANG_EN assemblies and parts and applicable part numbers are shown below. Part Description Ordering Number Power Supply, Base Assembly 2015849-802 ANCB Communication Board; Ethernet to Data Hiway Gateway 2020951-801 Debug Port Extension Cable 2020914-001 Powe...
Power Supply Assembly Removal Instructions The following procedure removes the power supply assembly from the ANG_EN enclosure. Step Action 1. Open the front panel of the ANG_EN by loosening the four captive screws located on each corner; use 4mm Allen wrench. 2. Shut off the primary AC Power Supply...
Appendix Data Hiway Testing How to Test the Data Hiway Post Installation Test The following test procedure tests the Channel A and Channel B Data Hiway cable connections. These test procedures insures that the signal lines are correctly installed. Referenced testing points are CH A and CH B (+) and ...
How to Test the Data Hiway, Continued Measuring Shield Continuity Data Hiway shield lead continuity can be checked by performing the following procedures: Ground Data Hiway cable shields at only one end of each segment. This practice reduces ground loop noise. Step Procedure 1. With Data Hiway commu...
Glossary Definitions Overview This section defines important Terms. The Advance Network Gateway Ethernet (ANG_EN) is a wall- (or rack-) mounted unit that is self-contained with power supply and all electronics. It provides internal field termination points to connect standard Advance Data Hiway cabl...
Definitions, Continued A Late Collision is one that occurs after the first 64 bytes in a frame or packet. Since the smallest Ethernet frame (packet) is 64 bytes in length, late collisions will not be detected on small packets. Ethernet controllers do not retransmit packets with late collisions resul...
3 ChromLAN Gateway CGW – Elan Gateway EGW With the Gateways CGW and EGW, Siemens PGC302, RGC202 and PGC102 Gas-Chromatographs as well as the series 6 Continuous Gas Analyzers can be linked to an Ethernet network. The Gateway has 2 Serial Ports: There is a port for the Ethernet and a serial port for ...
3 Gateway Operation Requirements Siemens Chromatographs • Siemens Chromatographs communicating through the Ethernet Gateway must be equipped with a PCPU-2 (Part # C79458-L2232-A3). • PCPU – Control Software must be Version 9.0 or higher. Workstation / PC • Workstation-PC - with Ethernet port 10Mbit/...
3 Technical Gateway Data Housing 1/5 3/4 Size with Housing 132x120x42 [mm] / 5 x 4 x 1 1/8 (inch) Housing with Din-Rail mounting) Size without Housing 125x115x20 [mm] / 5 x 4 1/2 x 3/4 (inch) Storage Temperature -40 .. + 70 ° C / -40 ... 160 ° Power Supply Power 24V DC +/-20 % / 200mA Cable Connecti...
Siemens Manuals
-
Siemens HF35M630/01
User Manual
-
Siemens HF35M630/01
Installation Manual
-
Siemens 1015N-2MFM-1A
Manual
-
Siemens 108
User Manual
-
Siemens 11
User Manual
-
Siemens 1168
User Manual
-
Siemens 120 Series
User Manual
-
Siemens 125-1957
User Manual
-
Siemens 125-3584T
User Manual
-
Siemens 125-5033
User Manual
-
Siemens 140
User Manual
-
Siemens 175V
User Manual
- Siemens 1800C User Manual
-
Siemens 18inc Freezer Tower with Dispenser
User Manual
-
Siemens 18inc Wine Tower
User Manual
-
Siemens 1G03QB 630G
User Manual
-
Siemens 2 D SP
User Manual
-
Siemens 2000
User Manual
- Siemens 2005C User Manual
-
Siemens 2010 Tango
User Manual