Page 2 - Welcome; Thank you for purchasing your new Schweigen Isodrive system.
Page 2 Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety note...
Page 3 - Index
Page 3 Index 1. Welcome ........................................................................................................................................2 2. Your Safety ..............................................................................................................................
Page 4 - RECEIVING YOUR RANGEHOOD; Any damage or defects MUST be reported; Before Installation; Electrical Cord; MUST BE
Page 4 2. Your Safety RECEIVING YOUR RANGEHOOD Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAG...
Page 5 - Motor Features; • WARRANTY 10 YEARS; General Notes on Installation and Use; Recommended Installation Distance; recommended 4 to 5 metres
Page 5 This guide is for the installation of the Isodrive motor system after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual). NOTE: All PVC pipe and flexi ducting measurements are referring to inside measurements, unless otherwise me...
Page 7 - Isodrive Motor; Not included in the box:; NOTE
Page 7 Isodrive Motor Included in the box: 1. Isodrive 3200 motor Approx. 3 metre, 10amp cable and standard male plug 2. Fire resistant 250mm OD 1 PVC riser pipe NOTE: Cable cut-out at the both ends 3. Flexible ducting (250mm) Approx. 4 metres, 250mm (260mm OD 1 ) diameter 4. Flexible ducting (200mm...
Page 8 - Roof Installation; DO NOT
Page 8 Roof Installation Recommended duct length: minimum 4 metres, optimal 4-5 metres. Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other a...
Page 9 - IMPORTANT; MUST
Page 9 Figure 1 Roof Mount Option IMPORTANT For more flexible ducting instructions, refer to page 13. dektite 3200 motor 200mm flexible duct MUST keep taught 250-200mm reducer Connect to power supply 4. Installation Only use when connecting the motor to a single 200mm outlet on the rangehood. NOTE: ...
Page 10 - Through Wall Installation
Page 10 Minimum protrusion distance from wall Recommended to fix pipe to a support structure or strapping bracket (not included in mounting kit). Ensure power cable, pipe and cover plate slot is at the bottom. Wall cover plate (Optional - Part Number P2025) Power cable Through Wall Installation Moun...
Page 12 - Twin 200mm Outlet Installation Example (3200 kit required)
Page 12 4. Installation Figure 2 Roof mount option Twin 200mm Outlet Installation Example (3200 kit required) This is for use where one motor is to be used and there are two 200mm outlets. Try to keep length of flexible ducting as even as possible other wise motors will draw air off each other Ensur...
Page 13 - Optional Back Draft Shutter Installation Through Roof
Page 13 4. Installation Optional Back Draft Shutter Installation Through Roof • Cut 250mm flexible duct length to approximately 150mm to 200mm.• Assemble by fitting shutter assembly into the ducting.• Check to ensure the flaps close and open freely before assembling the bottom end of the ducting. 32...
Page 14 - Optional Back Draft Shutter Installation Through Wall
Page 14 4. Installation Optional Back Draft Shutter Installation Through Wall 3200 motor PVC storm pipe Cut existing ducting length to 150mm to 200mm and assemble to the shutter system. Secure with duct tape and clamp. Back draft shutter system Make sure the flaps are vertical Assemble existing duct...
Page 15 - Optional Weather Shield Installation Guide; Step 2
Page 15 4. Installation Optional Weather Shield Installation Guide Step 1 Remove Weather Shield (1 pc), P1128 Screws (2pcs) and P1128N Nuts (2pcs), Weather Shield Mounting Bracket (5 pcs) and P1124 Hex Head Screws (15pcs) from packaging. P1128N at the back P1128 Step 2 Remove plastic cover from Weat...
Page 16 - Flexible Ducting; A list of preferred Schweigen installers can be
Page 16 5. Flexible Duct Flexible Ducting Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. ...
Page 17 - Shallow Roof Space; Important Note
Page 17 5. Flexible Duct Shallow Roof Space In shallow roof spaces, do not crush or kink flexible ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 5. Figure 5 Figure 6 90 degree curve PVC or galvanise cur...
Page 18 - Securing Flexible Duct; Option 1
Page 18 Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using gaffer or electrical tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams...
Page 19 - Measurements for Isodrive 3200
Page 19 6. Measurements Measurements for Isodrive 3200 (Not to Scale) 5. Measurements 400 288 250.5 440 342 15.7 50 Figure 3 Dimensions in mm Isodrive 3200 weighs 8.3 kg without the PVC pipe.
Page 20 - Parts List for Isodrive 3200
Page 20 7. Parts List Parts List for Isodrive 3200 14 3 16 21 15 1 17 18 10 19 20 12 11 4 Figure 8 1 3 4 11 12 14 15 16 17 18 10 19 20 21
Page 21 - Number
Page 21 7. Parts List Parts List for Isodrive 3200 Number Part Number Description Quantity 1 P1114 Capacitor 4µF 1 3 P40112 Terminal Box – Box Base and Lid 1 4 P807 Terminal Block 1 11 P1101 Fan Top Spinning 1 12 P2011 M5X8 SUS Hex Nut Cap 4 14 P2003 Fan Guard 1 15 P1124 M4X12 Hex Washer Head S/S ST...