Page 2 - INDEX
INDEX Welcome 3 Important Safety Information 4 Description 7Operation 8Cleaning and Maintenance 10 Installation 14Condensation Information 28 Troubleshooting 29Technical Specifications 31 Disclaimer 34 Page 2
Page 3 - WELCOME; must be reported within 48 hours
WELCOME Thank you for purchasing this Schweigen IN appliance.To achieve the optimal performance from your appliance, and to avoid the risk of accident or damage, it is essential to read this manual before installation and first time use.This guide contains important information on the use and mainte...
Page 4 - IMPORTANT SAFETY INFORMATION
Page 4 IMPORTANT SAFETY INFORMATION Please read the instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual for future use or for subsequent owners. Check the appliance for damage after unpacking it. Do not connect or install t...
Page 5 - BEFORE INSTALLATION
IMPORTANT SAFETY INFORMATION Page 5 BEFORE INSTALLATION We recommend this appliance be installed or repaired by a qualified Schweigen Home Appliances technician. Please see our website www.schweigen.com.au for a list of our recommended installers.It is dangerous to modify any part of this appliance....
Page 6 - PRODUCT USE
IMPORTANT SAFETY INFORMATION Page 6 PRODUCT USE This product is designed for household use and should not be used for commercial applications.After use, always ensure that all controls are in the “OFF” position.When frying with a gas flame, take particular care not to allow the oil or grease in the ...
Page 7 - DESCRIPTION
Page 7 1. Connect the female plug to the Isodrive ® motor system 2. Male Plug (Main Power 240V)3. 150mm Outlet. Can be top or side mounted4. Remote5. Filter 6. Cover Panel with LED lights built-in7. Control Module, supplied with main unit only *IMPORTANT: The electronics MUST be accessible for servi...
Page 8 - OPERATION; REMOTE CONTROL USAGE
Page 8 OPERATION REMOTE CONTROL USAGE Starting the rangehood for the first time using the remote control:Put the safety switch ON (this switch is inside the main rangehood). Wait about 5 seconds for the circuit to test the memory. 1 2 3 4 The rangehood has a 4-speed remote control device. The button...
Page 9 - SYNCHRONISATION OF THE REMOTE; GENERATING A NEW
Page 9 OPERATION SYNCHRONISATION OF THE REMOTE CONTROL WITH THE RANGEHOOD If the remote control fails or the batteries run out, disconnect the rangehood using the safety switch inside the rangehood (which can be accessed from one of the filters) and replace the batteries, then synchronise the remote...
Page 10 - FILTERS; Latch A; CLEANING AND MAINTENANCE; Catch A
Page 10 FILTERS • For this appliance to function effectively, regular maintenance is a must. • The function of the filter is to absorb the grease particles emitted during cooking. • Blocked filters and heavy oil deposits restrict airflow and may cause the motor to overheat and become a fire hazard. ...
Page 11 - SURFACES; alcohol on the exterior of the
Page 11 CLEANING AND MAINTENANCE SURFACES The surface of the rangehood can be cleaned with warm soapy water and a soft sponge / cloth. • Never use abrasive detergents, scouring pads, steel wool or solvents on ANY part of this appliance. • Rinse with clean water and ensure that the appliance is compl...
Page 12 - heat for a short period of time after being switched off.
Page 12 CLEANING AND MAINTENANCE TYPE 3 (LED Plate):Replacing the LED Plate 11W (Mod. Modular) NOTE: Make sure the device is disconnected from the electrical power supply.Step 1Open the door of the Paradigma hood. Remove the filter and disconnect the light connector. Your rangehood may have multiple...
Page 14 - INSTALLATION; MATCH THE RANGEHOOD SIZE TO YOUR COOKTOP
Page 14 INSTALLATION MATCH THE RANGEHOOD SIZE TO YOUR COOKTOP It is important to make sure the rangehood is the correct size, the larger the surface area of your rangehood the better extraction results, see diagram below. INADEQUATE Rangehood smaller than cooking zone ADEQUATE Rangehood same size as...
Page 15 - with local laws and regulations.
Page 15 INSTALLATION IMPORTANTPlease check all State and Federal Laws in relation to the minimum–maximum heights, regulations concerning the expelling of air and install your rangehood in accordance with local laws and regulations. MIN 1200mm Optimal 1500mm MAX 1800mm 900mm
Page 16 - Danger
Page 16 INSTALLATION Danger All electrical wiring from the motor to the rangehood should be kept inside the roof space. Note * The Isodrive ® motor system does not include the roof seal kit, ring clamp or the support straps. Note Please see Isodrive ® installation guide for motor installation inform...
Page 17 - INSTALLATION GUIDE FOR CC-INARTS AND CC-SURF2S; Note
Page 17 INSTALLATION INSTALLATION GUIDE FOR CC-INARTS AND CC-SURF2S Before installing the rangehood, carefully open the doors (D), then remove the filters (E). Release power connection from the lighting incorporated in the holder, then remove (C) the fascia.1. On the ceiling, mark the outline of the...
Page 20 - Twin Motor Installation
Page 20 INSTALLATION MOTOR SYSTEM OVERVIEW GUIDE FOR CC-PARA4S, CC-PARA4W, CC-PARA3S, CC-PARA3W, CC-PARA2S, CC-PARA2W 1. Isodrive ® Motor/s 2. Roof Seal Kit (Dektite)*3. Support Straps*4. Attach Flexi Duct to Bell-Mouth Adaptor using ring clamp. Please DO NOT rip the ducting. 5. Isodrive ® Motor Pow...
Page 21 - EXAMPLE INSTALLATION FOR TRIPLE MODULES
Page 21 INSTALLATION EXAMPLE INSTALLATION FOR TRIPLE MODULES Sub Main Sub 3-Way Adaptor Min 300 Max 1000 Control Module Control Module Mains Plug Mains Plug Motor Power Lead Motor Power Lead Min 300 Max 1000 Main Sub Sub 3-Way Adaptor Min 300 Max 1000 Min 300 Max 1000 200 150 500 420 205 3-WAY ADAPT...
Page 22 - Important; EXAMPLE INSTALLATION FOR QUADRUPLE MODULES
Page 22 INSTALLATION 4-Way Adaptor Mounting points 550 700 205 150 200 Sub Sub Sub Main 4-Way Adaptor Control Module Mains Plug Motor Power Lead Min 300 - Max 1000 Min 300 - Max 1000 Measurements in mm. Measurements in mm. Important Please take note to the minimum and maximum spacing between each mo...
Page 23 - EXAMPLE INSTALLATION FOR TWIN MODULES
Page 23 INSTALLATION Sub 2-Way Adaptor Main Min 300 Max 1000 EXAMPLE INSTALLATION FOR TWIN MODULES 2-WAY ADAPTOR Measurements in mm. Measurements in mm. 155 315 325 150 200 Control Module Mains Plug Motor Power Lead Important Please take note to the minimum and maximum spacing between each module. T...
Page 26 - DUCTING VENT POSITION
Page 26 INSTALLATION DUCT CONVERTING DIMENSIONS FOR CC-PARA4S, CC-PARA4W, CC-PARA3S, CC-PARA3W, CC-PARA2S AND CC-PARA2W DUCTING VENT POSITION 265 130 ø 150 ø 150 360 360 Cutout 340 x 340 310 220 Measurements in mm. NOTE The ducting vent can be mounted either to the side or top of the unit. The ducti...
Page 27 - Please DO NOT crush or kink the ducting.
Page 27 INSTALLATION Please DO NOT crush or kink the ducting. 1. Crushed or kinked ducting creates sharp corners that creates turbulence. This reduces the size and efficiency of the ducting, lowers extraction and may cause excessive noise. BACK DRAFT FINS (FOR APPLICABLE MODELS)Should your Back Draf...
Page 28 - CONDENSATION INFORMATION; COOKING WITH INDUCTION
Page 28 CONDENSATION INFORMATION COOKING WITH INDUCTION COOKTOPS Cooking with an induction or similar cooktop, may produce condensation on the rangehood.Unlike basic electric or gas cooking, induction cooktops heat food and liquid instantly, which in turn, produces vapours rapidly. Because of this f...
Page 29 - TROUBLESHOOTING; appliance by yourself. Always
Page 29 TROUBLESHOOTING Before you contact the technical service department, make sure that the product is plugged in and power is supplied.Do not take any action that will damage the product. Check electric c onnection. V oltage o f the electric ne tw ork should be be tw een 220 - 240V , r angehood...
Page 30 - SERVICE; FAULTY INSTALLATION
Page 30 TROUBLESHOOTING SERVICE Lodging an Online Service RequestIn the event that the failure is not due to the faults mentioned in the Troubleshooting section, you can lodge an online Service Request. To lodge an online Service Request, visit our website www.schweigen.com.au/service-and-warranty a...
Page 31 - TECHNICAL SPECIFICATIONS
Page 31 TECHNICAL SPECIFICATIONS Model: CC-INARTSFeeding Voltage: 220-240V 50Hz Max Lamp Power: 10 x GLED Square 55 x 55mm 2.1W 12V 4000k 1710 2000 885 420 ø 200 7 00 1000 Cutout: 950 2000 Cutout: 1950 885 64 Min 210 - Max 335 1000 800 350 350 350 350 15 0 CC-INARTS
Page 34 - DISCLAIMER; DISPOSAL OF OLD APPLIANCES
Page 34 DISCLAIMER Under our policy of continuous product development, product specifications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale. All information supplied is to ...
Page 35 - NOTES