Page 2 - Welcome
Page 2 Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety note...
Page 3 - Index
Page 3 Index 1. Welcome _____________________________________________________________________________________2 2. Your Safety Receiving your rangehood ______________________________________________________________________ 4 Before Installation ________________________________________________________...
Page 4 - Before Installation; Electrical Cord; RECEIVING YOUR RANGEHOOD
Page 4 2. Your Safety This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person res...
Page 5 - Recommended Installation Distance
Page 5 2. Your Safety This guide is for the installation of the motor used in the Isodrive systems after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual). NOTE: All PVC pipe and SteelFlex ™ ducting measurements are referring to inside...
Page 7 - Isodrive Motor; NOTE
Page 7 3. Description Isodrive Motor Included in the box: 1. Isodrive 3200 motor Approx. 3 metre, 10amp cable and standard plug 2. Fire resistant 250mm outside dimension PVC riser pipe3. SteelFlex ™ safety ducting (250mm). Approx. 4 metres, 250mm (260mm outside dimension) diameter 4. SteelFlex ™ saf...
Page 8 - Roof Installation
Page 8 4. Installation Roof Installation Recommended duct length: 3200 motor — minimum 4 metres, optimal 4-5 metres. Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being seal...
Page 9 - IMPORTANT
Page 9 4. Installation dektite 3200 motor 200mm SteelFlex ™ duct MUST keep taught 250-200mm reducer Connect to power supply Only use when connecting the motor to a single 200mm outlet on the rangehood. NOTE: Prevent any cord bunching by pulling cord through from plug top end 250mm SteelFlex ™ duct (...
Page 10 - Through Wall Installation
Page 10 Minimum protrusion distance from wall Recommended to fix pipe to a support structure or strapping bracket (not included in mounting kit). Ensure power cable, pipe and cover plate slot is at the bottom. Wall cover plate (Optional - Part Number P2025) Power cable Through Wall Installation Moun...
Page 12 - Twin 200mm Outlet Installation Example (3200 kit required)
Page 12 4. Installation Twin 200mm Outlet Installation Example (3200 kit required) This is for use where one motor is to be used and there are two 200mm outlets. Try to keep length of SteelFlex ™ ducting as even as possible other wise motors will draw air off each other Ensure SteelFlex ™ ducting is...
Page 13 - Optional Backdraft Shutter Installation Through Roof
Page 13 4. Installation Optional Backdraft Shutter Installation Through Roof • Cut 250mm SteelFlex ™ duct length to minimum 400mm. • Assemble by fitting shutter assembly into the ducting. • Check to ensure the flaps close and open freely before assembling the bottom end of the ducting. 3200 motor PV...
Page 14 - Optional Backdraft Shutter Installation Through Wall
Page 14 4. Installation Optional Backdraft Shutter Installation Through Wall 3200 motor PVC storm pipe Cut existing ducting length to minimum 400mm and assemble to the shutter system. Secure with duct tape and clamp. Backdraft shutter system (optional) Make sure the flaps are vertical Assemble exist...
Page 15 - Optional Weather Shield Installation Guide; Step 2
Page 15 4. Installation Optional Weather Shield Installation Guide Step 1 Remove Weather Shield (1 pc), P1128 Screws (2pcs) and P1128N Nuts (2pcs), Weather Shield Mounting Bracket (5 pcs) and P1124 Hex Head Screws (15pcs) from packaging. P1128N at the back P1128 Step 2 Remove plastic cover from Weat...
Page 16 - Measurements for Isodrive 3200
Page 16 5. Measurements Measurements for Isodrive 3200 (Not to Scale) 5. Measurements 400 288 250.5 440 342 15.7 50 Dimensions in mm Isodrive 3200 weighs 8.3 kg without the PVC pipe. Figure 7: Measurements for Isodrive 3200 420 290 Ø400 Ø340 Ø250 15 50 205
Page 18 - Assembling SteelFlex
Page 18 6. SteelFlex ™ Safety Duct Assembling SteelFlex ™ Safety Duct SteelFlex ™ safety duct must be secured to a 250mm mounting pipe. 1. Slide the steel ring clamp over the end of the duct then insert the PVC riser pipe into the duct end Parts required: 1. SteelFlex ™ safety ducting 2. Steel ring ...
Page 19 - Shallow Roof Space
Page 19 6. SteelFlex ™ Safety Duct Shallow Roof Space In shallow roof spaces, do not crush or kink SteelFlex ™ ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 10. Important Note Please do not crush or ki...
Page 20 - Securing SteelFlex
Page 20 6. SteelFlex ™ Safety Duct Securing SteelFlex ™ Safety Duct SteelFlex ™ safety duct must be installed with supports at maximum intervals of 1.5 metres. SteelFlex ™ safety ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the int...
Page 21 - Parts List for Isodrive 3200
Page 21 7. Parts List Parts List for Isodrive 3200 14 3 16 21 15 1 17 18 10 19 20 12 11 4 1 3 4 11 12 14 15 16 17 18 10 19 20 21
Page 24 - Warranty; Disclaimer
Page 24 9. Warranty / Disclaimer Warranty (See warranty for more information) Isodrive motor has a 10-Year replacement product warranty.* The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any ...