Page 2 - Wash hands after handling.; Important Safety Measures
- 1 - The advanced surge capacity of the PI-1500 power inverter gives it the means to start most electrical devices including: color televisions, TV/VCR/dVd combinations, small microwaves, refrigeration electric coolers, small air conditioners. Warning: Handling the cord on this product or cords ass...
Page 3 - Do not use the inverter near flammable materials.
- 2 - • do not place the inverter in direct sunlight. The ideal air temperature for operation is between 30º and 105ºF. • Keep the inverter well ventilated in order to properly dis- perse heat generated while it is in use. • While in use, make sure there are several inches of clear- ance around the ...
Page 5 - If a device will not operate properly when first connected; Fastening the PI-1500 to a Flat Surface; For convenience, the PI-1500 can be fastened to a flat
- 4 - In the event of a power overload, the inverter is designed to automatically shut down. This safety feature prevents damaging the inverter while testing devices and equip- ment within the 1500-watt range. If a device will not operate properly when first connected to the inverter, turn the inver...
Page 8 - Connecting Inverter Cables; The inverter and the power source must be in the oFF; Connecting Inverter Cables to 12V Battery or 12V; : Failure to make the correct connections will result in
- - Connecting Inverter Cables The inverter and the power source must be in the oFF mode. Inverter Connection: 1. locate the positive and negative plastic terminals located on the left side of the inverter. Using a flathead or standard screwdriver, unscrew the positive (red) and negative (black) ter...
Page 10 - Using GFCI outlet; first to assure normal GFCI operation.
- 9 - Using GFCI outlet The GFCI (Ground Fault Interrupter) must be tested before each use. To test: 1. Turn the inverter oN.2. Push the "ReSeT" button located on the GFCI receptacle, first to assure normal GFCI operation. 3. Plug a nightlight (with an "oN/oFF" switch) or other produ...
Page 11 - LeDs and Audio Alarms
- 10 - inverter to reset. To reset: press the “TeST” button (stops flow of electricity to outlet) on the outlet face. Next, press the “RESET” button (restores flow of electricity to outlet) on the outlet face. LeDs and Audio Alarms Green – Power on Red light and/or Audio Alarm Current overload – Red...
Page 12 - Using the Inverter to operate a tV or Audio Device; The inverter is shielded and filtered to minimize signal
- 11 - power consumption. When the inverter is oFF, no lights appear. Using the Inverter to operate a tV or Audio Device The inverter is shielded and filtered to minimize signal interference. despite this, some interference may occur with your television picture, especially with weak signals. Below ...
Page 13 - Blown Fuse; If the fuse blows, take the inverter to a qualified techni; Power Source; operated with the inverter.
- 12 - Blown Fuse A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated. If the fuse blows, take the inverter to a qualified techni - cian for repair. Power Source Your average automobile or marine battery will provide an ample power supp...
Page 14 - Safety Features; The power input from the battery drops to approximately; How Do Power Inverters Work?
- 13 - Safety Features The led Indicator light will turn from GReeN to Red and the inverter will automatically turn itself off when: 1. The power input from the battery drops to approximately 10 volts. (When the power input drops to approximately 10.5 volts, an alarm will sound for an extended perio...
Page 15 - troubleshooting
- 14 - StAGe 2: The inverter then converts the 145-volts dC into 110-volts AC (household voltage) using advanced MOSFET transistors in a full bridge configuration. A "modi - fied sine wave" waveform is generated by this conversion. troubleshooting PRoBLeM: Low or No output Voltage Reason/Sol...
Page 16 - PRoBLeM: Audible Alarm on All the time; Recharge or replace battery to maintain adequate power; PRoBLeM: Device Does Not Work; Contact the device manufacture for start up surge and/or
- 15 - PRoBLeM: Audible Alarm on All the time Reason/Solution 1. Input voltage below 11 volts. Recharge or replace battery to maintain adequate power input. 2. Poor or weak battery condition. Recharge or replace battery. PRoBLeM: Device Does Not Work Reason/Solution 1. Device does not turn on. Try t...
Page 17 - Modified Sine Wave; LIMIteD WARRANtY; limited to, any implied warranty of merchantability or fit; with inverter
- 16 - SPeCIFICAtIoNS: Maximum Continuous Power ............................ 1500 wattsSurge Capability (Peak Power) ........................ 3000 WattsNo load Current draw ............................................. < 0.6AWave form ........................................... Modified Sine Wave...