Page 2 - Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove; REGENCY; ULTIMATE Direct Vent Freestanding Gas Stove.; UNIT SPECIFICATIONS
2 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove REGENCY ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted ...
Page 3 - TABLE OF CONTENTS; Page; Operating Instructions
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 3 TABLE OF CONTENTS Page Page System Data Chart ................................................................ 21Gas Connection .................................................................... 21High Elevation ...............................
Page 4 - SAFETY LABEL; Copy of Safety Label for U39 Gas Stove; Regency units are constantly be-
4 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove This is a copy of the label that accompa-nies each ULTIMATE Direct Vent Free-standing Gas Stove. We have printed acopy of the contents here for your review. SAFETY LABEL The safety label is located on the inside ofthe drop down pedestal door....
Page 5 - INSTALLATION
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 5 IMPORT ANT: SAVE THESE INSTRUCTIONS The ULTIMATE Direct Vent Freestanding GasStove must be installed in accordance withthese instructions. Carefully read all the in-structions in this manual first. Consult thebuilding authority having jurisdi...
Page 7 - Minimum ceiling
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 7 LOUVER INSTALLATION 1) Attach the top & bottom louvers to theside stove panel using 2 screws perside. INSTALLATION MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1) Ensure that structural members are not cutor weakened during installati...
Page 8 - EXTERIOR VENT TERMINAL LOCATIONS; Clearance to outside corner: with
8 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove EXTERIOR VENT TERMINAL LOCATIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window *(min. 12"/30cm) ...
Page 9 - RIGID PIPE VENTING COMPONENTS LIST
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 9 946-506/P Vent Guard (Optional) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Optional) - Riser Vent Terminal 946-523/P AstroCap Horizontal Cap 946-206 Vinyl Siding Standoff - AstroCap...
Page 10 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Alternate
10 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Termination Caps INSTALLATION The FPI AstroCap TM and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dur...
Page 11 - SAFETY; RIGID PIPE VENTING ARRANGEMENTS
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 11 Vent or Fireplace Products Interna-tional Ltd. 4) Installation other than as instructed bySimpson Dura-Vent and Fireplace Prod-ucts International Ltd. Warning: Always maintain re-quired clearances (air spaces)to nearby combustibles to pre-ve...
Page 12 - Option V; Option V
12 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max. With these options, maximum totalpipe length is 30 feet with minimumof 8 feet total vertical and maximum4 feet total horizon...
Page 13 - DV ST OVE HORIZONTAL VENT KIT
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 13 INSTALLATION DV ST OVE HORIZONTAL VENT KIT (# 946-116 & #946-216) INSTALLATION Minimum Installation Height: U39: 59-3/4" ( 1518mm) DV ST OVE HORIZONTAL VENT KIT DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-2...
Page 15 - Alternate Horizontal; Elbow; TERMINATION KIT; Planning Your Dura-Vent; COMPONENTS
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 15 Alternate Horizontal Termination Caps Dura-Vent Basic Horizontal Kit # 970 1 90 o Elbow 1 Wall Thimble Cover1 Horiz. Sq. Term. Cap DURA-VENT TERMINATION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent DirectVe...
Page 16 - HORIZONTAL; Diagram 1
16 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove NOTE: For Snorkel terminations in ABOVEgrade installations, follow national or lo-cal code requirements. Diagram 3a N o t e : R i s e rVent is only foruse in aboveg r a d e t e r m i -nations. U39: 59-3/4" (1518mm) Diagram 2 Note: a) The...
Page 17 - TERMINATION
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 17 Diagram 10 Diagram 9 Diagram 8 Diagram 7 Diagram 6 7) Install the Wall Thimble in the center of the10" square and attach with wood screws. 8) Slide the decorative wall thimble up to thewall surface being careful not to scratchthe paint a...
Page 18 - Offset Chart; CATHEDRAL CEILINGS; Slope
18 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INSTALLATION Diagram 11: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments. 4) Assemble the desired lengths of black pipeand elbows ne...
Page 19 - Support Extensions - Round; CONVERTING A; General; Converting a Factory Built Metal
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 19 INSTALLATION Using a level, make sure the support isvertical. If the support extends above theroof, cut it flush with the top of the roof. Nailthe support to the frame opening using (8)3" spiral nails or #8 x 1-1/2" screws. Note: If ...
Page 20 - Converting a Masonry Chimney
20 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Converting a Masonry Chimney Important: The existing masonry flueopening needs to have an area of at leasta 36 sq. in. to insure proper intake/ex-h a u s t f l o w . 1) Before cutting any holes, assemble the desired sections of black direct ...
Page 21 - System Data; GAS CONNECTION
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 21 U39-NG: For 0 to 2000 feet altitude U39-LP: For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: Natural Gas Propane Burner #32 #50 Max. Input - Natural Gas/Propane 38,000 Btu/h Min. Input - Natural Gas/Propane 20,000 Btu/h Supply Pressur...
Page 22 - CONVERSION FROM NATURAL GAS T O PROPANE; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
22 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove INSTALLATION Installer Notice:These instructions must be leftwith the appliance. Burner Orifice CONVERSION FROM NATURAL GAS T O PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversio...
Page 23 - GAS PIPE PRESSURE; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS; Valve Description
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 23 INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gassupply piping system by closing its individualmanual shut-off valve during any pressuretesting of the gas supply piping system at testpressures equal to or les...
Page 24 - LOG SET; The gas log kit contains the following:; AERATION
24 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove C)02-44 LOG SET INSTALLATION Read the instructions below carefullyand refer to the diagrams. If logs arebroken do not use the unit until they arereplaced. Broken logs can interfere withthe pilot operation. The gas log kit contains the follow...
Page 25 - FRONT DOOR
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 25 INSTALLATION Diagram 1 FRONT DOOR INSTALLATION (packaged separately) 1) Open the two side panels. 2) Slide the dooro n t o t h e t w ohinge pins mak- i n g s u r e t h e t w op i e c e s a r eflush together.See diagram 1. 3) Close the door. ...
Page 26 - Thermostat Wire Table; OPTIONAL WALL; WARNING: Electrical Grounding Instructions; OPTIONAL REMOTE; CAUTION
26 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 14 GA.16 GA.18 GA.20 GA.22 GA. 50 Ft.32 Ft.20 Ft.12 Ft. 9 Ft. Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length Thermostat Wire Table OPTIONAL WALL THERMOSTAT A wall thermostat may be i...
Page 27 - OPERATING INSTRUCTIONS; HOT
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 27 OPERATING INSTRUCTIONS 8) Rotate the HEAT control to adjust the flameheight higher or lower. SHUTDOWN INSTRUCTIONS 1) Use the Burner ON/OFF switch, thermo-stat or remote control to turn off the burner. 2) Push in the PILOT knob slightly and ...
Page 28 - Copy of the Lighting Plate instructions
28 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear somesounds from your gas appliance. This isperfectly normal due to the fact thatthere are various gauges and types ofsteel used within your appliance. Listedbelow ar...
Page 29 - MAINTENANCE; GENERAL VENT
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 29 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning.For relighting, refer to lighting instructions.Keep the burner and control compartmentclean by brushing and vacuuming at leastonce a year. When cleaning the lo...
Page 30 - Mitred Glass Replacement; Panel Glass Replacement; LOG REPLACEMENT; DOOR GASKET
30 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts under...
Page 31 - FAN MAINTENANCE; Electrical Grounding Instructions
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 31 MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace-ment, access to the fan is through the plate onthe rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fanaccess panel securely in place and cor-re...
Page 32 - REMOVING VALVE
32 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove REMOVING VALVE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. You shouldlay the panel on a soft cloth so it doesn't getmarked up. See diagram below. 4) Rem...
Page 33 - PARTS LIST; U39 MAIN ASSEMBLY
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 33 PARTS LIST 30) 630-021 Fan Access Panel 31) 730-019 Rear Panel 32) 730-565 Firebox Baffle/Restrictor Assy 33) 630-520 False Top Assembly 36) 936-194 Gasket-Starter Collar/Air Passage 37) * Gasket-Flue Collar/Starter Collar 38) 820-058 Pedest...
Page 34 - U39 BURNER & LOG ASSEMBLY
34 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove U39 BURNER & LOG ASSEMBLY 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob for Fan Speed Control 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control P...
Page 35 - U39 DOOR ASSEMBLIES
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 35 PARTS LIST U39 DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) ...
Page 36 - NOTES
36 Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ___________________________________...
Page 39 - WARRANTY
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove 39 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products Internat...
Page 40 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: _________________...