Page 3 - TABLE OF CONTENTS
Regency U38 ULTIMATE Freestanding Gas Heater 3 TABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ............................................. 14 Lighting Instructions ................................................ 14 Shutdown Instructions .....................................
Page 4 - SAFETY LABEL; Copy of the Safety Label for the U38 Freestanding Gas Stove
4 Regency U38 ULTIMATE Freestanding Gas Stove This is a copy of the label that accompanieseach ULTIMATE Freestanding Gas Stove. Wehave printed a copy of the contents here foryour review. The safety label is located on theinside of the drop down pedestal door. NOTE: Regency units are constantly being...
Page 5 - INSTALLATION
Regency U38 ULTIMATE Freestanding Gas Heater 5 INSTALLATION BEFORE YOU START Safe installation and operation of this appliancerequires common sense, however, we arerequired by the Canadian Safety Standardsand ANSI Standards to make you aware of thefollowing: IMPORT ANT: SAVE THESE INSTRUCTIONS The U...
Page 6 - OPTIONAL; Outside Air Through; CLEARANCES TO; DIMENSIONS
6 Regency U38 ULTIMATE Freestanding Gas Stove Side View Rear View Outside Air Through Rear of Pedestal Remove the blanking plate from the rear of thepedestal cover plate and bend the two tabs out90 degrees. Pipe fresh air into the pedestal areaby using duct pipe with a mesh grill at the outsidetermi...
Page 7 - VENTING; Venting Requirements; DRAFT HOOD; Vent Terminations
Regency U38 ULTIMATE Freestanding Gas Heater 7 INSTALLATION VENTING This heater is a vented appliance and must beconnected to a chimney/flue in accordancewith the installation codes. Note: The rear pedestal cover plate isonly required when outside air isbeing used. If using room air forcombustion, r...
Page 8 - GAS PIPE PRESSURE; GAS CONNECTION; System Data
8 Regency U38 ULTIMATE Freestanding Gas Stove 5) The pressure check should be carried outwith the unit burning and the setting shouldbe within the limits specified on the safetylabel. 6) When finished reading manometer, turn offthe gas valve, disconnect the hose andtighten the screw (clockwise) with...
Page 9 - CONVERSION FROM NATUAL GAS T O PROPANE; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Regency U38 ULTIMATE Freestanding Gas Heater 9 INSTALLATION Installer Notice:These instructions must be leftwith the appliance. Burner Orifice CONVERSION FROM NATUAL GAS T O PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit 730-969...
Page 10 - CONVERSION T O LOWER BTU RATING FOR U38; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS
10 Regency U38 ULTIMATE Freestanding Gas Stove LOG SET INSTALLATION Read the instructions below carefully andrefer to the diagrams. If logs are brokendo not use the unit until they are replaced.Broken logs can interfere with the pilotoperation. The gas log kit contains the following: a) 02-65 Rear L...
Page 13 - WIRING; Thermostat Wire Table; FINAL CHECK; CAUTION; WARNING: Electrical Grounding Instructions
Regency U38 ULTIMATE Freestanding Gas Heater 13 WIRING This heater does not require a 120V A.C.supply for operation. In case of a powerfailure, the burner switch and the optionalremote control/thermostat will continue to op-erate. However, a 120V A.C. power supply isneeded for the fan/blower operati...
Page 14 - OPERATING INSTRUCTIONS; HOT
14 Regency U38 ULTIMATE Freestanding Gas Stove OPERATING INSTRUCTIONS 3) Wait five minutes to allow gas, that mayhave accumulated in the main burner com- partment, to escape. If you smell gas, fol-low the instructions on the front of thismanual. If you don't smell gas continue on to the next step. 4...
Page 15 - COPY OF THE LIGHTING PLATE INSTRUCTIONS
Regency U38 ULTIMATE Freestanding Gas Heater 15 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS
Page 17 - MAINTENANCE; MITRED DOOR
Regency U38 ULTIMATE Freestanding Gas Heater 17 MAINTENANCE 4) Remove the door catch plate. 5) Remove glass retainers on sides first (3each side) then remove two center retain-ers. Note: Center glass retainers are gluedto center glass. 6) Remove glass from extrusions. When re-moving center glass, le...
Page 18 - FAN MAINTENANCE; Installing Glass; IMPORTANT; Disconnect power supply
18 Regency U38 ULTIMATE Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace-ment, access to the fan is through the accesspanel on the rear wall of the firebox. Note: The unit MUST NOT be operated without the fan access panel se-c u r e l y i n p l a c e a n...
Page 19 - REMOVING VALVE
Regency U38 ULTIMATE Freestanding Gas Heater 19 4) Remove the two outside frame pieces byremoving two screws per side. See dia-gram below. REMOVING VALVE If your valve requires maintenance or replace-ment, follow these instructions: NOTE: Always shut off the gas supply before removing the valve. 1) ...
Page 20 - PARTS LIST; U38 MAIN ASSEMBLY
20 Regency U38 ULTIMATE Freestanding Gas Stove PARTS LIST 24) 948-255 Door Latch c/w Hook 25) 910-250 Spill Switch 27) 910-233 Thermodisc - Fan Auto/On/Off 28) * Mounting Bracket - Fan Thermodisc 30) 750-010 Rear Panel 32) 730-565 Firebox Baffle 33) 560-535 False Top Assembly 34) 590-273 Flue Attach...
Page 21 - U38 BURNER & LOG ASSEMBLY
Regency U38 ULTIMATE Freestanding Gas Heater 21 U38 BURNER & LOG ASSEMBLY 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob - Fan Control Switch 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control Panel Decal 5...
Page 22 - U38 DOOR ASSEMBLIES
22 Regency U38 ULTIMATE Freestanding Gas Stove U38 DOOR ASSEMBLIES PARTS LIST 730-921 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * ...
Page 23 - WARRANTY
Regency U38 ULTIMATE Freestanding Gas Heater 23 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects eachunit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. i...
Page 24 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: _________________...