Page 2 - INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; REGENCY
2 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Rear Vent Direct Vent Gas Stove by FPI Fireplace Products International. The Regency Gas Series of hand crafted appliances has been designed to pro...
Page 3 - TABLE OF CONTENTS
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 3 TABLE OF CONTENTS Page Page Louver Installation ...................................................... 20Optional Wall Thermostat .......................................... 20Optional Remote Control Installation ......................
Page 4 - SAFETY LABEL; Copy of Safety Label for U37; DOOR SEAL ADJUSTMENT:
4 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater This is a copy of the label that accompanieseach ULTIMATE Rear Vent Direct Vent Free-standing Gas Stove. We have printed a copy of SAFETY LABEL the contents here for your review. The safetylabel is located on the inside of the drop...
Page 5 - INSTALLATION
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 5 IMPORTANT: SAVE THESE INSTRUCTIONS The ULTIMATE Rear Vent Direct Vent Free-standing Gas Stove must be installed in accord-ance with these instructions. Carefully read allthe instructions in this manual first. Consult thebuilding au...
Page 7 - EXTERIOR VENT TERMINAL LOCATIONS
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 7 INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air sup...
Page 8 - PLANNING YOUR VENTING INSTALLATION; IMPORTANT; VENTING; SAFETY
8 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater PLANNING YOUR VENTING INSTALLATION INSTALLATION IMPORTANT Read all instructions carefully before startingthe installation. Failure to follow these instruc-tions may create a fire or other safety hazard,and will void the warranty. B...
Page 9 - RIGID PIPE VENTING COMPONENTS LIST
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 9 INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent S e l k i r k Amerivent R Direct VentGS R Direct-Temp TM Direct Vent 6" Pipe Length...
Page 10 - RIGID PIPE VENTING - VERTICAL TERMINATIONS
10 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater INSTALLATION RIGID PIPE VENTING - VERTICAL TERMINATIONS FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES Offset to Vertical Terminations Vertical Terminations with Co-linear Flex System The shaded area in the diagram sho...
Page 11 - HORIZONTAL INSTALLATIONS; RESIDENTIAL AND MANUFACTURED HOMES/
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 11 INSTALLATION Diagram 2a HORIZONTAL INSTALLATIONS Diagram 1 *Dia 2a & 2b: As specified in CGA B149 Instal-lation Code. Local codes or regulations mayrequire different clearances. RESIDENTIAL AND MANUFACTURED HOMES/ MOBILE HOMES...
Page 13 - VERTICAL TERMINATION WITH
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 13 Flex Liner Exhaust Flue Air Intake Co-Linear Flex Adapter with Kit# 946-563 Co-linear DV Vertical Termination Cap # 946-529 Inner Pipe Adapter with Kit# 946-563 U37 Rigid Pipe Adaptor Part # 640-994 Outer Pipe with Kit# 946-563 o ...
Page 14 - General; Converting a Factory Built Metal
14 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater CONVERTING A CLASS-A METAL CHIMNEY OR MASONRY CHIMNEY TO A DIRECT VENT S Y S T E M General There are two different types of direct ventconversion systems listed below. Follow theappropriate directions for your installation. A ) Th...
Page 15 - Converting a Masonry Chimney
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 15 Converting a Masonry Chimney Important: The existing masonry flueopening needs to have an area of at leasta 36 sq. in. to insure proper intake/ex-haust flow. 1 ) Before cutting any holes, assemble the desired sections of black dir...
Page 16 - Conversion Kit from Natural Gas to Propane; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
16 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater INSTALLATION Burner Orifice Conversion Kit from Natural Gas to Propane THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit # 680-969 Contains: Qty. Part # Description 1 91...
Page 17 - Note: Prior to any pressure testing of
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 17 INSTALLATION AERATION ADJUSTMENT The burner aeration is factory set but may needadjusting due to either the local gas supply, airsupply or altitude. Natural Gas: 1/4" open Propane: 3/8" open The aeration adjustment gears a...
Page 19 - GAS PIPE PRESSURE TESTING; DOOR INSTALLATION; Valve Description
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 19 INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gassupply piping system by closing its individualmanual shut-off valve during any pressuretesting of the gas supply piping system at testpressures equa...
Page 20 - CAUTION
20 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired.Connect the wires as per the wiring diagrams.Note that the wires are connected to the "TH"on the gas valve. Use table below to determinethe maximum wir...
Page 21 - WIRING DIAGRAM; WARNING: Electrical Grounding Instructions
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 21 WIRING DIAGRAM This heater does not require a 120V A.C. supplyfor operation. In case of a power failure, theburner switch and the optional remote control/thermostat will continue to operate. However,a 120V A.C. power supply is nee...
Page 22 - OPERATING INSTRUCTIONS
22 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 ) Read and understand these instructions before operating this appliance. 2 ) Check to see that all wiring is correct and enclosed to prevent possible shock. 3 ) Check to ensure ther...
Page 23 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; FOR YOUR SAFETY READ BEFORE LIGHTING; DO NOT REMOVE THIS INSTRUCTION PLATE
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 23 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS 1) Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. FOR YOUR SAFETY READ BEFORE LIGHTING A ) This appliance has a pilot which must be l...
Page 24 - MAINTENANCE
24 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater MAINTENANCE MAINTENANCE INSTRUCTIONS 1 ) Always turn off the valve before cleaning. For relighting, refer to lighting instructions.Keep the burner and control compartmentclean by brushing and vacuuming at leastonce a year. When cl...
Page 25 - LATCH ADJUSTMENT; MITRED DOOR; Installing Glass; PANEL DOOR
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 25 MAINTENANCE LATCH ADJUSTMENT The door latch may require adjustment as thedoor gasket material compresses after a fewfires and after glass replacement. Turn thehandle on the adjustable catch to tighten orloosen the latch. GLASS REP...
Page 28 - PARTS LIST; U37 MAIN ASSEMBLY
28 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater PARTS LIST 1 ) 560-920 Louver Assy - Gold 560-921 Louver Assy - Brush Nickel 560-922 Louver Assy - Black 9 ) 730-560 Relief Door Assembly 10) 730-034 Mounting Plate Gasket 11) 730-517/P Fan Assembly (120 V) 910-331/P Fan Motor 12)...
Page 29 - U37 BURNER & LOG ASSEMBLY
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 29 PARTS LIST U37 BURNER & LOG ASSEMBLY 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob - Fan Control Switch 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob ...
Page 30 - U37 DOOR ASSEMBLIES
30 U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater U37 DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) ...
Page 31 - WARRANTY
U37 Regency ULTIMATE Rear Vent Direct Vent Freestanding Gas Heater 31 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects eachunit thoroughly before it leaves our facility. FPI Fireplace Product...
Page 32 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: __________________________...