Page 2 - TO THE NEW OWNER; his FPI Mobile/Manufactured Home Listed appliance comes; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
2 U32S-5 FPI Direct Vent Gas Insert TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI. The U32 Sunrise Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The U32S-NG5 and U32S-LP5 have been a...
Page 3 - TABLE OF CONTENTS
3 U32S-5 FPI Direct Vent Gas Insert TABLE OF CONTENTS OPERATING INSTRUCTIONS Operating Instructions ................................................ 22Lighting Procedure ...................................................... 22Shutdown Procedure ................................................... 22...
Page 4 - SAFETY LABEL
4 U32S-5 FPI Direct Vent Gas Insert SAFETY LABEL This is a copy of the label that accompanies each U32S-5 Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened. NOTE: FPI un...
Page 5 - REQUIREMENTS; MA Code - CO Detector
5 U32S-5 FPI Direct Vent Gas Insert REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part fo...
Page 6 - UNIT DIMENSIONS
6 U32S-5 FPI Direct Vent Gas Insert UNIT DIMENSIONS
Page 7 - INSTALLATION; General Safety Information
7 U32S-5 FPI Direct Vent Gas Insert IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need for a permit p...
Page 9 - VENTING; GAS CONNECTION; COMBUSTIBLE MANTEL
9 U32S-5 FPI Direct Vent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. The fl ue length must be...
Page 11 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
11 U32S-5 FPI Direct Vent Gas Insert CONVERSION KIT # 434-969 FROM NG TO LP U32S-5 using SIT 820 NOVA Gas Valve INSTALLATION THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Turn off the gas supply. 2) Remove the glass door. a) Release the two hooks ...
Page 12 - These instructions must be left
12 U32S-5 FPI Direct Vent Gas Insert INSTALLATION WARNING! Do not overtighten the screw. Recommended to grip the wrench by the short side. 13) Turn control knob to the “OFF” position. 14) Remove the black protection cap by hand from the high-low knob (Fig.1). 15) Insert a 5/32” or 4mm Allen wrench i...
Page 13 - Installation of the DC Sparker
13 U32S-5 FPI Direct Vent Gas Insert INSTALLATION 4) Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit. 5) Locate the ground lug at the receptical box, left of the unit. 6) Connect one end of the supplied green ground wire to the lug with the nut and ...
Page 14 - FINAL CHECK; CAUTION; OPTIONAL WALL THERMOSTAT; OPTIONAL REMOTE CONTROL
14 U32S-5 FPI Direct Vent Gas Insert The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi rep...
Page 15 - Green; Gas; WIRING DIAGRAMS; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
15 U32S-5 FPI Direct Vent Gas Insert PiezoIgnitor Black Red ToThermocouple IN Pilot Assembly Thermostat (Optional) (Millivolt) Remote Receiver (Optional) (Millivolt) Remote Transmitter (Optional) ON OFF Regency Burner ON OFF Ground Neutral Live Black Black Black Red Minimum Convection Air Temp. Swit...
Page 16 - PROPANE; Units and Units Equipped with DC Spark Boxes*
16 U32S-5 FPI Direct Vent Gas Insert For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual. INSTALLATION
Page 17 - GLASS CRYSTAL OR OPTIONAL CERAMIC STONES
17 U32S-5 FPI Direct Vent Gas Insert INSTALLATION GLASS CRYSTAL OR OPTIONAL CERAMIC STONES INSTALLATION ON BURNER Burner shown with Glass Crystals Burner shown with optional Ceramic Stones Spread the supplied Glass Crystals (or optional Ceramic Spa Stones) evenly over the burner. Ensure the crystals...
Page 18 - STANDARD
18 U32S-5 FPI Direct Vent Gas Insert INSTALLATION Diagram 3 Diagram 2 To remove the fl ush door, reverse the above steps. IMPORTANT NOTE: The chain must rest on TOP of the gas inlet pipe never under it. Diagram 1b Diagram 1a STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To i...
Page 19 - FACEPLATE AND DOOR FRAME INSTALLATION; Flip bottom louver up to close.
19 U32S-5 FPI Direct Vent Gas Insert INSTALLATION FACEPLATE AND DOOR FRAME INSTALLATION 3) Position faceplate on unit lining up screw holes on faceplate with screw holes on unit - secure with 4 screws. Note: Ensure that the fl anges on the sides of the fi rebox are on the outside, when installing th...
Page 20 - Completed Faceplate & Door Frame Installation
20 U32S-5 FPI Direct Vent Gas Insert 7) Install the door frame by hooking the top fl ange over the top of the glass door. 9) Run supplied 120V power cord along front face of masonry fi replace and plug into nearest receptacle. 10) Slide unit into fi nal position. 8) Lower the door frame gently into ...
Page 21 - Attach the Hearth Trim to the bottom of the faceplate side; OPTIONAL HEARTH TRIM INSTALLATION
21 U32S-5 FPI Direct Vent Gas Insert INSTALLATION The Hearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace. The faceplate is assembled fi rst and then the hearth trim is attached to the facepl...
Page 22 - OPERATING INSTRUCTIONS
22 U32S-5 FPI Direct Vent Gas Insert The glass panel may require cleaning after the unit has cooled down. DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Note: When the glass is cold and the a p p l i a n c e i s l i t , i t m a y c a u s e condensation and fog the glass. This condensation is nor...
Page 23 - COPY OF LIGHTING INSTRUCTION PLATE; MAINTENANCE; DO NOT REMOVE THIS INSTRUCTION PLATE
23 U32S-5 FPI Direct Vent Gas Insert COPY OF LIGHTING INSTRUCTION PLATE OPERATING INSTRUCTIONS slightly different rates which can cause "ticking" and "cracking" sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. A...
Page 24 - GENERAL VENT; GLASS GASKET; DOOR GLASS; Flush Glass Replacement
24 U32S-5 FPI Direct Vent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows: 1) Check the Venting System for corrosion in areas that are exposed to the elements. T h e s e w i l l a p p e a r a s r u s t...
Page 25 - FAN MAINTENANCE; FAN REMOVAL
25 U32S-5 FPI Direct Vent Gas Insert FAN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place. Caution: Label all wires prior to disconn...
Page 27 - REPLACING THE FAN
27 U32S-5 FPI Direct Vent Gas Insert MAINTENANCE 21) Disconnect green ground wire from power cord. REPLACING THE FAN Scrape off the old gasket from the Fan Access Panel, replace and reverse above steps to replace fan Hint : When pushing fan down onto pins - rub a dab of dishsoap on the grommet so it...
Page 28 - VALVE ASSEMBLY REPLACEMENT
28 U32S-5 FPI Direct Vent Gas Insert 1) Turn the unit off and allow it to cool down to room temperature. 2) Disconnect the power source and turn off the gas supply to the insert. 3) Open the bottom louver. 4) Remove the door frame by lifting out from the bottom and lift up off the glass door. 5) Rem...
Page 30 - PARTS LIST; MAIN ASSEMBLY
30 U32S-5 FPI Direct Vent Gas Insert PARTS LIST 1) 420-122 Fan Access Panel 2) 420-142 Gasket - Fan Access Panel 422-518/P Fan Assembly: 3) 910-215/P Fan Motor (120 V) 5) 910-750 Power Cord (120 V) 910-752 Wire Harness (intermediate) 7) 910-142 Thermodisc-Fan Auto ON/OFF 8) * Fan Switch Cover 9) * T...
Page 31 - BURNER ASSEMBLY
31 U32S-5 FPI Direct Vent Gas Insert PARTS LIST 1) 910-568 Valve - SIT NG / LP2) 904-430 Burner Ori fi ce Nat. Gas #42 904-163 Burner Ori fi ce LP # 54 3) 425-010 Pilot Holder4) 434-031 Pilot Shield Hood5) 425-007 Valve Tray 425-574/P Valve Assembly NG 425-576/P Valve Assembly LP 6) 425-008 Sunrise ...
Page 32 - FACEPLATE AND DOORFRAME
32 U32S-5 FPI Direct Vent Gas Insert PARTS LIST FACEPLATE AND DOORFRAME 3 1 2 1) 425-512 Door Bottom Assembly 2) 425-513 Frame Inside 3) 425-514 Faceplate Outside 4) 425-942 Hearth Trim 4
Page 33 - NOTES
Page 35 - WARRANTY
35 U32S-5 FPI Direct Vent Gas Insert WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is please...
Page 36 - Installer: Please complete the following information; Printed in Canada; FPI
36 U32S-5 FPI Direct Vent Gas Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: _________________________________________________________...