Page 2 - Thank-you for purchasing a; REGENCY FIREPLACE PRODUCT.
Regency Freestanding Woodstove 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you haveany questions about your product that are not covered in this manual, please contact the R...
Page 3 - TABLE OF CONTENTS; THE REGENCY FREESTANDING STOVE; Optional Accessories; OPERATING INSTRUCTIONS; SAFETY LABEL; INSTALLATION; Listed Components for Mobile Home Installation
Regency Freestanding Woodstove 3 TABLE OF CONTENTS THE REGENCY FREESTANDING STOVE Glass Installation .............................................................. 1 5 Optional Accessories - Pedestal Ash Drawer Kit .......................................... 1 5 - Bottom Shield Ashdrawer Kit ...........
Page 4 - HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,; CAUTION; TE OF MANUF
Regency Freestanding Woodstove 4 HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS. DO NOT REMOVE THIS LABEL FLOOR PROTECTION* F1100S WITH AIRMATE SHIELD LISTED SPACE HEATER, SOLID FUEL TYPE, ALSOSUITABLE FO...
Page 7 - RESIDENTIAL; ROOM AIR; Modular Part; Airmate OR; Things to consider when choosing options
Regency Freestanding Woodstove 7 INSTALLATION RESIDENTIAL INSTALLATION 1 ) Read all instructions before installing your Regency Stove. Install and use only inaccordance with these installation andoperating instructions. Be aware that localCodes and Regulations may override someitems in this manual. ...
Page 8 - MINIMUM CLEARANCE TO; Residential Installation “C” Vent (Single Wall)
Regency Freestanding Woodstove 8 INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a...
Page 9 - Minimum Alcove Clearance to Combustible Materials; Floor Protection
Regency Freestanding Woodstove 9 Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installedwith a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36" ...
Page 10 - STOVE ASSEMBLY; Airmate Assembly; Rear Heat Deflector Assembly
Regency Freestanding Woodstove 10 INSTALLATION Diagram 4 Diagram 2 Diagram 3 STOVE ASSEMBLY PRIOR TO INSTALLATION All units require either the pedestal or 4 legsattached to the base. The F1100 and F3100stoves require either the Airmate or Rear HeatDeflector on top of the stove. Clearances tocombusti...
Page 11 - STEP BY STEP; Leg and Bottom Shield Assembly
Regency Freestanding Woodstove 11 Horizontal Installation Standard Ceiling Installation 8 ) To complete your chimney installation, in- stall the double wall connector pipe fromthe stove’s flue collar to the chimney sup-port device. 9 ) If you are using a horizontal connector, the chimney connector s...
Page 12 - TABLE 1; MOBILE HOME INSTALLATION
Regency Freestanding Woodstove 12 INSTALLATION TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 0 2 x 15 o 4 x 15 o 2 x 30 o 4 x 30 o 2 x 45 o 4 x 45 o 0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0 1000-2000 12.5 13.5 14.5 15...
Page 13 - Canadian Installations*; LISTED COMPONENTS
Regency Freestanding Woodstove 13 INSTALLATION SIMPSON DURA-PLUSQty.Part # Description 1 6DVL8693 Connector Kit 1 6DP-MH9096 Mobile Home Kit ICC EXCEL 2100Qty.Part # Description 1 6CL48 48" Chimney length (also in 12",18", 24" lengths. 1 6RC Rain Cap 1 6RCS Spark Screen (for rain cap...
Page 14 - SECONDARY AIR TUBE
Regency Freestanding Woodstove 14 INSTALLATION Side View Front View Front View on the side channels. The notch goes onthe right hand side with the air holes facingforward toward the door opening. If thetube will not slide in easily, simply use a pairof vise grips or pliers and tap it into placewith ...
Page 15 - OPTIONAL; Bottom Shield Ash Drawer Kit; BRICK INSTALLATION
Regency Freestanding Woodstove 15 OPTIONAL ACCESSORIES The pieces listed below can be purchased andinstalled during the initial installation or added onlater. Freestanding - Large F3100 DOOR HANDLE Attach spring handle by rotating counter clock-wise onto rod. Ensure that the rod fits into theentire ...
Page 16 - WARNING: Electrical Grounding Instructions
Regency Freestanding Woodstove 16 Blower/Fan (846-515) 1 ) Remove the two screws from the top of the fan housing. 2 ) Slide the fan up into the rear heat shield. 3 ) After aligning holes, secure the fan to the rear heat shield using the two screwsremoved earlier. Note: The connection cord should not...
Page 17 - OPERATING
Regency Freestanding Woodstove 17 OPERATING INSTRUCTIONS 4 ) After about 15 to 20 minutes, when your wood has begun to burn strongly, adjustyour draft control down to keep the fire ata moderate level. WARNING: Never build a roaring fire ina cold stove. Always warm yourstove up slowly! 5 ) Once a bed...
Page 18 - ASH DISPOSAL; Safety Precautions; SAFETY GUIDELINES
Regency Freestanding Woodstove 18 ASH DISPOSAL During constant use, ashes should be removedevery few days. The Ash Drawer option fea-tures a convenient ash dump for easy removalof ash, see "Modular Options" on page 7. Safety Precautions 1 ) Do not allow ashes to build up to the loading doors...
Page 19 - MAINTENANCE; Ways to Prevent and Keep Unit; Glass Replacement
Regency Freestanding Woodstove 19 MAINTENANCE CREOSOTE When wood is burned slowly, it produces tarand other organic vapours, which when com-bined with moisture, form creosote. The creo-sote vapours condense in the relatively coolchimney flue of a slow burning fire. As a result,creosote residue accum...
Page 20 - PARTS LIST
Regency Freestanding Woodstove 20 PARTS LIST 1 ) 846-913 Door Assy-Sm/Med Gold F1100 (no glass) 846-915 Door Assy-Sm/Med Black F1100 (no glass) 846-910 Door Assy-Large Gold F3100 (no glass) 846-916 Door Assy-Large Black F3100 (no glass) 3 ) 846-302 Glass - Replacement - Small/Medium F1100 846-304 Gl...
Page 21 - S3100 STEP STOVE MAIN ASSEMBLY
Regency Freestanding Woodstove 21 PARTS LIST 1 ) 846-910 Door Assy-Large Gold S3100 (no glass) 846-916 Door Assy-Large Black S3100 (no glass) 3 ) 846-304 Glass - Replacement - Large - S3100 4 ) 936-243 7/8" Adhesive Tape Gasket 5 ) 846-920 Glass Retainer Clips (8/set) 6 ) * Screw - 1/4 - 20 x 3/...
Page 23 - FIREBRICK
Regency Freestanding Woodstove 23 70) 902-111 Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-122 Brick Partial: 1-1/4" x 2" x 4-1/2" 73) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 74) 802-147 Brick ...
Page 24 - NOTES
Regency Freestanding Woodstove 24 _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
Page 27 - WARRANTY
Regency Freestanding Woodstove 27 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality AssuranceTeam carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limitedlife...
Page 28 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: __________________________...