Page 2 - MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
Regency ® P40 Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P40 has been approved by Wa...
Page 3 - TABLE OF CONTENTS
Regency ® P40 Direct Vent Gas Fireplace 3 TABLE OF CONTENTS SIT Valve Description .................................................. 25Back-Up Battery Installation ........................................ 25Conversion Kit #502-969 from NG to LP ..................... 26Brick Panel Installation .........
Page 4 - INST; SAFETY LABEL
Regency ® P40 Direct Vent Gas Fireplace 4 INST ALLA TION This is a copy of the label that accompanies each P40-NG and P40-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the label on the unit and if...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® P40 Direct Vent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used i...
Page 6 - UNIT DIMENSIONS; Dimensions
Regency ® P40 Direct Vent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS Dimensions
Page 7 - INSTALLATION
Regency ® P40 Direct Vent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked...
Page 8 - Floor Mounted Fireplace
Regency ® P40 Direct Vent Gas Fireplace 8 INST ALLA TION INSTALLATION This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 45,000 (NG) Btu/h, 43,000 (LP) Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that...
Page 9 - CLEARANCES
Regency ® P40 Direct Vent Gas Fireplace 9 INST ALLA TION CLEARANCES The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that...
Page 10 - MANTEL CLEARANCES; MANTEL LEG CLEARANCES
Regency ® P40 Direct Vent Gas Fireplace 10 INST ALLA TION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of louver opening are shown in the diagram below. Note: A non-combustible mantel may be installed a...
Page 12 - TOP STANDOFF ASSEMBLY
Regency ® P40 Direct Vent Gas Fireplace 12 INST ALLA TION VENTING INTRODUCTION The P40 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby elimi...
Page 13 - EXTERIOR VENT TERMINATION REQUIREMENTS
Regency ® P40 Direct Vent Gas Fireplace 13 INST ALLA TION INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently c...
Page 14 - VENTING ARRANGEMENTS; Flue pipe
Regency ® P40 Direct Vent Gas Fireplace 14 INST ALLA TION VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency ® Direct Vent System These venting systems, in combination with the P40 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The lo...
Page 15 - RIGID PIPE VENTING SYSTEMS; BASIC HORIZONTAL & VERTICAL TERMINATIONS; Alternate
Regency ® P40 Direct Vent Gas Fireplace 15 INST ALLA TION INSTALLATION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in de...
Page 16 - RIGID PIPE VENTING COMPONENTS LIST
Regency ® P40 Direct Vent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Direct VentGS ® Direct-Temp TM 6" Pipe Length, Galvanized 1208 5DT-6 9" Pipe Length, Galvanized 120...
Page 17 - ALLOWABLE HORIZONTAL TERMINATIONS; ertical
Regency ® P40 Direct Vent Gas Fireplace 17 INST ALLA TION The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90 o elbow (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adapter (Part # 770-994) when using any Rigid Vent System (i...
Page 18 - Elbows; Option V
Regency ® P40 Direct Vent Gas Fireplace 18 INST ALLA TION H H1 V Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o elbows. Option V H + H1 A) 2' Min. 2' Max. B) 3' Min. 5' Max. C) 4' Min. 6' Max. D) 5...
Page 19 - Option V
Regency ® P40 Direct Vent Gas Fireplace 19 INST ALLA TION V H1 H V1 V1 V H Vertical Venting with Two (2) 90 o Elbows Vertical Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o elbows. Option V H V + V1 A) 0' Min. 2' Max. 1' Min. B) 1' Min. 4' Max. 2' Min....
Page 20 - ALLOWABLE VERTICAL TERMINATIONS
Regency ® P40 Direct Vent Gas Fireplace 20 INST ALLA TION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section. • Refer to "Vent Restrictor Positio...
Page 21 - UNIT INSTALLATION
Regency ® P40 Direct Vent Gas Fireplace 21 INST ALLA TION Diagram 7 Diagram 6 10) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 7) Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are maintained (Diagram 5...
Page 22 - Offset Chart
Regency ® P40 Direct Vent Gas Fireplace 22 INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation. Wal...
Page 23 - HORIZONTAL TERMINATION; ASTROCAP XL
Regency ® P40 Direct Vent Gas Fireplace 23 INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each ...
Page 24 - PILOT ADJUSTMENT; GAS LINE
Regency ® P40 Direct Vent Gas Fireplace 24 INST ALLA TION P40-NG SYSTEM DATA For 0 to 4500 feet altitude Front Burner Orifi ce: #44 Back Burner Orifi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.5"+/- 0.3"w.c...
Page 25 - GAS PIPE PRESSURE; SIT VALVE DESCRIPTION
Regency ® P40 Direct Vent Gas Fireplace 25 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2...
Page 27 - These instructions must be left
Regency ® P40 Direct Vent Gas Fireplace 27 INST ALLA TION INSTALLATION Control Module 17) Remove the Control Module, located behind the power module, by lifting it up off of the velcro. 18) Remove the J9 jumper using needle nose pliers, located under the heat shield. 19) Reverse steps 17 and 16. Be ...
Page 28 - IMPORTANT; BRICK PANEL INSTALLATION
Regency ® P40 Direct Vent Gas Fireplace 28 INST ALLA TION IMPORTANT Dangerous operating conditions may occur if the panels are broken. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. 3) Place the 2 small Back Brick Panels at the base of the fi reb...
Page 29 - LOG SET INSTALLATION
Regency ® P40 Direct Vent Gas Fireplace 29 INST ALLA TION LOG SET INSTALLATION INSTALLATION Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. Log kit (Part # 502-930...
Page 31 - Completed Log Set Installation
Regency ® P40 Direct Vent Gas Fireplace 31 INST ALLA TION 11) Fit log 03-37 on the 4th fender post and rest on the notch in log 03-33. 12) Place log 03-38 Left on the left side of the ember bed inbetween log 03-34 and log 03-35. 4th Fender Post 03-37 Ember Bed 03-38 Left 13) Place log 03-38 Right on...
Page 32 - STANDARD; AERATION
Regency ® P40 Direct Vent Gas Fireplace 32 INST ALLA TION Diagram 1 Diagram 3 STANDARD FLUSH DOOR NOTE: Install Finishing Trim prior to installing the Flush Door and Louvers. 1) The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of th...
Page 33 - WIRING DIAGRAM; FINISHING TRIM
Regency ® P40 Direct Vent Gas Fireplace 33 INST ALLA TION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to t...
Page 34 - OPERATING INSTRUCTIONS
Regency ® P40 Direct Vent Gas Fireplace 34 OPERA TION OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks....
Page 36 - COPY OF; TO TURN OFF GAS APPLIANCE; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency ® P40 Direct Vent Gas Fireplace 36 OPERA TION COPY OF LIGHTING PLATE INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used wi...
Page 37 - MAINTENANCE
Regency ® P40 Direct Vent Gas Fireplace 37 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use ...
Page 38 - DOOR GLASS; GLASS REPLACEMENT; FAN REPLACEMENT
Regency ® P40 Direct Vent Gas Fireplace 38 MAINTENANCE MAINTENANCE C A U T I O N : W e a r g l o v e s w h e n r e m o v i n g d a m a g e d o r b r o k e n glass. WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done b...
Page 39 - VALVE REPLACEMENT
Regency ® P40 Direct Vent Gas Fireplace 39 MAINTENANCE VALVE REPLACEMENT 1) Shut off the main gas supply and unplug the power to the ECS system. 2) Remove the main gas line pipe from the gas valve. 3) Remove logs and brick panels if installed. 4) Remove the fender by undoing the 2 screws, one on the...
Page 40 - DC SPARKER
Regency ® P40 Direct Vent Gas Fireplace 40 MAINTENANCE MAINTENANCE 15) Disconnect the compression fi tting at the solenoid valve. 16) Remove the solenoid valve from the main valve. 17) Disconnect the thermopile wires (TP/TH & TP) from the valve. See image below. 18) Undo the pilot tube from the v...
Page 42 - TS LIST; MAIN ASSEMBLY; PARTS LIST
Regency ® P40 Direct Vent Gas Fireplace 42 P A R TS LIST MAIN ASSEMBLY Part # Description 10) 502-528 Brick Panel Base (Set of 3) 502-901 Brick Panel Set Standard Brown 502-902 Brick Panel Set Standard Red 11) 502-040 Cast Iron Fender 502-075 Front Ember Tray 12) 502-033 Burner Front Cover 13) 948-4...
Page 43 - VALVE TRAY ASSEMBLY
Regency ® P40 Direct Vent Gas Fireplace 43 P A R TS LIST VALVE TRAY ASSEMBLY Part # Description PARTS LIST 120) 904-644 Orifi ce # 35 121) 904-568 Orifi ce # 44 122) 910-008 Pilot Assembly 125) 910-460 Valve NG - SIT 825 126) 910-937 Valve Solenoid - 3 Volt 127) 910-928 Wire Harness Solenoid Switch 12...
Page 45 - NOTES
Regency ® P40 Direct Vent Gas Fireplace 45 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________...
Page 47 - WARRANTY
Regency ® P40 Direct Vent Gas Fireplace 47 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is ...
Page 48 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Regency ® P40 Direct Vent Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________...