Regency P33-3 Zero Clearance Direct Vent Gas Fireplace To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P33-3 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a swit...
Page 3 - TABLE OF CONTENTS; Appliances; DIRECT VENT GAS FIREPLACE; Page
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace TABLE OF CONTENTS Louvers - Flush ........................................................ 29Double Screen Door ................................................. 29Bay Front (optional) .................................................. 29Bay Tri...
Page 4 - SAFETY LABEL
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace This is a copy of the label that accompanies each P33-3 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bot...
Page 5 - INSTALLATION
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The P33-NG3 or P33-LP3 Direct Vent Fireplace must be installed in accordance with these in-structions. Carefully read all the instructions in this manual fi rst. Consult the "authority having ju...
Page 7 - COMBUSTIBLE MANTELS; MANTEL LEG CLEARANCES
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace COMBUSTIBLE MANTELS INSTALLATION Clearances for Bay or Flush Front Because of the extreme heat this fi replace emits, the mantel clearances are critical. Com- bustible mantel clearances from top of unit are shown in the diagram below. Note: A non...
Page 8 - FRAMING AND FINISHING
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace 16-1/2” (419mm) Minimum 4" (102mm) 3" (76mm) 1-1/2" (38mm) 30” (762mm) 10" (254mm) dia. Hole through wall for Dura-Vent 1/2"(13mm)Drywall Top Header Opening for gas connection INSTALLATION 3) For exterior walls, insulate the ...
Page 9 - UNIT ASSEMBLY; VENTING INTRODUCTION
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly po-sitioned and attached to the top before the unit is put into position. Top Standoff Assembly The top standoffs are shipped in a fl at position and must b...
Page 10 - EXTERIOR VENT TERMINATION LOCATIONS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace EXTERIOR VENT TERMINATION LOCATIONS INSTALLATION . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air supply outlet ...
Page 11 - HORIZONTAL TERMINATIONS ONLY; Minimum; Important; nation Caps
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Wherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Riser Vent Termination Cap or the Dura-Vent Snorkel Termination Cap. 6-7/8" (173mm) dia. Flue pipe 4" (102mm) dia. flue pipe Wall Thimble (2 pc...
Page 12 - INSTALLATION PROCEDURES
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Termination Cap Wall Thimble 2 pieces (10" (254mm) Outer Diameter) 2” x 4” or 2” x 6” (21mm x 102mm or 21mm x 152mm) 6-7/8" (175mm) dia. air intake 4" (102mm) dia. flue pipe with spring spacer Screws (4 per connection) Screws (3 per ...
Page 13 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Flat Wall Installation
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop 24" (610mm) Pipe Length Adj.Pipe Length 11" - 14-5/8" (279mm - 372mm) 90 Elbow o Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff (Optional) Rigid Pipe...
Page 14 - RIGID PIPE VENTING COMPONENTS LIST
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent R Direct VentGS R Direct-Temp TM Direct Vent 6" Pipe Length, Galvanized 908 4DT...
Page 15 - RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall.• Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid pipevent systems...
Page 17 - RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o elbo...
Page 18 - Elbows; Option V; Option H
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows Option H V H + H1 + H2 A) 1 Max. 1' Min. 3' Max. B) 2' Max. 3' Min. 5' Max. C) 3' Max. 5' Min. 6' Max. D) 4' Ma...
Page 19 - Option V; Option H + H1 V
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Horizontal Venting with Three (3) 90 o Elbows Vertical Venting with Two (2) 90 o Elbows Option V H V + V1 A) 1' Min. 4' Max. 2' Min. B) 2' Min. 5' Max. 3' Min. C) 3' Min. 6' Max. 4' Min. D) 4' Min. 7' Max. 5' Min. E) 5' Min. 8' Max. 6' Min. Vert...
Page 20 - Option; Option V
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Vertical Venting with Three (3) 90 o Elbows Vertical Venting with Three (3) 90 o Elbows Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max. 2' Min. 4' Max. 5' Min. C) 3' Max. 3' Min.' 5' Max. 7' Min. D) 4' Max. 4'...
Page 21 - VERTICAL TERMINATION
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (11m) Air Intake Co-linear DV Vertical Termination Cap # 946-529 Co-Linear Flex Adapter with Kit# 946-563 Outer Pipe with Kit# 946-563 Inner Pi...
Page 22 - Venting Arrangements - Vertical Terminations
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Venting Arrangements - Vertical Terminations with Co-linear Flex System for bothResidential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. INSTALLATION
Page 23 - HORIZONTAL INSTALLATIONS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Diagram 3 HORIZONTAL INSTALLATIONS Diagram 1 b) Horizontal runs of vent must be sup- ported every three feet. Wall straps are available for this purpose. 5) Mark the wall for a 10" x 10" square hole. The center of the square...
Page 24 - GAS LINE; VERTICAL
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION GAS LINE INSTALLATION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve. The gas line connection ma...
Page 25 - HIGH ELEVATION; PILOT ADJUSTMENT
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 ps...
Page 26 - Conversion Kit from Natural Gas to Propane Model #431-969; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Conversion Kit from Natural Gas to Propane Model #431-969 for P33-3 using SIT 820 NOVA Gas Valve Remove the 2 screws, push Burner Assembly to the left and lift out. 7) Unscrew the pilot orifi ce with the allen key and replace with th...
Page 27 - OPTIONAL BRICK
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Note: The logs must not be in the unit. 3) Insert the back brick panel by carefully slip- ping it between the back wall of the fi rebox and the rear log bracket. OPTIONAL BRICK PANELS 1) Undo the bottom 2 door latches and open and re...
Page 28 - Optional Flush Trim
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Diagram 1 Diagram 3 STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Be care-ful that the glass g...
Page 29 - OPTIONAL BAY DOOR; The Bay louvers MUST be used; FLUSH LOUVERS; Optional Bay Trim; DOUBLE SCREEN
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the fl ush front. The standard fl ush door and glass must remain on the unit. 1) Hook the top of the bay door over the fl ush door fl an...
Page 30 - BAY LOUVERS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace 6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver. Push down to lock into place. Tighten the screws...
Page 31 - FULL SCREEN FRONT; Backside of Full
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace FULL SCREEN FRONT INSTALLATION 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Face Plate Bracket into the bottom of the unit, secure it into the pins located o...
Page 33 - Thermostat Wire Table; CAUTION
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length. Note: Preferable if the thermostat is installed on an interior wall. Regen...
Page 34 - WIRING DIAGRAM
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional...
Page 35 - INSTALLING THE OPTIONAL FAN; TO REMOVE THE FAN
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electri-cian. The n...
Page 36 - OPERATING INSTRUCTIONS; COPY OF THE LIGHTING PLATE INSTRUCTIONS
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS
Page 37 - Adjustment Wire: push to close; IMPORTANT
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yellower fl ame. The burner aeration is fact...
Page 38 - MAINTENANCE; General Vent Maintenance
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning th...
Page 39 - THERMOCOUPLE; Flush Glass Replacement; Bay Glass Replacement
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Dis-connect thermopile by loosening ...
Page 40 - REMOVING VALVE; INSTALLING VALVE
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace 10) Undo the pilot tube from the valve with a 7/16" wrench. REMOVING VALVE 1) Shut off the gas supply. 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door. 4) Remove the logs. 5) Remove the burner/gra...
Page 41 - PARTS LIST; Main Assembly; Part # Description
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace PARTS LIST Main Assembly Part # Description Part # Description Part # Description 1) 948-247 Door Handle 2) * Thermodisc Bracket 7) 910-428 Duplex Receptacle 8) 910-429 Box - Receptacle 9) 910-430 Cover - Receptacle 10) 904-687 Clamp Connector 1...
Page 43 - Burner & Log Assembly; Part
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace Burner & Log Assembly Part Description 53) 430-055 Gasket - Valve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 910-422 Flame HI/LOW Extension Knob 56) 910-190 Piezo Ignitor and Nut 433-574/P Valve Assy - Natural Gas 433-5...
Page 44 - Flush Front & Louvers; Description
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace PARTS LIST Flush Front & Louvers Part # Description Part # Description 117) 904-196 Magnet - 1' round 130) 430-924 Flush Glass Trim (set) - Gold (Option) 131) 430-926 Flush Glass Trim (set) - Brass (Option) 430-947 Flush Glass Trim (set) - B...
Page 45 - Part # Description
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace 430-930 Bay Front Complete 106) 940-079/P Side Glass 107) 936-243 Glass Gasket 108) 940-078/P Center Glass 110) * Bay Door Frame 111) 902-322 Bay Brick Panel - Standard 432-905 Bay Brick Panel - Standard Brown 432-906 Bay Brick Panel - Standard ...
Page 46 - NOTES
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _____________________________________...
Page 47 - WARRANTY
Regency P33-3 Zero Clearance Direct Vent Gas Fireplace WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products Internationa...
Page 48 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...