Page 2 - features of your Regency Fireplace.
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P121/P121LC/P121RC/ P131 is a hand crafted appliance and has been designed to provide you with all the warmth and charm ...
Page 3 - TABLE OF CONTENTS; Normal Operating Sounds of
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 3 TABLE OF CONTENTS Operating Instructions Operating Instructions ............................................... 29 Lighting Procedure .................................................... 29 Shutdown Procedure ...................
Page 4 - SAFETY LABEL
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 4 SAFETY LABEL This is a copy of the label that accompanies each REGENCY P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located...
Page 5 - INSTALLATION; YOUNG CHILDREN SHOULD BE; Note: These units are
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 5 INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location, page 8. b) C l e a r a n c e s t o C o m b u s t i b l e s , page 9. c ) Mantle Clearances, page 9. d) Framing & Finishing Requirements, page 10. e...
Page 6 - SPECIFICATIONS; Note: These units are
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 6 INSTALLATION SPECIFICATIONS P121 - See Thru P131 - Pier Note: These units are non-load bearing.
Page 9 - COMBUSTIBLE MANTELS; Mantel Clearances
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 9 INSTALLATION COMBUSTIBLE MANTELS CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams on page 8): WARNING: Fire hazard is an extreme risk if these clearances (air space) to c...
Page 10 - FRAMING AND FINISHING; Framing Dimensions
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 10 B C A FRAMING AND FINISHING CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of t...
Page 11 - Top Standoff Assembly
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 11 FLUEING INTRODUCTION The P121/P121LC/P121RC/P131 uses the "balanced flue" technology Co Axial system. The inner liner flue products of combustion to the outside while the outer liner draws outside combustion air into...
Page 12 - EXTERIOR FLUE TERMINATION LOCATIONS; Minimum clearances required for balanced flue terminals or
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 12 INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zeala...
Page 13 - FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS; Regency Direct Vent System (Flex) Horizontal Terminations Only
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 13 FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS Regency Direct Vent System (Flex) Horizontal Terminations Only These flueing systems, in combination with the P121/P121LC/P121RC/P131 Direct Vent Gas Fireplace, have been tested ...
Page 14 - Horizontal or Vertical Terminations; Flat Wall Installation
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 14 Simpson Dura-Vent Direct Vent GS SIMPSON DURA-VENT FLUEING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency. SIMPSON DURA-VENT FLUEING Horizontal or Vertical Terminations The Simpson Dura-...
Page 15 - FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM; Straight Out Horizontal Flueing; Option
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 15 INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) The diagram below shows examples of horizontal termination arrangements using one, two, or three 90 o elbows ...
Page 16 - Elbows; Elbows
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 16 INSTALLATION Diagram 3 Horizontal Flueing with Two (2) 90 o Elbows Option V H + H1 A) 1' (305mm) Minimum 2' (610mm) Maximum B) 2' (610mm) Minimum 5' (1.5m) Maximum C) 3' (914mm) Minimum 8' (2.4m) Maximum D) 4' (1.22m) Minimu...
Page 17 - FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM; Straight Up Vertical Flueing
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 17 INSTALLATION FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM (LPG & NG) Flue must be supported at offsets Maintain clearances to combustibles as listed on page 9. Firestops are ...
Page 19 - HORIZONTAL
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 19 INSTALLATION HORIZONTAL INSTALLATIONS Install the flue system according to the m a n u f a c t u r e r ' s i n s t r u c t i o n s i n c l u d e d with the components. 1) Set the unit in its desired location. Check to determ...
Page 21 - Offset Chart; for Regency AstroCap; Direct
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 21 INSTALLATION inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". 5) Slip the assembled liner and termination assembly through the thimble making sure...
Page 23 - GAS PIPE PRESSURE; GAS LINE; System Data; PILOT ADJUSTMENT
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 23 INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pres...
Page 24 - LOG INSTALLATION
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 24 INSTALLATION LOG INSTALLATION Read the instructions below carefully and refer to the dia- grams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. Log Kit # 3...
Page 26 - FINISHING TRIM
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 26 GLASS DOOR REMOVAL 1) Remove the 8 screws that secure the glass door. INSTALLATION 2) Pull the door slightly out on an angle and then lift up and pull completely out. 3) P131 & P121LC/P121RC Corner Model: Remove the 6 sc...
Page 27 - Thermostat Wire Table; WALL THERMOSTAT
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 27 Option 1: REMOTE CONTROL Can be used with Option 2 or 3 but not both. Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held tran...
Page 28 - WIRING DIAGRAM; Caution: Ensure that the wires do; Terminal Block Location
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 28 WIRING DIAGRAM Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring er- rors can cause improper and dange...
Page 29 - OPERATING INSTRUCTIONS; DO NOT BURN THE APPLIANCE; Gas Inlet
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 29 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure t...
Page 30 - General Flue Maintenance; COPY OF THE LIGHTING PLATE INSTRUCTIONS; TO TURN OFF GAS APPLIANCE; compartment clean. See installation and operating instructions; LIGHTING INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE; WARNING: If you do not follow these instructions exactly, a fire or
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 30 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacu- uming at least once a year. When ...
Page 31 - MAINTENANCE; GLASS REPLACEMENT
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 31 MAINTENANCE 2) Remove the Cap, and shine a flashlight down the Flue. Remove any bird nests, or other foreign material. 3) Check for evidences of excessive con- densation, such as water droplets forming in the inner liner, an...
Page 32 - INSTALLING VALVE
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 32 12) Lift the entire assembly out. 8) Remove the Side Base Brick Panels and finally the Long Base Brick Panels. MAINTENANCE Remove Left & Right Side Base Brick Panels Remove the 2 Long Base Brick Panels 9) Disconnect the ...
Page 33 - PARTS LIST
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 33 PARTS LIST P121 (SEE THRU) MAIN ASSEMBLY Part # Description Part # Description Part # Description 1) 360-528 Door Assy Front - Tempered 360-538 Door Assy Front - Ceramic (Optional) 2) 360-529 Door Assy Side - Tempered 360-53...
Page 38 - NOTES
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 38 ________________________________________________________________________________________________________________________________________________________________________________________________________________________________...
Page 39 - WARRANTY
Regency P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 39 WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or sp...
Page 40 - Printed in Canada
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.