Page 2 - . The L676E has been; MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; This Regency
Regency ® L676E Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The L676E has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model L676E has been approved...
Page 3 - TABLE OF CONTENTS
Regency ® L676E Direct Vent Gas Fireplace 3 TABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector(for the State of Massachusetts only) ............................ 5 UNIT DIMENSIONS Unit Dimensions ................
Page 4 - INST; SAFETY LABEL; COPY
Regency ® L676E Direct Vent Gas Fireplace 4 INST ALLA TION SAFETY LABEL This is a copy of the label that accompanies each L676E-NG and L676E-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the right hand side of the unit, visi...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® L676E Direct Vent Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used...
Page 6 - UNIT DIMENSIONS
Regency ® L676E Direct Vent Gas Fireplace 6 INST ALLA TION UNIT DIMENSIONS
Page 7 - INSTALLATION
Regency ® L676E Direct Vent Gas Fireplace 7 INST ALLA TION 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances check...
Page 9 - CLEARANCES; Clearance to Combustibles from:
Regency ® L676E Direct Vent Gas Fireplace 9 INST ALLA TION INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest ...
Page 10 - MANTEL CLEARANCES; MANTEL LEG CLEARANCES
Regency ® L676E Direct Vent Gas Fireplace 10 INST ALLA TION INSTALLATION MANTEL CLEARANCES Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram below. Note: A non-combustible mantel may b...
Page 11 - Non-Combustible Requirements
Regency ® L676E Direct Vent Gas Fireplace 11 INST ALLA TION INSTALLATION Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 45-7/8" high x 48" wide x 24-1/4" deep (1143mm x H 1219mm W x 616mm D). See Diagram 1. Also see Dia...
Page 12 - SIDE NAILING STRIPS; UNIT ASSEMBLY; TOP STANDOFF ASSEMBLY; FINISHING TEMPLATE
Regency ® L676E Direct Vent Gas Fireplace 12 INST ALLA TION INSTALLATION SIDE NAILING STRIPS The side nailing strips come attached to the unit. There are 3 plates, one on the top and bottom that can be folded out as required. UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Naili...
Page 13 - VENT RESTRICTOR
Regency ® L676E Direct Vent Gas Fireplace 13 INST ALLA TION Vent restriction is required for certain venting installations, see the diagrams in the "VentingArrangements" section to determine if they are required for your installation. The Vent Restrictor plate is located on the inside top of...
Page 14 - EXTERIOR VENT TERMINATION REQUIREMENTS
Regency ® L676E Direct Vent Gas Fireplace 14 INST ALLA TION EXTERIOR VENT TERMINATION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)C= Clearance to permanently closed window...
Page 15 - VENTING ARRANGEMENTS
Regency ® L676E Direct Vent Gas Fireplace 15 INST ALLA TION VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency ® Direct Vent System These venting systems, in combination with the L676E, have been tested and listed as a direct vent heater system by Intertek. The location of the termination ca...
Page 16 - RIGID PIPE VENTING SYSTEMS; BASIC HORIZONTAL & VERTICAL TERMINATIONS; IMPORTANT NOTE
Regency ® L676E Direct Vent Gas Fireplace 16 INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative bl...
Page 17 - ” X 8” RIGID PIPE CROSS REFERENCE CHART
Regency ® L676E Direct Vent Gas Fireplace 17 INST ALLA TION INSTALLATION Description Simpson Direct Vent Pro ® Simpson Direct Vent GS ® Discontinued Selkirk Direct-Temp™ Metal-Fab ® Sure Seal 6” Pipe Length, Galvanized 58DVA-06 1208 5DT-6 5D6 6” Pipe Length, Black 58DVA-06B 1208B 5DT-6B 5D6B 9” Pipe...
Page 18 - Offset Pipe Selection:; Use this table to determine offset pipe lengths.
Regency ® L676E Direct Vent Gas Fireplace 18 INST ALLA TION L676 & L900 Direct Vent Fireplace IMPORTANT NOTE • A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any ...
Page 19 - ALLOWABLE HORIZONTAL TERMINATIONS
Regency ® L676E Direct Vent Gas Fireplace 19 INST ALLA TION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adap...
Page 20 - Elbows; Option V
Regency ® L676E Direct Vent Gas Fireplace 20 INST ALLA TION Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. Option V H + H1 A) 2' Min. 4' Max. B) 3' Min. 5' Max. C) 4' Min. 6' Max. D) 5' Min. 7' Max. E) 6' Min. 8' Max. With ...
Page 21 - Option V
Regency ® L676E Direct Vent Gas Fireplace 21 INST ALLA TION Vertical Venting with Two (2) 90 o Elbows Vertical Venting with Three (3) 90 o Elbows Option V H V + V1 A) 2' Min. 2' Max. 3' Min. B) 2' Min. 10' Max. 6' Min. C) 3' Min. 6' Max. 4' Min. D) 4' Min. 7' Max. 5' Min. E) 5' Min. 8' Max. 6' Min. ...
Page 22 - ALLOWABLE VERTICAL TERMINATIONS
Regency ® L676E Direct Vent Gas Fireplace 22 INST ALLA TION VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearance...
Page 23 - UNIT INSTALLATION
Regency ® L676E Direct Vent Gas Fireplace 23 INST ALLA TION INSTALLATION Diagram 7 Diagram 5 7) E n s u r e t h a t t h e p i p e c l e a r a n c e s t o c o m b u s t i b l e m a t e r i a l s a r e m a i n t a i n e d (Diagram 5). Install the termination cap. Note: If installing termination on a v...
Page 24 - Offset Chart
Regency ® L676E Direct Vent Gas Fireplace 24 INST ALLA TION INSTALLATION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible ...
Page 25 - HORIZONTAL TERMINATION; Do not locate termination; ASTROCAP XL
Regency ® L676E Direct Vent Gas Fireplace 25 INST ALLA TION INSTALLATION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves sl...
Page 26 - SIT 845 VALVE DESCRIPTION
Regency ® L676E Direct Vent Gas Fireplace 26 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1...
Page 27 - BACK-UP BATTERY INSTALLATION; Note - Battery Hookup
Regency ® L676E Direct Vent Gas Fireplace 27 INST ALLA TION BACK-UP BATTERY INSTALLATION INSTALLATION 4) Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox). 3) Loosen the...
Page 28 - BRICK PANEL INSTALLATION; Interior Brick Panel Installation:
Regency ® L676E Direct Vent Gas Fireplace 28 INST ALLA TION BRICK PANEL INSTALLATION IMPORTANT: Must install 1 set of brick panels. The operation of this unit without the brick panels is prohibited. Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INT...
Page 29 - Exterior Brick Panel Installation:
Regency ® L676E Direct Vent Gas Fireplace 29 INST ALLA TION 7) Slide the left side brick panel into position and secure in place with the brick panel clip that was removed in step 3. 1) Ensure installation of the logs and glass door has been completed before installing the exterior brick panels. 2) ...
Page 30 - LOG SET INSTALLATION
Regency ® L676E Direct Vent Gas Fireplace 30 INST ALLA TION LOG SET INSTALLATION Installation of Interior Brick Panels must be completed before installing the log set. INSTALLATION Read the instructions below carefully and refer to the diagrams. If the logs are broken do not use the unit until they ...
Page 31 - Complete Log Set Installation
Regency ® L676E Direct Vent Gas Fireplace 31 INST ALLA TION INSTALLATION 6) Spread all of the Embers on the bottom brick panel around the burner tube and inbetween the front burner tube and the grate as shown. Separate platinum embers and place on the embers around the burner tube and inbetween the ...
Page 32 - WIRING DIAGRAM
Regency ® L676E Direct Vent Gas Fireplace 32 INST ALLA TION INSTALLATION WIRING DIAGRAM A receptacle is provided on the left hand side of the unit. 120 Volt AC power must be wired to the receptacle and the control module plugged in for the unit to operate fully. The front and rear burners will opera...
Page 33 - OPERATING INSTRUCTIONS; HOT
Regency ® L676E Direct Vent Gas Fireplace 33 OPERA TION OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leak...
Page 35 - OPERA; COPY OF LIGHTING PLATE INSTRUCTIONS; TO TURN OFF GAS APPLIANCE; DO NOT REMOVE THIS INSTRUCTION PLATE; STOP! Read the safety information above on this label.
Regency ® L676E Direct Vent Gas Fireplace 35 OPERA TION OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS A) BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor ...
Page 36 - MAINTENANCE; GLASS REPLACEMENT
Regency ® L676E Direct Vent Gas Fireplace 36 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning ...
Page 37 - BACK-UP BATTERY REPLACEMENT; CONTROL BOX REPLACEMENT
Regency ® L676E Direct Vent Gas Fireplace 37 MAINTENANCE BACK-UP BATTERY REPLACEMENT MAINTENANCE 2) Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield, close to the top of the fi rebox). 1) Loosen the 2 sc...
Page 39 - VALVE TRAY REPLACEMENT
Regency ® L676E Direct Vent Gas Fireplace 39 MAINTENANCE 1) Remove the exterior brick panels. 2) Remove the glass door. a. Release the 2 door latches on the left and right side at the top of the fi rebox. b. Swing the door out from the top and release the hinges on the left and right side of the door...
Page 42 - TS LIST; PARTS LIST; MAIN ASSEMBLY
Regency ® L676E Direct Vent Gas Fireplace 42 P A R TS LIST PARTS LIST MAIN ASSEMBLY Part # Description 1) 521-527 Flue Collar Inner Assembly 2) 502-008 Flue Collar Outer 5) 904-751 Cap Screws 1/4" x 4-1/2" 6) W260280 Gasket Top Relief Plate 7) 770-066F Top Relief Plate 8) 942-117 Top Relief ...
Page 43 - BURNER & LOG ASSEMBLY
Regency ® L676E Direct Vent Gas Fireplace 43 P A R TS LIST BURNER & LOG ASSEMBLY Part # Description 30) 521-015 Bracket Log Tray 31) 521-016 Log Tray 32) 521-042 Defl ector Log Tray 35) 948-455 Burner Rear NG/LP 36) 948-454 Burner Front NG/LP 37) 521-050 Grate 40) 521-063 Bracket Log Position 41)...
Page 44 - NOTES
Page 47 - WARRANTY
Regency ® L676E Direct Vent Gas Fireplace 47 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. i...
Page 48 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Regency ® L676E Direct Vent Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: _________________________________________________...