Page 2 - designed to provide you with all the warmth and charm of a wood; MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
HZ54 Regency Horizon TM Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The HZ54 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model HZ54 has been approved by ...
Page 3 - TABLE OF CONTENTS
HZ54 Regency Horizon TM Gas Fireplace 3 TABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 DIMENSIONS Unit Dimensions ..........................................
Page 4 - INST; SAFETY LABEL; COPY
HZ54 Regency Horizon TM Gas Fireplace 4 INST ALLA TION SAFETY LABEL This is a copy of the label that accompanies each HZ54-NG and HZ54-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the label on th...
Page 5 - REQUIREMENTS; MA Code - CO Detector
HZ54 Regency Horizon TM Gas Fireplace 5 INST ALLA TION REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in ...
Page 6 - DIMENSIONS; FACEPLATE & DOOR FRAME OVERLAY DIMENSIONS
HZ54 Regency Horizon TM Gas Fireplace 6 INST ALLA TION DIMENSIONS FACEPLATE & DOOR FRAME OVERLAY DIMENSIONS UNIT DIMENSIONS
Page 7 - INSTALLATION
HZ54 Regency Horizon TM Gas Fireplace 7 INST ALLA TION 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termina-tion. 11) Under no circumstances should this appliance be modi fi ed. Parts that have to be removed for servicing should be replaced prior to operat...
Page 8 - LOCATING YOUR; GAS FIREPLACE
HZ54 Regency Horizon TM Gas Fireplace 8 INST ALLA TION INSTALLATION This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 41,500 Btu/h (NG), after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the fl ame does not ...
Page 9 - CLEARANCES; Dimension; NON-COMBUSTIBLE REQUIREMENTS; Flue Clearances to Combustibles
HZ54 Regency Horizon TM Gas Fireplace 9 INST ALLA TION INSTALLATION Caution Requirements The top, back and sides of the fi replace are de fi ned by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances ...
Page 10 - MANTEL CLEARANCES; MANTEL LEG CLEARANCES; Drywall
HZ54 Regency Horizon TM Gas Fireplace 10 INST ALLA TION INSTALLATION MANTEL CLEARANCES Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: Drywall 2 0 12 6 4 8...
Page 12 - Description
HZ54 Regency Horizon TM Gas Fireplace 12 INST ALLA TION Framing Dimensions Description HZ54 A Framing Height 46-5/8” (1184mm) B Framing Width 60” (1524mm) C * Framing Depth * 22” (559mm) D Minimum Height to Combustibles 51” (1295mm) E Corner Wall Depth 72" (1829mm) F Corner Facing Wall Width 101...
Page 13 - SIDE NAILING STRIPS; UNIT ASSEMBLY; TOP STANDOFF ASSEMBLY; VENTING INTRODUCTION; IMPORTANT NOTE
HZ54 Regency Horizon TM Gas Fireplace 13 INST ALLA TION SIDE NAILING STRIPS The side and top nailing strips come attached to the unit. There is 1 plate on each side, and 1 on the top, that can be folded out as required. Nailing Strips UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the S...
Page 14 - VENT RESTRICTOR POSITION; ent Restrictor Settings for HZ54-NG; Vent Restrictor Set 1; Vent Restrictor Set 3
HZ54 Regency Horizon TM Gas Fireplace 14 INST ALLA TION INSTALLATION Vent restriction is required for certain venting installations, see the diagrams in the "VentingArrangements" section to determine if they are required for your installation. The Vent Restrictor plate is located on the insi...
Page 15 - EXTERIOR VENT TERMINATION REQUIREMENTS
HZ54 Regency Horizon TM Gas Fireplace 15 INST ALLA TION EXTERIOR VENT TERMINATION REQUIREMENTS INSTALLATION A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm)C= Clearance to permanently clos...
Page 16 - VENTING ARRANGEMENTS; Regency
HZ54 Regency Horizon TM Gas Fireplace 16 INST ALLA TION INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION (FLEX) Regency ® Direct Vent System These venting systems, in combination with the HZ54, have been tested and listed as a direct vent system by Warnock Hersey/Intertek. The location of th...
Page 17 - RIGID PIPE VENTING SYSTEMS; BASIC HORIZONTAL & VERTICAL TERMINATIONS; Alternate
HZ54 Regency Horizon TM Gas Fireplace 17 INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL & VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decorative black,...
Page 18 - ” X 8” RIGID PIPE CROSS REFERENCE CHART
HZ54 Regency Horizon TM Gas Fireplace 18 INST ALLA TION INSTALLATION 5” X 8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Page 20 - ALLOWABLE HORIZONTAL TERMINATIONS FOR HZ54-NG
HZ54 Regency Horizon TM Gas Fireplace 20 INST ALLA TION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS FOR HZ54-NG The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid ...
Page 21 - ALLOWABLE HORIZONTAL TERMINATIONS FOR HZ54-LP; ertical
HZ54 Regency Horizon TM Gas Fireplace 21 INST ALLA TION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS FOR HZ54-LP The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid ...
Page 22 - Elbows; Option V
HZ54 Regency Horizon TM Gas Fireplace 22 INST ALLA TION Horizontal Venting with Two (2) 90 o Elbows NG and LP Horizontal Venting with Three (3) 90 o Elbows NG and LP One 90 o elbow = Two 45 o elbows. Option V H + H1 A) 2' Min. 4' Max. B) 3' Min. 6' Max. C) 4' Min. 8' Max. D) 5' Min. 9' Max. E) 6' Mi...
Page 23 - Option V
HZ54 Regency Horizon TM Gas Fireplace 23 INST ALLA TION Vertical Venting with Three (3) 90 o Elbows NG and LP INSTALLATION Option V H + H1 V + V1 A) 2' Min. 2' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max. 7' Min. D) 5' Min. 6' Max. 8' Min. E) 6' Min. 8' Max. 9' Min. One 90 o elbow = Tw...
Page 24 - ALLOWABLE VERTICAL TERMINATIONS FOR HZ54-NG
HZ54 Regency Horizon TM Gas Fireplace 24 INST ALLA TION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section. • Refer to the "Vent Restrictor Posi...
Page 25 - ALLOWABLE VERTICAL TERMINATIONS FOR HZ54-LP
HZ54 Regency Horizon TM Gas Fireplace 25 INST ALLA TION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section. • Refer to the "Vent Restrictor Posi...
Page 26 - UNIT INSTALLATION
HZ54 Regency Horizon TM Gas Fireplace 26 INST ALLA TION INSTALLATION Diagram 7 Diagram 5 7) E n s u r e t h a t t h e p i p e c l e a r a n c e s t o combustible materials are maintained (Diagram 5). Install the termination cap. Note: If installing termination on a vinyl siding covered wall, a vinyl...
Page 27 - Offset Chart
HZ54 Regency Horizon TM Gas Fireplace 27 INST ALLA TION INSTALLATION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible sepa...
Page 28 - HORIZONTAL TERMINATION; ASTROCAP XL
HZ54 Regency Horizon TM Gas Fireplace 28 INST ALLA TION INSTALLATION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip i...
Page 30 - WIRING DIAGRAM
HZ54 Regency Horizon TM Gas Fireplace 30 INST ALLA TION WIRING DIAGRAM AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue fl ame or close for a more yellow fl ame. Minimum Air Shutter Opening: ...
Page 31 - CAUTION; Thermostat Wire Table; CAUTION
HZ54 Regency Horizon TM Gas Fireplace 31 INST ALLA TION INSTALLATION Optional WALL SWITCH (Included with Unit) 1) Run the supplied 10' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 10' of wire but if you wish to go with a lon...
Page 32 - GT REMOTE WIRING DIAGRAM; REFER TO CODING INSTRUCTIONS; DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.; Wall Mounting
HZ54 Regency Horizon TM Gas Fireplace 32 INST ALLA TION INSTALLATION GT REMOTE WIRING DIAGRAM Red wire Black wire Green wire Extra wires not used White wire spade connectors J-Box Receiver Wall Plate Slider Switch Low Voltage Junction Box REFER TO CODING INSTRUCTIONS IN THIS MANUAL I MPORTANT INSTAL...
Page 33 - OPTIONAL STAINLESS STEEL
HZ54 Regency Horizon TM Gas Fireplace 33 INST ALLA TION INSTALLATION OPTIONAL STAINLESS STEEL REFLECTIVE PANEL INSTALLATION 1) Position the left side panel in place and fi t the bottom tab into the slot at the bottom of the fi rebox as shown below. Repeat for right side panel. Fit side panel tab int...
Page 34 - GLASS CRYSTALS OR OPTIONAL CERAMIC STONES; OPTIONAL PEBBLE INSTALLATION
HZ54 Regency Horizon TM Gas Fireplace 34 INST ALLA TION INSTALLATION GLASS CRYSTALS OR OPTIONAL CERAMIC STONES INSTALLATION ON BURNER Evenly spread an appropriate amount of glass crystals o r g l a s s c r y s t a l s p l u s o p t i o n a l c e r a m i c s t o n e s o v e r t h e b u r n e r. E n s...
Page 35 - DOOR FRAME OVERLAY INSTALLATION
HZ54 Regency Horizon TM Gas Fireplace 35 INST ALLA TION FACEPLATE & DOOR FRAME OVERLAY INSTALLATION 1) Install the door frame overlay by hooking the top fl ange over top of the glass door, push in the bottom of the door frame overlay to secure in place. Door Frame Overlay Glass Door 3) Secure th...
Page 36 - Completed Faceplate & Door Frame Overlay Installation
HZ54 Regency Horizon TM Gas Fireplace 36 INST ALLA TION Completed Faceplate & Door Frame Overlay Installation IMPORTANT NOTE To ensure the gap between the door frame and the faceplate are equal from side to side you may need to slide the faceplate slightly to the left or right accordingly. Also ...
Page 37 - OPERA; OPERATING INSTRUCTIONS; IMPORTANT
HZ54 Regency Horizon TM Gas Fireplace 37 OPERA TION OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass i...
Page 38 - COPY OF LIGHTING PLATE INSTRUCTIONS; TO TURN OFF GAS APPLIANCE; DO NOT REMOVE THIS INSTRUCTION PLATE
HZ54 Regency Horizon TM Gas Fireplace 38 OPERA TION OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”. Knob cannot be turned from “PILOT” to ...
Page 39 - MAINTENANCE; GLASS REPLACEMENT
HZ54 Regency Horizon TM Gas Fireplace 39 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. 2) Clean appliance...
Page 40 - GLASS DOOR REMOVAL
HZ54 Regency Horizon TM Gas Fireplace 40 MAINTENANCE GLASS DOOR REMOVAL 1) Turn the unit off and allow it to cool down to room temperature. 2) Turn off the gas supply to the unit. 3) Remove the faceplate by lifting it up off the hinges on the sides of the fi rebox. 4) Remove the door frame overlay b...
Page 41 - DC SPARK BOX REPLACEMENT
HZ54 Regency Horizon TM Gas Fireplace 41 MAINTENANCE MAINTENANCE DC SPARK BOX REPLACEMENT 1) Remove the faceplate by lifting it up off the hinges on the sides of the fi rebox. 2) Remove the door frame overlay by swinging out 45 o from the bottom and lift up and out. 3) Remove the DC spark box bracke...
Page 42 - VALVE TRAY REPLACEMENT
HZ54 Regency Horizon TM Gas Fireplace 42 MAINTENANCE VALVE TRAY REPLACEMENT MAINTENANCE 1) Turn the unit off and allow it to cool down to room temperature. 2) Turn off the gas supply to the unit. 3) Remove the faceplate by lifting it up off the hinges on the sides of the fi rebox. 4) Remove the door...
Page 43 - INSTRUCTIONS BELOW FOR HZ54-NG UNIT ONLY.
HZ54 Regency Horizon TM Gas Fireplace 43 MAINTENANCE 6) Remove the burner tray by undoing the 2 screws inbetween the bot- tom cover and burner on the fi rebox. Carefully lift the burner up and out ensuring not to spill the glass crystals. Aerial View of the inside of the unit shown. MAINTENANCE ON/O...
Page 44 - INSTRUCTIONS BELOW FOR HZ54-LP UNIT ONLY.
HZ54 Regency Horizon TM Gas Fireplace 44 MAINTENANCE INSTRUCTIONS BELOW FOR HZ54-LP UNIT ONLY. 6) Loosen 6 screws that secure the burner extenders. on burner tray, located behind the burner on either side of the pilot assembly. 7) Lift out the 2 burner tray extenders. 8) After extenders have been re...
Page 45 - TS LIST; PARTS LIST; MAIN ASSEMBLY
HZ54 Regency Horizon TM Gas Fireplace 45 P A R TS LIST PARTS LIST MAIN ASSEMBLY 1 4 5 6 8 3 7 2 9 Part # Description 1) 910-074 Spark Generator Switch c/w Wire 2) 476-032 DC Spark Mounting Bracket 910-073 Spark Generator Battery Holder 910-078 Battery AA 910-363 White Wall Switch 910-366 White Switc...
Page 46 - ACCESSORIES
HZ54 Regency Horizon TM Gas Fireplace 46 P A R TS LIST Part # Description 30) 476-907 Re fl ective Stainless Steel Panels 31) 476-914 Faceplate & Door Frame Overlay - Black 476-917 Faceplate & Door Frame Overlay - Stainless Steel 476-919 Faceplate & Door Frame Overlay - Bright Stainless ...
Page 47 - WARRANTY
HZ54 Regency Horizon TM Gas Fireplace 47 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pl...
Page 48 - Installer: Please complete the following information; Printed in Canada; Register your Regency
HZ54 Regency Horizon TM Gas Fireplace 48 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: _____________________________________________________...