Page 2 - INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi repl...
Page 3 - TABLE OF CONTENTS
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Operating Instructions Operating Instructions .............................................. 32Lighting Procedure ................................................... 32Shutdown Procedure ........................................
Page 4 - SAFETY LABEL; Copy of Safety Decal for G36D-NG
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the b...
Page 5 - INSTALLATION
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 5 INSTALLATION CHECKLIST 1) Locate appliance a) Room location, page 6 b) Clearances to Combustibles, pages 6 -8. c) Mantle Clearances, page 8 d) Framing & Finishing Requirements, page 7 e) Venting Requirements, pages 10 - 17. 2) Assemble To...
Page 7 - Fire hazard is an extreme risk if
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 7 MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: FRAMING AND FINISHING 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front...
Page 8 - COMBUSTIBLE MANTELS
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 8 INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be instal...
Page 9 - Top Standoff Assembly; VENTING; Screw Facing
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 9 "C" Screw Position: For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed. UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correct...
Page 10 - EXTERIOR VENT TERMINATION LOCATIONS
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 10 INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air supply out...
Page 11 - Horizontal Terminations Only
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 11 VENTING UltraGlow Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The locatio...
Page 12 - RIGID PIPE VENTING COMPONENTS LIST
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 12 INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent R Direct VentGS R Direct-Temp TM Direct Vent 6" Pipe Length, Galvanized 908...
Page 13 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Alternate
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 13 Rigid Pipe Adaptor (Part# 510-994) Pipe Length Vertical Terminal Storm Collar (Part # 953) Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" Pipe Length Adj.Pipe Length 11" - 14-5/8" 90 Elbow o Horizontal Termination Cap (Pa...
Page 14 - RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 14 RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS ULTRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o elbow (two 4...
Page 16 - RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 16 RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using two 90 o elbows (two 45 o elbows equal one 90...
Page 18 - VERTICAL TERMINATION
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 18 INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for minimu...
Page 19 - Venting Arrangements - Vertical Terminations
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 19 INSTALLATION Venting Arrangements - Vertical Terminations with Co-linear Flex System for bothResidential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Page 20 - Below Grade Installation; HORIZONTAL
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 20 Diagram 4 6) The arrow on the vent cap should be pointing up. Insure that the 1-1/2" c l e a r a n c e s t o c o m b u s t i b l e m a t e r i a l s are maintained (Diagram 4). Install the termination cap. NOTE: For Snorkel terminations ...
Page 21 - VERTICAL
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 21 INSTALLATION Diagram 3 Diagram 5 Diagram 1 Diagram 2 Note: Apply sealant "Mill-Pac" to inner pipe and high temperature silicone seal-ant to outer pipe on every twist-lock joint. Diagram 5 Diagram 6 VERTICAL TERMINATION 1) Maintain th...
Page 22 - Do not locate termination; Offset Chart; for UltraGlow Direct Vent
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 22 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each...
Page 25 - LOG SET INSTALLATION
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 25 INSTALLATION 5) Position Log 02-53 across the cutouts in Logs 02-75 and 02-51 with the notch on the left side of the log fi tting into the 2nd grate tab. Cutouts 2nd Grate Tab LOG SET INSTALLATION Read the instructions below carefully and ref...
Page 28 - Flush Louvers; STANDARD FLUSH; Optional Flush Trim
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 28 Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 2 Be careful that the glass gasket does not roll up; there must be a gap between...
Page 29 - Thermostat Wire Table; WALL THERMOSTAT; REMOTE CONTROL; CAUTION
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 29 Thermostat Wire Table Option 3: WALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length. Note: Preferable if the thermostat is insta...
Page 30 - WIRING DIAGRAM
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 30 WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. (Do not cut the ground terminal off under any ci...
Page 31 - INSTALLING THE OPTIONAL FAN; To Remove the Fan
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 31 120 Volt AC power is needed for the fan switch and blower. A three wire power cord is provided to be plugged into the receptacle. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. 1) Shut the pow...
Page 32 - OPERATING INSTRUCTIONS; DO NOT ATTEMPT; IMPORTANT
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 32 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas l...
Page 33 - Copy of the Lighting Plate Instructions; NORMAL OPERATING
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 33 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, ...
Page 34 - MAINTENANCE; General Vent Maintenance; OR BRASS TRIM; THERMOCOUPLE; Flush Glass Replacement
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 34 MAINTENANCE 4) Make a periodic check of burner for proper position and condition. Visually check the fl ame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed servic...
Page 35 - Verify proper operation
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 35 13) Undo the pilot tube from the valve with a 7/16" wrench. 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 15) Remove the Piezo ignitor wire and push button assembly. 16) Undo the "gas out" ...
Page 36 - PARTS LIST; G36D MAIN ASSEMBLY
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 36 PARTS LIST G36D MAIN ASSEMBLY Part # Description Part # Description 1) 948-253 Door Handle 2) 510-026 Hinge Bracket - Left/Right 3) 948-045 Chain4) 948-115 Spring 6) 430-129 Receptacle Box Mount 7) 910-429 Box - Receptacle 8) 910-428 Duplex ...
Page 37 - G36D BURNER ASSEMBLY & LOG SET
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 37 G36D BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) 780-021 Gasket - Valve Access Plate NG/LP 786-574/P Valve Assy - Natural Gas 786-576/P Valve Assy - Propane 56) * Valve Tray - NG/LP 57) 910-378 Va...
Page 38 - G36D FLUSH FRONT ASSEMBLY
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 38 PARTS LIST G36D FLUSH FRONT ASSEMBLY Part # Description 131) 510-934 Flush Glass Trim (Set) - Brass 510-947 Flush Glass Trim (Set) - Steel 510-932 Flush Glass Trim (Set) - Gold 132) 904-196 Magnet (1" Round) 133) 780-069 Flush Louver - T...
Page 39 - WARRANTY
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 39 WARRANTY UltraGlow products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. UltraGlow is pleased to extend this one ye...
Page 40 - Installer: Please complete the following information; Printed in Canada; Register your UltraGlow online at
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...