Page 2 - The FireGenie; Remote Control MUST be installed by a qualified installer.; FCC Requirements; - Consult the dealer or an experienced radio TV technician for help.; Canadian Equipment Requirements
The FireGenie TM Remote Control is tested safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation.The FireGenie TM Remote Control is carefully engin...
Page 3 - The battery light (BAT. LOW) on the Receiver will NOT turn on when the
TABLE OF CONTENTS Matching Remote Control & Receiver ID Code ...................................................................... 4Remote Control Keypad ......................................................................................................... 5Remote Control Screen Display (LCD...
Page 4 - PROG; MATCHING REMOTE CONTROL & RECEIVER ID CODE
FPI FireGenie TM Remote Control Manual 4 The Remote Control handset has a set of unique ID codes that is pre-programmed into its memory. This set of ID codes helps to differentiate one Remote Control handset from another so that only the control box with a matching ID code will respond to the approp...
Page 5 - REMOTE CONTROL KEYPAD; TIME; Quick Reference Sticker; Remote Control
FPI FireGenie TM Remote Control Manual 5 The FireGenie TM is a custom designed Remote Control system with the following features: * Thermostatic Control;* An Automatic & Manual Mode for controlling unit ON and OFF;* A Program Mode for programming 2 time periods per day for all days of the week. ...
Page 6 - REMOTE CONTROL BASIC FUNCTIONS; Switching the Remote ON & OFF; Manual
FPI FireGenie TM Remote Control Manual 6 REMOTE CONTROL SCREEN DISPLAY (LCD) The LCD provides the following display features: 1. Flame Indication;2. Manual & Auto Mode Indication - MANUAL / AUTO;3. ROOM or SET Temperature Indicator;4. Day of Week; 5. Transmit Indicator ; 6. System St...
Page 7 - RECEIVER OPERATION; When ON Mode is selected, the flame will turn ON.
FPI FireGenie TM Remote Control Manual 7 RECEIVER OPERATION The Remote Receiver has 3 operating modes, namely ON, OFF and Remote. The operating mode is selected by means of a slide switch on the front panel of the Receiver. ON: When ON Mode is selected, the flame will turn ON. OFF: When OFF Mode...
Page 8 - AUTO MODE; Auto; MANUAL MODE
FPI FireGenie TM Remote Control Manual 8 AUTO MODE There is a 3-minute delay built into the Remote Control. This delay will affect the AUTO and PROG modes only. Which means the unit may not respond to specific instructions instantly when in either of these 2 modes. Note: Ensure the Remote Contro...
Page 9 - ADVANCED FUNCTION - PROGRAM MODE; Program; Time Period
FPI FireGenie TM Remote Control Manual 9 ADVANCED FUNCTION - PROGRAM MODE Note: Ensure the Remote Control has been turned ON in order to operate in this mode. Program mode is selected by pressing and releasing the AUTO/MAN button until the symbol PROG is shown on the LCD. The Remote Control will o...
Page 10 - Programming of Time Zone 1; SETTING THE PROGRAM MODE; ) Programming the On-Time of Time Period 1
FPI FireGenie TM Remote Control Manual 10 Time Zone 1 On-Time Programming of Time Zone 1 SETTING THE PROGRAM MODE The user can program two On-Times and two Off-Times as well as the Temperature settings for each day of the week. The PROG button is used to initiate the programming mode. The + and -...
Page 11 - Time Zone 1 Off-Time; ) Programming the Off-Time of Time Period 1; Programming the Set Temperature of Time Period 1
FPI FireGenie TM Remote Control Manual 11 Time Zone 1 Off-Time Programming of Time Zone 1 Time Zone 1 Set Temperature Programming of Time Zone 1 2) Programming the Off-Time of Time Period 1 Press and release the PROG button again to program the Off-Time for Time Period 1. Use the + and - but...
Page 12 - Time Zone 2 Off-Time; ) Programming the On-Time of Time Period 2; Programming the Off-Time of Time Period 2
FPI FireGenie TM Remote Control Manual 12 Time Zone 2 Off-Time Programming of Time Zone 2 Time Zone 2 On-Time Programming of Time Zone 2 4) Programming the On-Time of Time Period 2 Press and release the PROG button again to program the On-Time of Time Period 2. Use the + and - buttons to adj...
Page 13 - Time Zone 2 Set Temperature; ) Programming the Set Temperature of Time Period 2; a) Programming the Rest of the Week
FPI FireGenie TM Remote Control Manual 13 Time Zone 2 Set Temperature Programming of Time Zone 2 6) Programming the Set Temperature of Time Period 2 Press and release the PROG button one more time to program the Set Temperature of Time Period 2. Use the + and - buttons to adjust the temperat...
Page 14 - Mode has been activated.; ) Exiting Program Mode; The next day of the week flashes.
FPI FireGenie TM Remote Control Manual 14 The Day, Set Temperature and Prog 2 will all begin to flash simultaneuosly, indicating that Copy Mode has been activated. Pressing and releasing the + button will select the Day(s) of which the program is to copy to. Pressing and releasing the - ...
Page 15 - INSTALLING THE RECEIVER; Connect the output cable of the Receiver; Refer to the unit instruction manual; Installing the Receiver to a Wall Mount; Make sure the slide switch on the; Installation of
FPI FireGenie TM Remote Control Manual 15 INSTALLING THE RECEIVER 2. Connect the output cable of the Receiver to the valve. Refer to the unit instruction manual for wiring details. Installing the Receiver to a Wall Mount a. Secure the Receiver to the wall receptacle box.b. Use the screws provided to...
Page 16 - Installing the Receiver to a Fireplace
FPI FireGenie TM Remote Control Manual 16 5) Secure Heat Shield onto Receiver with 2 x #10 x 1/2" screws. Ensure the bottom of the Heat Shield is flush with the Receiver as shown in the diagram below. 6) Re-install Battery Pack and Control Switch by reversing steps 2 and 1 only. 3) Remove Receiv...
Page 17 - ) Secure Heat Shield with 2 screws as; Continuation For E21 Installation Only; ) Ensure wires do not touch base of
FPI FireGenie TM Remote Control Manual 17 4) Remove Bottom Glass Trim. 5) Place Remote Receiver under firebox. Remote Receiver Firebox 6) Place Heat Shield over Receiver. Heat Shield 7) Secure Heat Shield with 2 screws as shown below. Remote Receiver Continuation For E21 Installation Only 8) Ensure ...
Page 18 - TROUBLESHOOTING; Battery Replacement; Remote Control
FPI FireGenie TM Remote Control Manual 18 TROUBLESHOOTING If the Remote Control does not turn on: • Check to see that the Receiver is in the Remote position. • Ensure the batteries are correctly installed in the Receiver. • Check the batteries for replacement. When batteries are replaced, only the...
Page 19 - Displaying Temperature in Celsius or Fahrenheit
FPI FireGenie TM Remote Control Manual 19 Displaying Temperature in Celsius or Fahrenheit The default setting of the Remote Control is to display the temperature in Fahrenheit. However, the Remote Control can be changed to display temperature in Celsius by the following steps: 1. Ensure the Remote C...