Page 2 - UNIT SPECIFICATIONS
2 Regency FG39 FireGenie Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove by FPI FireplaceProducts International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provideyou with all the warmth a...
Page 3 - TABLE OF CONTENTS; Page; Flueing Arrangements - Horizontal
Regency FG39 FireGenie Freestanding Gas Stove 3 TABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ............................................ 23 Lighting Instructions ............................................... 23 Resetting the Unit .........................................
Page 4 - SAFETY LABEL
4 Regency FG39 FireGenie Freestanding Gas Stove SAFETY LABEL This is a copy of the label that accompanies each REGENCY FG39 Freestanding Gas Stove. We have printed a copy of the contents here for your review. The data plat is located on the inside of the drop down pedestal door. NOTE: Regency units ...
Page 5 - INSTALLATION
Regency FG39 FireGenie Freestanding Gas Stove 5 IMPORTANT: SAVE THESE INSTRUCTIONS The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instructions. Carefully read all the instructions in this manual first. Consult the building authority h...
Page 7 - Warning: Always maintain required
Regency FG39 FireGenie Freestanding Gas Stove 7 LOUVER INSTALLATION 1) Attach the top & bottom louvres to the side stove panel using 2 screws per side. INSTALLATION FLUEING INTRODUCTION The DV Stove Horizontal Flue Kit and the Simp- son Dura-Flue Room Sealed System Model DV- GS fluing systems, i...
Page 8 - EXTERIOR FLUE TERMINATION LOCATIONS; Minimum clearances required for balanced flue terminals or
8 Regency FG39 FireGenie Freestanding Gas Stove INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum Clearance (mm) a...
Page 9 - FLUEING ARRANGEMENTS
Regency FG39 FireGenie Freestanding Gas Stove 9 INSTALLATION FLUEING ARRANGEMENTS Vertical Terminations Using Dura-Flue Fluing System for Residential Manufactured and Mobile Homes The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs w...
Page 10 - DV STOVE HORIZONTAL FLUE KIT
10 Regency FG39 FireGenie Freestanding Gas Stove INSTALLATION DV STOVE HORIZONTAL FLUE KIT (#946-112) INSTALLATION Minimum Installation Height: FG39: 59-3/4" ( 1518mm) Review the following sequence of instruc- tions which are typical of most installations. The sequence may vary depending on wall...
Page 12 - TERMINATION KIT; Planning Your Dura-Flue; COMPONENTS
12 Regency FG39 FireGenie Freestanding Gas Stove Pipe Length Round Support Box/Wall Thimble (Part # 940) Round Support Box/ Wall Thimble (Part # 940) Vertical Terminal Storm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" (610mm) Pipe Length Adj.Pipe Length 11" - 14-...
Page 13 - HORIZONTAL
Regency FG39 FireGenie Freestanding Gas Stove 13 Diagram 5 Note: If installing termination on a siding cov- ered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. The four wood screws provided should be replaced with appropri...
Page 14 - TERMINATION
14 Regency FG39 FireGenie Freestanding Gas Stove Diagram 11: The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments. 4) Assemble the desired lengths of black pipe and elbows necessary to reach from ...
Page 15 - Offset Chart; CATHEDRAL CEILINGS; Support Extensions - Round
Regency FG39 FireGenie Freestanding Gas Stove 15 INSTALLATION Offset Chart Diagram 13 Notes: a) For multistorey vertical installations, a Ceiling Fire stop (Part # 963) is required at the second floor, and any subse- quent floor. Diagram 13. The opening should be framed to 10 " x 10" (254mm ...
Page 16 - GAS CONNECTION; AERATION; System Data
16 Regency FG39 FireGenie Freestanding Gas Stove INSTALLATION GAS CONNECTION The gas line should be rigid pipe. Copper may also be used if approved by AS5601-2004. The gas connection at the valve is 1/2 male. For minimum and maximum supply pressure see the System Data Table. GAS PIPE PRESSURE TESTIN...
Page 17 - Conversion Kit for NG to LPG Model #736-969
Regency FG39 FireGenie Freestanding Gas Stove 17 INSTALLATION Conversion Kit for NG to LPG Model #736-969 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Burner Orifice Conversion Kit 736-969 Contains: Qty. Part # Description 1 904-641 Burner Orifice #...
Page 18 - These instructions must be left with
18 Regency FG39 FireGenie Freestanding Gas Stove Installer Notice: These instructions must be left with the appliance. Minimum pressure: Remove one of the cables connected to the electric modulator. Keeping the nut (B) blocked, screw in the screw (C) to increase the pressure and screw it out to decr...
Page 19 - LOG SET; CONVERSION TO LOWER BTU RATING; THIS CONVERSION MUST BE DONE BY AN AUTHORIZED
Regency FG39 FireGenie Freestanding Gas Stove 19 LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit contains the following: a) 02-65 ...
Page 21 - FRONT DOOR; OPTIONAL
Regency FG39 FireGenie Freestanding Gas Stove 21 INSTALLATION Diagram 1 FRONT DOOR INSTALLATION (packaged separately) 1) Open the two side panels. 2) Slide the door onto the two hinge pins making sure the two pieces are flush to- gether. See diagram 1. 4) The latches should already be at the proper ...
Page 22 - WIRING; CAUTION: Label all wires prior to; Caution: Ensure that the wires do
22 Regency FG39 FireGenie Freestanding Gas Stove WIRING CAUTION: Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause im- proper and dangerous operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug f...
Page 23 - OPERATING INSTRUCTIONS
Regency FG39 FireGenie Freestanding Gas Stove 23 OPERATING INSTRUCTIONS FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with ...
Page 25 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency FG39 FireGenie Freestanding Gas Stove 25 COPY OF THE LIGHTING PLATE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING A ) BEFORE LIGHTING smell all around the appliance area for gas. B...
Page 26 - MAINTENANCE
26 Regency FG39 FireGenie Freestanding Gas Stove MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE. CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE. DO NOT USE THIS APPLIANCE...
Page 27 - Mitred Glass Replacement; Panel Glass Replacement; LOG REPLACEMENT
Regency FG39 FireGenie Freestanding Gas Stove 27 Mitred Glass Replacement Removing Glass: 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the...
Page 28 - FAN MAINTENANCE
28 Regency FG39 FireGenie Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and cor- rectly s...
Page 29 - REMOVING VALVE TRAY
Regency FG39 FireGenie Freestanding Gas Stove 29 MAINTENANCE 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. REMOVING VALVE TRAY If your valve requires maintenance or replace- ment, follow these instructions: NOTE: Always shut off the gas and dis- connect...
Page 30 - PARTS LIST; ELECTRONIC COMPONENTS PARTS LIST
30 Regency FG39 FireGenie Freestanding Gas Stove FG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131 910-915 910-082 910-088 910-089 910-084 910-526 910-080 910-521, 910-522, 910-523 910-909 Fan Resistor 910-915 Intermittent Pilot 910-082 Direct Spark Ignitor 910-089 Flame Cable 910-088 Spark Cable 910-084 Co...
Page 31 - FG39 MAIN ASSEMBLY
Regency FG39 FireGenie Freestanding Gas Stove 31 PARTS LIST 25) * Flex Pipe (3" ID) 26) * Clamp for Flex Pipe 29) * Air Deflector 30) 730-044 Rear Panel 31) 630-021 Fan Access Panel 32) 730-028 Firebox Baffle 33) 630-520 False Top Assembly 36) 936-194 Gasket - Starter Collar/ Air Passage 37) 936...
Page 32 - FG39 BURNER & LOG ASSEMBLY
32 Regency FG39 FireGenie Freestanding Gas Stove FG39 BURNER & LOG ASSEMBLY 57) * Switch Plate 730-574/P Valve Assembly - NG 60) 910-378 Valve - S.I.T. - NG 904-688 #32 Orifice - N.G. 936-170 Orifice Gasket 66) 910-038 Pilot Assy - S.I.T. - 3 Flame NG 910-039 Pilot Assy - S.I.T. - 3 Flame LPG 67...
Page 33 - FG39 DOOR ASSEMBLIES
Regency FG39 FireGenie Freestanding Gas Stove 33 PARTS LIST FG39 DOOR ASSEMBLIES Part # Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic Paper 106) 940...
Page 34 - NOTES
34 Regency FG39 FireGenie Freestanding Gas Stove ___________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________...
Page 35 - WARRANTY
Regency FG39 FireGenie Freestanding Gas Stove 35 WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or spillage caused by environmen...
Page 36 - Printed in Canada
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.