Page 3 - TABLE OF CONTENTS; Page; Operating Instructions; Fluing: Residential and Manufactured
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 3 TABLE OF CONTENTS Page Page Operating Instructions Operating Instructions ............................................... 19 Lighting Procedure .................................................... 19 Resetting the Unit ......................
Page 4 - DATA PLATE
4 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater This is a copy of the label that accompanies each REGENCY Rear Flued Room Sealed Free- standing Gas Stove. We have printed a copy of DATA PLATE the contents here for your review. The data plate is located on the inside of the drop down pe...
Page 5 - BEFORE YOU START; INSTALLATION; GENERAL SAFETY
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 5 INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AUTHOR- IZED SERVICE PERSON. THIS AP- PLIANCE SHOULD BE INSTALLED, REPAIRED, INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY AN AUTHORIZED SERVICE PER- SON. MORE FREQUENT CLEAN- ING MAY BE REQUI...
Page 7 - EXTERIOR FLUE TERMINATION LOCATIONS; Minimum clearances required for balanced flue terminals or
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 7 INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances according to AS5601-2004 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum Cl...
Page 8 - IMPORTANT; Warning: Always maintain required
8 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater PLANNING YOUR FLUING INSTALLATION INSTALLATION FLUING The Regency Room Sealed System (Horizontal Termination Kit (946-110) and the Vertical Ter- mination with the Co-linear Flex System in combination with the REGENCY Room Sealed- Rear Fre...
Page 9 - FLUING ARRANGEMENTS - VERTICAL TERMINATIONS
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 9 INSTALLATION FLUING ARRANGEMENTS - VERTICAL TERMINATIONS FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES Offset to Vertical Terminations If connecting to a Dura-Vent sys- tem, the Adapter to Dura-Vent # 640-994 is required. Ver...
Page 10 - HORIZONTAL INSTALLATIONS; RESIDENTIAL AND MANUFACTURED HOMES/
10 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater INSTALLATION Diagram 2 HORIZONTAL INSTALLATIONS Diagram 1 *Dia 2: Local codes or regulations may require different clearances. RESIDENTIAL AND MANUFACTURED HOMES/ MOBILE HOMES INSTALLATIONS You will require the following components with ...
Page 13 - Conversion Kit for NG to LPG Model #516-969
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 13 INSTALLATION Conversion Kit for NG to LPG Model #516-969 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Burner Orifice Conversion Kit 516-969 Contains: Qty. Part # Description 1 904-390 Bu...
Page 14 - These instructions must be left with
14 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Installer Notice: These instructions must be left with the appliance. Minimum pressure: Remove one of the cables connected to the electric modulator. Keeping the nut (B) blocked, screw in the screw (C) to increase the pressure and screw ...
Page 15 - AERATION
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 15 INSTALLATION C)02-44 AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. NG: 10mm open LPG: 10mm open The aeration adjustment gears are located on the ...
Page 16 - DOOR INSTALLATION
16 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater Diagram 2 Diagram 3 4) The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by loosening the locking nut and turning the latch catch. See diagram 3. 5) Remove the blu...
Page 17 - LOUVRE
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 17 INSTALLATION LOUVRE INSTALLATION Attach the top & bottom louvres to the side stove panel using 2 screws per side. GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual ma...
Page 18 - FINAL CHECK; WIRING; CAUTION: Label all wires prior to; Caution: Ensure that the wires do; OPTIONAL
18 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly. This includes: 1) Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) at 15 minutes. 2...
Page 19 - OPERATING INSTRUCTIONS
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 19 OPERATING INSTRUCTIONS FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time yo...
Page 21 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 21 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. FOR YOUR SAFETY READ BEFORE LIGHTING A ) BEFORE LIGHTING smell all around the appliance a...
Page 22 - MAINTENANCE
22 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE. CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLI- ANCE. DO NOT USE ...
Page 23 - LATCH ADJUSTMENT; LOG REPLACEMENT
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 23 LATCH ADJUSTMENT The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the handle on the adjustable catch to tighten or loosen the latch. Installing Glass 1) Inst...
Page 24 - FAN MAINTENANCE
24 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace- ment it must be performed by an authorised person. Access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated witho...
Page 25 - REMOVING VALVE TRAY
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 25 MAINTENANCE 4) Remove the two outside frame pieces by removing two screws per side. See dia- gram below. REMOVING VALVE TRAY If your valve requires maintenance or replace- ment, follow these instructions: NOTE: Always shut off the gas an...
Page 26 - PARTS LIST; ELECTRONIC COMPONENTS PARTS LIST
26 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater FG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131 910-915 910-082 910-088 910-089 910-084 910-526 910-080 910-521, 910-522, 910-523 910-909 Fan Resistor 910-915 Intermittent Pilot 910-082 Direct Spark Ignitor 910-089 Flame Cable 910-088 Spark Ca...
Page 27 - FG37 MAIN ASSEMBLY
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 27 PARTS LIST 1) 560-920 Louvre Assy (Set) - Gold 560-922 Louvre Assy (Set) - Black 4) 730-038 Door Screen (Australia Only) 8) 730-560 Relief Door Assembly 10) 640-034 Mounting Plate Gasket 560-519/P Fan Assembly (240 V) 11) 910-169/P Fan M...
Page 28 - FG37 BURNER & LOG ASSEMBLY
28 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater FG37 BURNER & LOG ASSEMBLY 52) 910-190 Piezo Ignitor & Nut 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 918-088 Decal - Control Panel 57) 591-041 Switch Plate 680-574/P Valve Assembly - NG 680-576...
Page 29 - FG37 DOOR ASSEMBLIES
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 29 FG37 DOOR ASSEMBLIES Part # Description PARTS LIST 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic ...
Page 30 - NOTES
30 FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater _____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________...
Page 31 - WARRANTY
FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater 31 WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or spillage caused...
Page 32 - Printed in Canada
Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.