Page 2 - Room Sealed Gas Stove by FPI Fireplace Products; UNIT SPECIFICATIONS
2 Regency ® F39 Room Sealed Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency ® Room Sealed Gas Stove by FPI Fireplace Products International Ltd. The Regency ® Gas Series of hand crafted appliances has been designed to provide you with all the...
Page 3 - TABLE OF CONTENTS
Regency ® F39 Room Sealed Freestanding Gas Stove 3 TABLE OF CONTENTS OPERATING INSTRUCTIONS Operating Instructions ................................................ 22Lighting Instructions .................................................... 22Shutdown Instructions ......................................
Page 4 - SAFETY LABEL
4 Regency ® F39 Room Sealed Freestanding Gas Stove SAFETY LABEL This is a copy of the label that accompanies each REGENCY F39 Room Sealed Freestanding Gas Stove. We have printed a copy of the contents here for your review. The data plat is located on the inside of the drop down pedestal door. NOTE: ...
Page 5 - IMPORTANT; SAVE THESE; SPECIFICATIONS; INSTALLATION; GENERAL SAFETY
Regency ® F39 Room Sealed Freestanding Gas Stove 5 IMPORTANT SAVE THESE INSTRUCTIONS The REGENCY Room Sealed Freestanding Gas Stove must be installed in accordance AG601 and NZS 5261 and with these instruc-tions. Carefully read all the instructions in this manual fi rst. Consult the building authorit...
Page 8 - EXTERIOR FLUE TERMINATION LOCATIONS; Minimum clearances required for balanced fl ue terminals or
8 Regency ® F39 Room Sealed Freestanding Gas Stove INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals of outdoor appliances according to AG 601 (AGA gas installation code) or NZS 5261 (New Zealand) Minimum Clearance (mm) a B...
Page 9 - FLUING ARRANGEMENTS
Regency ® F39 Room Sealed Freestanding Gas Stove 9 INSTALLATION FLUING ARRANGEMENTS Vertical Terminations Using Dura-Flue Fluing System for Residential Manufactured and Mobile Homes The shaded area in the diagram below shows all allowable combi-nations of straight vertical and offset to vertical run...
Page 10 - DV STOVE HORIZONTAL FLUE KIT
10 Regency ® F39 Room Sealed Freestanding Gas Stove INSTALLATION DV STOVE HORIZONTAL FLUE KIT (# 946-112) INSTALLATION Minimum Installation Height: F39: 59-3/4" ( 1518mm) Review the following sequence of instructions which are typical of most installations. The sequence may vary depending on wal...
Page 12 - TERMINATION KIT; Planning Your Dura-Flue; COMPONENTS
12 Regency ® F39 Room Sealed Freestanding Gas Stove Pipe Length Round Support Box/Wall Thimble (Part # 940) Round Support Box/ Wall Thimble (Part # 940) Vertical Terminal Storm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" (610mm) Pipe Length Adj.Pipe Length 11" - ...
Page 13 - HORIZONTAL
Regency ® F39 Room Sealed Freestanding Gas Stove 13 Diagram 5 Note: If installing termination on a siding covered wall, a vinyl siding standoff or fur-ring strips must be used to ensure that the termination is not recessed into the siding. The four wood screws provided should be replaced with approp...
Page 14 - TERMINATION
14 Regency ® F39 Room Sealed Freestanding Gas Stove Diagram 11: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed. This allows for small adjustments. 4) Assemble the desired lengths of black pipe and elbows necessary to reach fr...
Page 15 - GAS CONNECTION; GAS PIPE PRESSURE; Offset Chart; CATHEDRAL CEILINGS; Support Extensions - Round
Regency ® F39 Room Sealed Freestanding Gas Stove 15 GAS CONNECTION The gas connection is a 3/8" NPT 90 o elbow. The gas line can be rigid pipe or to make in-stallation easier, use a listed fl exible connector and/or copper tubing if allowed by local codes. Since some municipalities have additiona...
Page 16 - System Data; Valve Description; AERATION
16 Regency ® F39 Room Sealed Freestanding Gas Stove Burner Inlet Orifi ce Sizes: NG LPG Burner #32 #50 2.95mm 1.78mm Max. Input NG 40 Mj/h LPG 38 Mj/h Min. Input NG 20 Mj/h LPG 19 Mj/h Supply Pressure NG min. 1.13 kPa LPG min. 2.75 kPa Manifold Pressure NG .94 kPa LPG 2.55kPa Electrical: 240 V. 1.13A...
Page 17 - Do not over tighten the screw.; Also check that the pilot and main
Regency ® F39 Room Sealed Freestanding Gas Stove 17 INSTALLATION CONVERSION KIT #731-968 FROM NG TO LPG THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! WARNING! Do not over tighten the screw. Recommended to grip the wrench by the short side. 1) Shut ...
Page 18 - LOG SET; CONVERSION TO LOWER BTU RATING; THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS
18 Regency ® F39 Room Sealed Freestanding Gas Stove LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit contains the following: a) 02-...
Page 21 - WIRING; WARNING: Electrical Grounding Instructions
Regency ® F39 Room Sealed Freestanding Gas Stove 21 WIRING CAUTION: Label all wires prior to dis-connection when servicing controls. Wiring errors can cause improper and dangerous operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug f...
Page 22 - OPERATING INSTRUCTIONS; HOT
22 Regency ® F39 Room Sealed Freestanding Gas Stove ADJUSTING FLAME HEIGHT Your heater has an adjustable fl ame to tailor the look and heat output to your specifi c needs. It is adjusted by turning the fl ame adjustment dial on the gas control valve. Turn clockwise to adjust the fl ame higher, countercl...
Page 23 - NORMAL; COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency ® F39 Room Sealed Freestanding Gas Stove 23 NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are ...
Page 24 - MAINTENANCE; GENERAL FLUE
24 Regency ® F39 Room Sealed Freestanding Gas Stove MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs,...
Page 25 - Mitred Glass Replacement; Panel Glass Replacement; LOG REPLACEMENT; DOOR GASKET
Regency ® F39 Room Sealed Freestanding Gas Stove 25 Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath t...
Page 26 - FAN MAINTENANCE; Electrical Grounding Instruc-
26 Regency ® F39 Room Sealed Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly se...
Page 27 - REMOVING VALVE
Regency ® F39 Room Sealed Freestanding Gas Stove 27 REMOVING VALVE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up. See diagram below. 4) Remove t...
Page 28 - PARTS LIST; F39 MAIN ASSEMBLY
28 Regency ® F39 Room Sealed Freestanding Gas Stove PARTS LIST 31) 630-021 Fan Access Panel 32) 730-028 Firebox Baffl e 33) 630-520 False Top Assembly 36) 936-194 Gasket - Starter Collar/ Air Passage 37) 936-197 Gasket - Flue Collar/ Starter Collar 38) 820-058 Pedestal Base Cover 39) 730-036 Gasket -...
Page 29 - F39 BURNER & LOG ASSEMBLY
Regency ® F39 Room Sealed Freestanding Gas Stove 29 F39 BURNER & LOG ASSEMBLY 52) 910-190 Piezo Ignitor & Nut 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 918-088 Control Plate Decal 57) * Switch Plate 730-574/P Valve Assembly - NG 60) 910-378 Valve - S.I.T. ...
Page 30 - F39 DOOR ASSEMBLIES
30 Regency ® F39 Room Sealed Freestanding Gas Stove PARTS LIST F39 DOOR ASSEMBLIES Part # Description 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic Paper 106) 9...
Page 31 - WARRANTY; Transportation Prepaid
Regency ® F39 Room Sealed Freestanding Gas Stove 31 WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over-fi ring, downdrafts or spillage caused by environm...