Page 3 - TABLE OF CONTENTS
Regency F38-2 Freestanding Gas Heater 3 TABLE OF CONTENTS SAFETY LABEL Safety Label................................................................... 5 INSTALLATION General Information ....................................................... 5Important ..................................................
Page 4 - SAFETY LABEL; Gas Type; Manifold Pressure; Model; Regency Gas Fireplace
4 Regency F38-2 Freestanding Gas Stove This is a copy of the label that accompanies each Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door. NOTE: Regency units are constantly being improved. C...
Page 5 - INSTALLATION
Regency F38-2 Freestanding Gas Heater 5 INSTALLATION GENERAL SAFETY INFORMATION 1) The appliance shall be installed in accord- ance with the manufacturer's installation instructions, local gas fi tting regulations, municipal building codes, water supply regulations, electrical wiring regulations, wi...
Page 6 - Clearances; Reference Dimensions
6 Regency F38-2 Freestanding Gas Stove INSTALLATION CLEARANCES TO COMBUSTIBLES The clearances listed below are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. (The farthest distance is correct if the two clear-ances do not coincide.) For example, if the appl...
Page 7 - Flueing Requirements; GAS CONNECTION; System Data
Regency F38-2 Freestanding Gas Heater 7 INSTALLATION Flueing Requirements A100 mm diameter fl ue is required. For cosmetic or aesthetic purposes 6" outer fl ue can be used as long as an approved inner fl ue is installed. Fasten but do not penetrate the inner sleeve of the fl ue when tightening t...
Page 9 - AERATION; LOG SET
Regency F38-2 Freestanding Gas Heater 9 INSTALLATION AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. F38-2 with 38 mj F38-NG2 NG: Full open F38-LPG2 LPG: 6.4 mm open Caution: Carbon will be produced if the air shutter is c...
Page 11 - FRONT DOOR
Regency F38-2 Freestanding Gas Heater 11 Note: If the fl ue is blocked or has a strong reverse fl ow, the thermally actuated safety switch mounted in the draft diverter will automatically shut off the gas supply within about 10 minutes. If the heater turns off be-cause of this during the spillage te...
Page 12 - CAUTION; OPTIONAL WALL
12 Regency F38-2 Freestanding Gas Stove OPTIONAL REMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on ...
Page 13 - WIRING; Label all wires prior to disconnection
Regency F38-2 Freestanding Gas Heater 13 WIRING CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your prot...
Page 14 - OPERATING INSTRUCTIONS; WARNING
14 Regency F38-2 Freestanding Gas Stove OPERATING INSTRUCTIONS 4) Turn the PILOT knob counterclockwise to pilot and align it with the arrow as shown in diagram 1. 5) Push in PILOT knob all the way in and hold. Immediately push IGNITOR button until pilot lights. Continue to hold the PILOT knob in for...
Page 15 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT SPRAY AEROSOLS IN THE VICINITY OF; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency F38-2 Freestanding Gas Heater 15 COPY OF THE LIGHTING PLATE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. OPERATING INSTRUCTIONS 1) Push in the gas control knob slightly and turn clockwise to OFF. Do not force. FOR YOUR SAFETY READ BEFORE...
Page 16 - NORMAL OPERATING; PILOT ADJUSTMENT
16 Regency F38-2 Freestanding Gas Stove NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some example...
Page 17 - MAINTENANCE
Regency F38-2 Freestanding Gas Heater 17 MAINTENANCE CLOTHING OR OTHER FLAMMA-BLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE AP-PLIANCE. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZED SERVICE TECHNI-CIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART O...
Page 18 - FAN MAINTENANCE; IMPORTANT; Disconnect power supply
18 Regency F38-2 Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the access panel on the rear wall of the fi rebox. If the unit is damaged or needs repair, it shall be repaired by the manufacturer or its service agent o...
Page 19 - REMOVING VALVE
Regency F38-2 Freestanding Gas Heater 19 4) Remove the two outside frame pieces by removing two screws per side. See diagram below. REMOVING VALVE If your valve requires maintenance or replace-ment, follow these instructions: NOTE: Always shut off the gas supply before removing the valve. 1) Open fr...
Page 20 - PARTS LIST; MAIN ASSEMBLY
20 Regency F38-2 Freestanding Gas Stove PARTS LIST MAIN ASSEMBLY 1) 560-920 Top/Bottom Gold Louvre (Set) 560-922 Top/Bottom Black Louvre (Set) 2) 750-532 Safety Screen (Australia only) 9) 750-040 Fan Access Door 10) 730-034 Gasket for Fan Access Door 560-519 Fan Assembly 11) 910-169/P Fan Motor (240...
Page 21 - BURNER & LOG ASSEMBLY
Regency F38-2 Freestanding Gas Heater 21 BURNER & LOG ASSEMBLY Part # Description PARTS LIST 52) 910-190 Piezo Ignitor & Nut 54) 910-373 Knob - S.I.T. Valve Extension 55) 910-372 Flame Adjusting Knob 56) 918-088 Control Panel Decal 57) * Control Panel Plate 750-527/P Valve Assembly - NG 750-...
Page 22 - DOOR ASSEMBLY
22 Regency F38-2 Freestanding Gas Stove 101 111 107 208 111 105 WRAP DOOR DOOR ASSEMBLY 730-933 Black Wrap Door - Complete 101) 846-570 Door Gasket Kit 105) * Ceramic Paper 107) 936-243 Glass Gasket 111) * Door Frame Fibre Paper 208) 940-325/P Wrap Glass *Not available as a replacement part. Part # ...
Page 23 - WARRANTY; Transportation Prepaid
Regency F38-2 Freestanding Gas Heater 23 WARRANTY Exclusions: This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over-fi ring, downdrafts or spillage caused by environmental cond...