Page 2 - Thank-you for purchasing a; REGENCY FIREPLACE PRODUCT.; Keep those; REGENCY FIRES
Regency Freestanding Woodstove 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the ...
Page 3 - TABLE OF CONTENTS; THE REGENCY FREESTANDING WOOD STOVE; OPERATING; MAINTENANCE; SAFETY LABEL; INSTALLATION
Regency Freestanding Woodstove 3 TABLE OF CONTENTS THE REGENCY FREESTANDING WOOD STOVE Optional Accessories Installation - Pedestal Ash Drawer Kit ............................................16 - Bottom Shield Ashdrawer Kit .....................................16 - Screen Door .........................
Page 5 - UNIT DIMENSIONS
Regency Freestanding Woodstove 5 UNIT DIMENSIONS 24” (610mm) 30-3/8" (772mm) 29-1/8" (740mm) 27-3/8” (695mm) 24-7/8” (632mm) 6-5/8” (168mm)
Page 6 - RESIDENTIAL; MODULAR INSTALLATION OPTIONS; Airmate OR
Regency Freestanding Woodstove 6 INSTALLATION RESIDENTIAL INSTALLATION 1) Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override so...
Page 7 - Residential Installation Clearances to Combustible Walls; Acorn; AUSTRALIA ONLY; IMPORTANT
Regency Freestanding Woodstove 7 AUSTRALIA ONLY MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat defl ector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to...
Page 8 - Minimum Alcove Clearance to Combustible Materials
Regency Freestanding Woodstove 8 Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" (2134mm) Maximum depth of alcove ...
Page 9 - STOVE ASSEMBLY; Airmate Assembly
Regency Freestanding Woodstove 9 INSTALLATION Diagram 4 Diagram 2 Diagram 3 STOVE ASSEMBLY PRIOR TO INSTALLATION All units require either the pedestal or 4 legs at-tached to the base. The F2402M stove requires either the Airmate or Rear Heat Defl ector on top of the stove. Clearances to combustible m...
Page 10 - CHIMNEY AND; Leg and Bottom Shield Assembly
Regency Freestanding Woodstove 10 Horizontal Installation Standard Ceiling Installation 8) To complete your chimney installation, install the double wall connector pipe from the stove’s fl ue collar to the chimney support device. 9) If you are using a horizontal connector, the chimney connector shoul...
Page 12 - COMBUSTIBLE WALL CHIMNEY
Regency Freestanding Woodstove 12 Method A : 12" (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C315 (Standard Specifi ...
Page 13 - RECOMMENDED HEIGHTS FOR; TABLE 1; 2 x 15
Regency Freestanding Woodstove 13 RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft. See Table 1. 1) At sea level minimum height is 12' (3.7m) straight. 2) Add the following vertical height to compen- sate for: 45 deg. elbow = 1 ft. (.3m) 90 deg. elbow = 2 ft. (.6m) "T" = 3 ft. (....
Page 14 - MOBILE HOME INSTALLATION
Regency Freestanding Woodstove 14 MOBILE HOME INSTALLATION Once you have properly marked the position of your unit and the fl oor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole throu...
Page 15 - Canadian Installations*; SECONDARY AIR TUBE; Freestanding Stove; LISTED COMPONENTS
Regency Freestanding Woodstove 15 side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side until it locks into position. If the tube will not slide in easily, simply use a pair of vise grips...
Page 16 - Pedestal Ash Drawer Kit; Bottom Shield Ash Drawer Kit
Regency Freestanding Woodstove 16 INSTALLATION GLASS INSTALLATION Remove the door from the stove and remove the glass retainer. Position the glass in the door, make sure that the glass gasketing will prop-erly seal your unit, and replace the retainer, it should rest on the gasket not the glass. Tigh...
Page 17 - WARNING: Electrical Grounding Instructions
Regency Freestanding Woodstove 17 Blower/Fan 1) Remove the two screws from the top of the fan housing. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the two screws removed earlier. CAUTION: The connection cord should not be in co...
Page 18 - OPERATING INSTRUCTIONS; DRAFT CONTROL; WARNING; FIRST FIRE
Regency Freestanding Woodstove 18 OPERATING INSTRUCTIONS 9) During the fi rst few days it may be more diffi cult to start the fi re. As you dry out your fi rebrick and your masonry fl ue, your draft will increase. 10) For those units installed at higher elevations or into sub-standard masonry fi replaces,...
Page 19 - SAFETY GUIDELINES; Safety Precautions; FAN OPERATION
Regency Freestanding Woodstove 19 OPERATING INSTRUCTIONS SAFETY GUIDELINES AND WARNINGS 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater. Keep all such liquids well away from the heater while it is ...
Page 20 - Ways to Prevent and Keep Unit
Regency Freestanding Woodstove 20 MAINTENANCE CREOSOTE When wood is burned slowly, it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosote residue accu...
Page 21 - STOVE MAIN ASSEMBLY; PARTS LIST
Regency Freestanding Woodstove 21 1) 846-913 Door Assy-Med Gold F2402M (no glass) 846-915 Door Assy-Med Black F2402M (no glass) 3) 846-302 Glass - Replacement - F2402M 4) 936-243 7/8" Adhesive Tape Gasket 5) 820-184 Glass Retainer Clips (8/set) 6) * Screw - 1/4 - 20 x 3/8" 7) 948-170/P Small...
Page 23 - FIREBRICK
Regency Freestanding Woodstove 23 70) 902-111 Brick - Regular Full Size: 1-1/4" x 4-1/2" x 9" 74) 802-147 Brick Partial: 1-1/4" x 4-1/2" x 3-1/2" 75) 802-122 Brick Partial: 1-1/4" x 4-1/2" x 2" 76) 802-152 Brick Partial: 1-1/4" x 2" x 9" Part # Descrip...
Page 24 - NOTES
Page 27 - WARRANTY
Regency Freestanding Woodstove 27 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to exte...
Page 28 - Printed in Canada
Printed in Canada © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved. DISTRIBUTORS: Western Australia Eastern Australia AUSTRALIAN HEATING DISTRIBUTORS FIREPLACE PRODUCTS AUSTRALIA PTY. LTD. 31 CLUNE STREET 21-23 SOUTH LINK BLVD. BAYSWATER, WA 6053 DANDENONG, VIC 3175 SE...