Page 2 - FPI GAS FIREPLACE INSERT; TO THE NEW OWNER; The E33 Sunrise
Regency ® E33S-1 Sunrise Gas Insert 2 FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI. The E33 Sunrise TM Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The E33...
Page 3 - TABLE OF CONTENTS
Regency ® E33S-1 Sunrise Gas Insert 3 TABLE OF CONTENTS SAFETY LABEL Copy of the Safety Label ............................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 UNIT DIMENSIONS Unit Dimensions .........................................
Page 4 - INST; SAFETY LABEL
Regency ® E33S-1 Sunrise Gas Insert 4 INST ALLA TION SAFETY LABEL This is a copy of the safety label that accompanies the E33 Sunrise TM Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® E33S-1 Sunrise Gas Insert 5 INST ALLA TION REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in wh...
Page 6 - UNIT DIMENSIONS
Regency ® E33S-1 Sunrise Gas Insert 6 INST ALLA TION UNIT DIMENSIONS
Page 7 - INSTALLATION; General Safety Information
Regency ® E33S-1 Sunrise Gas Insert 7 INST ALLA TION INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accord-ance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to de...
Page 8 - Electrical Grounding Instructions
Regency ® E33S-1 Sunrise Gas Insert 8 INST ALLA TION INSTALLATION 11) Due to high temperatures, the appliance should be located out of high traf fi c areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fi repl...
Page 9 - MINIMUM CLEARANCES TO COMBUSTIBLES; COMBUSTIBLE MANTEL CLEARANCES
Regency ® E33S-1 Sunrise Gas Insert 9 INST ALLA TION INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls A* 8" (203 mm) Ceiling B 47" (1194 mm) Min. Mantel Height C 15" (381 mm) Max. Mantel Depth D 3-1/2" (89 mm) Alcove Width E 76" (1930 mm) Alcove Depth F 36"...
Page 10 - VENTING; GAS CONNECTION; GAS CONNECTION WARNING:; FLUE LINER
Regency ® E33S-1 Sunrise Gas Insert 10 INST ALLA TION INSTALLATION VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the ch...
Page 11 - GAS PIPE; GAS INSERT; SIT VALVE DESCRIPTION
Regency ® E33S-1 Sunrise Gas Insert 11 INST ALLA TION INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less...
Page 15 - WIRING DIAGRAMS; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
Regency ® E33S-1 Sunrise Gas Insert 15 INST ALLA TION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. However, a 120V A.C. power supply is needed for the fan/blower operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (g...
Page 16 - PROPANE; Units and Units Equipped with DC Spark Boxes*; OPTIONAL WALL
Regency ® E33S-1 Sunrise Gas Insert 16 INST ALLA TION Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate. 1) Choose a convenient location on the wall to in...
Page 17 - GLASS DOOR INSTALLATION; GLASS CRYSTAL OR OPTIONAL CERAMIC STONES
Regency ® E33S-1 Sunrise Gas Insert 17 INST ALLA TION GLASS DOOR INSTALLATION INSTALLATION To install the glass door, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (see Diagrams 1 and 2). Be careful that the glass gasket does not roll up; there must b...
Page 18 - CONTEMPORARY FACEPLATE &
Regency ® E33S-1 Sunrise Gas Insert 18 INST ALLA TION INSTALLATION CONTEMPORARY FACEPLATE & DOOR FRAME INSTALLATION 1) Bring the faceplate up in front of the unit and connect the red & black ON/OFF wires from the unit to the ON/OFF switch on the back of the left side of the faceplate. 2) Con...
Page 20 - OPTIONAL HEARTH TRIM
Regency ® E33S-1 Sunrise Gas Insert 20 INST ALLA TION OPTIONAL HEARTH TRIM INSTALLATION The Hearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace. The faceplate is assembled fi rst and then the...
Page 21 - OPERATING INSTRUCTIONS; CAUTION; IMPORTANT
Regency ® E33S-1 Sunrise Gas Insert 21 OPERA TION OPERATING INSTRUCTIONS IMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed. 1) Turn burner OFF using "ON/OFF" switch. 2) Turn gas control knob so indicator points to "OFF"...
Page 23 - MAINTENANCE; GENERAL VENT; MAINTENANCE; Glass Replacement
Regency ® E33S-1 Sunrise Gas Insert 23 MAINTENANCE MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows: 1) Check the Venting System for corrosion in areas that are exposed to the elements. T h e s e w i l l a p p e a...
Page 24 - VALVE TRAY REPLACEMENT
Regency ® E33S-1 Sunrise Gas Insert 24 MAINTENANCE MAINTENANCE VALVE TRAY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 2) Disconnect the power source and turn off the gas supply to the insert. 3) Open the bottom louver. 4) Remove the door frame by lifting out from ...
Page 26 - FAN REPLACEMENT
Regency ® E33S-1 Sunrise Gas Insert 26 MAINTENANCE FAN REPLACEMENT 6) Remove the back shield by undoing the 2 screws shown. 9) Remove the base cover by lifting up from the back and maneover out. 7) Remove the burner by undoing the 2 screws shown. Carefully lift the burner up and out ensuring not to ...
Page 28 - ARTS LIST; PARTS LIST; MAIN ASSEMBLY
Regency ® E33S-1 Sunrise Gas Insert 28 P ARTS LIST PARTS LIST MAIN ASSEMBLY Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 120 V 5) 910-750 Power Cord 910-752 Wire Harness (Faceplate) * Wire Fan to Power Cord * ...
Page 29 - CONTEMPORARY FACEPLATE & DOOR FRAME
Regency ® E33S-1 Sunrise Gas Insert 29 P ARTS LIST PARTS LIST CONTEMPORARY FACEPLATE & DOOR FRAME Part # Description 341-914 Contemporary Faceplate & Door Frame 90) * Complete Faceplate 91) * Door Frame 92) * Bottom Louver 93) * Hinges 910-246 Burner ON/OFF Switch 910-330 Fan Speed Control 1...
Page 30 - NOTES
Page 31 - WARRANTY
Regency ® E33S-1 Sunrise Gas Insert 31 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is please...
Page 32 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...