Page 2 - FPI GAS FIREPLACE INSERT; TO THE NEW OWNER
2 E33 FPI Direct Vent Gas Insert FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI. The E33 Gas Insert has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The E33-NG and E33-LP hav...
Page 3 - TABLE OF CONTENTS; First Fire
3 E33 FPI Direct Vent Gas Insert TABLE OF CONTENTS FPI GAS FIREPLACE INSERT OPERATING INSTRUCTIONS First Fire ........................................................................ 18 Operating Instructions .......................................................... 18Lighting Procedure ..............
Page 4 - SAFETY LABEL
4 E33 FPI Direct Vent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened. Ensure that the saf...
Page 5 - INSTALLATION; General Safety Information
5 E33 FPI Direct Vent Gas Insert IMPORTANT: SAVE THESE INSTRUCTIONS The FPI Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdic-tion to determine the need for a permit prior to...
Page 6 - Electrical Grounding Instructions; If you are installing the Excali-
6 E33 FPI Direct Vent Gas Insert 14) Install optional Excalibur Surround. See page 15. 15) Install optional remote control or wall ther- mostat, pages 17. 16) Final check (page 18): Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This inc...
Page 7 - MINIMUM CLEARANCES TO COMBUSTIBLES; REGENCY FLUSH
7 E33 FPI Direct Vent Gas Insert MINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls * A 8" (203 mm) Ceiling B 47" (1194 mm) Min. Mantel Height C 15" (381 mm) Max. Mantel Depth D 3-1/2" (89 mm) Alcove Width E 76" (1930 mm) Alcove Depth F 36" (914 mm) Hearth Height G 1-1/4...
Page 8 - GAS CONNECTION WARNING:; FLUE LINER
8 E33 FPI Direct Vent Gas Insert VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. The fl ue length must be a mi...
Page 9 - SIT Valve Description
9 E33 FPI Direct Vent Gas Insert OPTIONAL BRICK PANEL Optional Brick Panel Set: Part # Description Qty Top (brick) panel 1 Back (brick) panel 1 Left (brick) panel 1 Right (brick)panel 1 340-043 Top bracket 1 340-094 Bottom clips 2 511-031 Brick clips 2 Diagram 1 GAS PIPE PRESSURE TESTING The applian...
Page 10 - LOG INSTALLATION
10 E33 FPI Direct Vent Gas Insert Top Bracket 5) Place the top bracket onto the top edge of the top panel (refer to Diagram 2). Diagram 2 6) Slide the top panel and bracket assembly carefully onto the baffl e plate ensuring the panel is centered. Make sure the tabs of the top bracket fi t into the baf...
Page 12 - E33 CONVERSION KIT FROM NG TO LPG; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
12 E33 FPI Direct Vent Gas Insert INSTALLATION Final Installation 03-19 E33 CONVERSION KIT FROM NG TO LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty. Part # Description 1 910-018 SIT Conversion Kit-50% Turndown LPG 1 9...
Page 13 - These instructions must be
13 E33 FPI Direct Vent Gas Insert Diagram 4 INSTALLATION 9) Attach the trim to the faceplate by using the plated screws (refer to Diagram 4). Rear View: Faceplate Assembly Diagram 1 FACEPLATE & TRIM INSTALLATION 1) Lay the faceplate panels fl at, face down on something soft so they don't scratch....
Page 14 - STANDARD; FLUSH LOUVERS; FULL SCREEN FRONT
14 E33 FPI Direct Vent Gas Insert INSTALLATION Diagram 5 11) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate. The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towa...
Page 15 - EXCALIBUR SURROUND; Bottom
15 E33 FPI Direct Vent Gas Insert 1) Align the left side Faceplate Trim Bracket with the Firebox Flange and secure using 2 screws as shown in diagram 1. Repeat for right side. Faceplate Trim Bracket Firebox Flange IMPORTANT NOTE: When using the Surround, the unit must be set 1" further into the ...
Page 16 - DOUBLE DOOR OPTION; ACCENT KIT
16 E33 FPI Direct Vent Gas Insert INSTALLATION 1) Remove the rivets from the surround by pulling off the hoseclamp (located at the backside of surround) with a screwdriver or plyer. Re-install the rivets by putting them through the holes on the sides of the sur-round. 3) Remove the handles by removi...
Page 17 - WIRING DIAGRAM; WARNING: Electrical Grounding Instructions; OPTIONAL REMOTE CONTROL
17 E33 FPI Direct Vent Gas Insert WIRING DIAGRAM INSTALLATION This heater does not require a 120V A.C. supply for operation. However, a 120V A.C. power sup-ply is needed for the fan/blower operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (groundin...
Page 18 - OPERATING INSTRUCTIONS; Thermostat Wire Table; CAUTION; results in damage to the exterior; IMPORTANT
18 E33 FPI Direct Vent Gas Insert OPERATING INSTRUCTIONS 2) Turn gas control knob so indicator points to "OFF" position and allow 5 minutes for any gas in the combustion chamber to escape. 3) Turn gas control knob counterclockwise so indicator points to the "PILOT" position. Depress ...
Page 20 - MAINTENANCE
20 E33 FPI Direct Vent Gas Insert MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows: 1) Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, ...
Page 21 - FAN MAINTENANCE; Flush Glass Replacement
21 E33 FPI Direct Vent Gas Insert MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replace-ment, access to the fan is through the plate on the fl oor of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place. Caution: Label all wires prior to di...
Page 22 - VALVE ASSEMBLY
22 E33 FPI Direct Vent Gas Insert MAINTENANCE 11) Disconnect the inlet gas line. 12) Unplug the black and red wires at the valve. Undo the 2 TP wires at the valve. 13) Remove the 17 screws on the valve tray. 14) Take out the valve tray from the unit. 15) Scrape off the old gasket from the fl oor of t...
Page 23 - PARTS LIST; MAIN ASSEMBLY
23 E33 FPI Direct Vent Gas Insert PARTS LIST MAIN ASSEMBLY Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-331/P Fan Motor 120 V 5) 910-750 Power Cord 910-752 Wire Harness (Faceplate) 910-692 Wire Fan to Power Cord 910-737 Wire ...
Page 24 - BURNER & LOG ASSEMBLY
24 E33 FPI Direct Vent Gas Insert PARTS LIST BURNER & LOG ASSEMBLY Part # Description 52) 340-104 Gasket - Valve Tray 340-574/P Valve Assembly - NG 340-576/P Valve Assembly - LP 56) 910-190 Piezo Ignitor and Nut 57) 910-378 Valve - S.I.T. - Natural Gas 910-380 Valve - S.I.T. - Propane 59) * Valv...
Page 25 - FULL SCREEN FRONT INSTALLATION
25 E33 FPI Direct Vent Gas Insert 83 84 85 86 87 88 88 88 88 89 90 90 FULL SCREEN FRONT INSTALLATION Part # Description PARTS LIST 83) Top Frame 84) 340-910 Full Screen Door - Black 85) Full Screen Left Door 86) Full Screen Right Door 87) Bottom Frame 88) Screw #8 x 1/2 Self Tapping 89) 910-199 Wire...
Page 26 - FACEPLATES, TRIMS AND HEARTHS
26 E33 FPI Direct Vent Gas Insert PARTS LIST FACEPLATES, TRIMS AND HEARTHS Part # Description Part # Description 340-918 Faceplates and Trim (Complete) with Black Trim 340-919 Oversized Faceplate 74) 904-569 Fan Speed Control Knob 91) * Faceplate Side - Right 92) * Faceplate - Top 93) * Faceplate Si...
Page 27 - NOTES
Page 31 - WARRANTY
31 E33 FPI Direct Vent Gas Insert WARRANTY FPI Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to exte...
Page 32 - Installer: Please complete the following information; Printed in Canada
32 E33 FPI Direct Vent Gas Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ ...