Page 2 - FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.; The Regency; has been designed to provide you with all the warmth and charm
2 Regency ® E21-3 Gas Fireplace Insert CONGRATULATIONS! You are the owner of a state-of-the-art Gas Insert by: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency ® Gas Fireplace Series has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The m...
Page 3 - TABLE OF CONTENTS
3 Regency ® E21-3 Gas Fireplace Insert TABLE OF CONTENTS SAFETY LABEL Serial No. Decal ........................................................... 4 REQUIREMENTS MA Code - CO Detector ................................................ 5 INSTALLATION Important Message .....................................
Page 4 - SAFETY LABEL
4 Regency ® E21-3 Gas Fireplace Insert SAFETY LABEL This is a copy of the label that accompanies each Regency ® Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit visible when the bottom louver is open. Note: Rege...
Page 5 - REQUIREMENTS; MA Code - CO Detector
5 Regency ® E21-3 Gas Fireplace Insert REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part...
Page 6 - INSTALLATION; cally approved
6 Regency ® E21-3 Gas Fireplace Insert IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Regency ® Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need f...
Page 8 - CLEARANCES TO COMBUSTIBLES
8 Regency ® E21-3 Gas Fireplace Insert CLEARANCES TO COMBUSTIBLES aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa INSTALLATION The minimum clearance from the side of the appliance to a combustible sid...
Page 9 - HIGH ELEVATION; System Data; GAS CONNECTION
9 Regency ® E21-3 Gas Fireplace Insert HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA 2.17-M91) with the ori fi ce supplied. System Data For altitude: Natural Gas 0-2000 ft. Propane: 0-4500 ft. Burner Inlet Ori fi ce Sizes: Natural Gas Propane Burner #43 #54 Max. ...
Page 10 - WIRING DIAGRAMS; WARNING: Electrical Grounding; Grounding; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
10 Regency ® E21-3 Gas Fireplace Insert WIRING DIAGRAMS INSTALLATION CAUTION: Label all wires prior to disconnection when servicing c o n t r o l s . W i r i n g e r r o r s c a n cause improper and dangerous operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a thr...
Page 11 - FLUE CONNECTOR INSTALLATION; PROPANE; Units and Units Equipped with DC Spark Boxes*
11 Regency ® E21-3 Gas Fireplace Insert Note: Do not operate unit if fl ue connector is not fastened in original position. FLUE CONNECTOR INSTALLATION 1) Remove the screw holding the fl ue connector plate to the appliance. 2) Slide the plate out and attach to the fl ue liner inside the fi replace to...
Page 14 - LOG SET INSTALLATION
14 Regency ® E21-3 Gas Fireplace Insert LOG SET INSTALLATION Log kit (Part # 533-930) contains the following pieces: a) 27-23 Back Center Log b) 27-24 Middle Center Log c) 27-25 Middle Right Log d) 27-26 Front Right Log e) 27-27 Center Front Log f) 27-28 Middle Left Log g) 27-29 Front Left Log h) 27...
Page 17 - Completed Log Set Installation
17 Regency ® E21-3 Gas Fireplace Insert Completed Log Set Installation 27-23 11) Place embers along the front of the burner as shown. Ensure not to cover any burner ports. 27-25 27-28 27-24 27-26 27-29 27-27 27-30 12) Place rock wool along side the embers on the front of the burner as shown. Ensure ...
Page 19 - FLUSH GLASS; The use of substitute glass will; ed; FLUSH LOUVERS
19 Regency ® E21-3 Gas Fireplace Insert FLUSH GLASS 1) Install the bottom glass trim onto the glass support. 2) Slide the glass into the bottom glass trim and secure with the glass clips using the 2 phillips head screws at the top. 3) Slide the top glass trim by sliding under the two spring clips. N...
Page 20 - BAY LOUVERS; OPTIONAL BAY FRONT; IMPORTANT
20 Regency ® E21-3 Gas Fireplace Insert BAY LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top. Diagram 1 NOTE: The top and bottom trim pieces are di...
Page 22 - Installation of the DC Sparker:
22 Regency ® E21-3 Gas Fireplace Insert 17) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5). 18) Re-assemble the black protection cap (Fig. 6). WARNING! Also check that the pilot and main burner injectors are appropriate for the ga...
Page 23 - These instructions must
23 Regency ® E21-3 Gas Fireplace Insert Installer Notice: These instructions must be left with the appliance. 37) Check for gas leaks. 38) Check inlet and outlet pressures. 39) Check operation of fl ame control. 40) Check for proper fl ame appearance and glow on logs. 29) Install the 1/2" bushin...
Page 24 - FULL SCREEN DOORS
24 Regency ® E21-3 Gas Fireplace Insert FULL SCREEN DOORS 1) Hold the full screen door up against the unit in order to make the following wire connections. Pull the ON/OFF connector wires thru the box and connect them to the switch. Connect the fan switch wires with the wire connectors from the fan ...
Page 26 - Thermostat Wire Table; WALL SWITCH; CAUTION; REMOTE CONTROL; CAUTION; WALL THERMOSTAT
26 Regency ® E21-3 Gas Fireplace Insert Thermostat Wire Table CAUTION Do not wire millivolt wall thermostat wires to 120V wire. WALL SWITCH 1) Run the wire through the right or left side inlet opening. Be careful not to damage the wire. Note: We recommend a maximum of 15' of wire but if you wish to ...
Page 27 - OPERATING INSTRUCTIONS
27 Regency ® E21-3 Gas Fireplace Insert FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes. 2) If required, adjustin...
Page 28 - COPY OF LIGHTING PLATE INSTRUCTIONS
28 Regency ® E21-3 Gas Fireplace Insert OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS LIGHTING INSTRUCTIONS TO TURN OFF GAS APPLIANCE Gas Inlet
Page 29 - MAINTENANCE
29 Regency ® E21-3 Gas Fireplace Insert MAINTENANCE INSTRUCTIONS 1) Always turn the gas valve to off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs, use a clean soft...
Page 30 - REMOVING THE FAN; DOOR GLASS; Bay Glass Removal; Flush Glass Replacement
30 Regency ® E21-3 Gas Fireplace Insert REMOVING VALVE ASSEMBLY 1) Disconnect the power. 2) Shut off the gas. 3) Remove top and bottom louvers. 4) Remove top and bottom trim. 5) Remove glass. 6) Remove log set & embers, and brick panels. 7) Disconnect the gas line. 8) Remove wires from valve (to...
Page 31 - PARTS LIST; MAIN ASSEMBLY
31 Regency ® E21-3 Gas Fireplace Insert PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 530-518/P Fan Assembly 1) 910-331/P Fan Motor (120V) 2) 910-750 Power Cord (120V) 910-752 Wire Harness (Intermediate) 3) * Firebox Bottom 4) 936-238 Soft Fiber Gasket 8mm 5) 936-233 3/4" Rope G...
Page 32 - BURNER ASSEMBLY & LOG SET
32 Regency ® E21-3 Gas Fireplace Insert BURNER ASSEMBLY & LOG SET Part # Description 533-574/P Valve Assembly- NG 533-576/P Valve Assembly - LPG 52) 910-468 Valve SIT - NG/LPG 53) 910-190 Piezo Ignitor & Nut 56) 910-076 Pilot Assembly - SIT - 3 fl ame -NG 910-077 Pilot Assembly - SIT - 3 fl ...
Page 33 - BAY & FLUSH FRONT ASSEMBLY
33 Regency ® E21-3 Gas Fireplace Insert PARTS LIST BAY & FLUSH FRONT ASSEMBLY Part # Description Part # Description Bay Door 530-950 Complete Bay Front c/w Black Trim 106) 940-312/P Side Glass 107) 936-243 Gasket - Adhesive Backed 7/8" 108) 940-313/P Center Glass 111) 400-153 Bay Glass Trim ...
Page 34 - FACEPLATE ASSEMBLY
34 Regency ® E21-3 Gas Fireplace Insert FACEPLATE ASSEMBLY Part # Description 91) 910-330 Fan Speed Control (120 V) 92) 904-569 Fan Speed Control Knob 93) 910-246 Burner Switch ON/OFF (2 way) 400-950 Hearth Trim 1" Standard 320-940 Hearth Trim 1" Oversize 400-926 Hearth Trim 2" Standard ...
Page 35 - WARRANTY
35 Regency ® E21-3 Gas Fireplace Insert WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleas...
Page 36 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...