Page 2 - Thank-you for purchasing a; REGENCY FIREPLACE PRODUCT.; Keep those; REGENCY FIRES
Regency CS1200 Wood Cast Insert 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the...
Page 3 - SAFETY LABEL
Regency CS1200 Freestanding Wood Stove 3 SAFETY LABEL This is a copy of the label that accompanies each CS1200 Wood Stove . We have printed a copy of the contents here for your review. HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ...
Page 4 - TABLE OF CONTENTS
4 Regency CS1200 Freestanding Wood Stove TABLE OF CONTENTS SAFETY LABEL Copy of the Safety Label ............................................... 3 DIMENSIONS Unit Dimensions ............................................................ 5 INSTALLATION Residential Installation.............................
Page 5 - DIMENSIONS; UNIT DIMENSIONS; CL
Regency CS1200 Freestanding Wood Stove 5 DIMENSIONS UNIT DIMENSIONS 9-15/16 ” 14-7/16 ” 39-9/16 ”( 1 1 0 5 m m ) 17-1/8” (436mm) 26-3/4”(680mm) A A 21-3/4” (552mm) 37-13/16” (961mm) 19-1/16” (485mm) (250mm) (367mm) 17-1/8” (436mm) 27-1/8” (689mm) 9-15/16” (250mm) 7-5/16” (186mm) 17-1/8” (435mm) CL f...
Page 6 - INSTALLATION; RESIDENTIAL; ROOM AIR
6 Regency CS1200 Freestanding Wood Stove INSTALLATION RESIDENTIAL INSTALLATION 1) Read all instructions before installing your Re-gency Stove. Install and use only in accordance with these installation and operating instructions. Be aware that local Codes and Regulations may override some items in t...
Page 7 - MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS; FROM THE REAR HEAT SHIELD TO A BACK WALL; Check with your local inspector.
Regency CS1200 Freestanding Wood Stove 7 INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND FROM THE REAR HEAT SHIELD TO A BACK WALL NOTE: Be aware that local Codes and Regulations may ove...
Page 8 - Floor Protection; USA; MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS
8 Regency CS1200 Freestanding Wood Stove INSTALLATION Z 6" 6" 16" Y Y X X 6" for angled corners 6" 16" 6" 6" Z The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcov...
Page 9 - STEP BY STEP
Regency CS1200 Freestanding Wood Stove 9 INSTALLATION Horizontal Installation Standard Ceiling Installation 8) To complete your chimney installation, install the double wall connector pipe from the stove’s fl ue collar to the chimney support device. 9) If you are using a horizontal connector, the ch...
Page 11 - COMBUSTIBLE WALL CHIMNEY
Regency CS1200 Freestanding Wood Stove 11 INSTALLATION Method A : 12" (304.8 mm) Clearance to Combustible Wall Member: Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall pass-through. The clay liner must conform to ASTM C...
Page 12 - MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET; RECOMMENDED; TABLE 1
12 Regency CS1200 Freestanding Wood Stove INSTALLATION MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) ABOVE SEA LEVEL 0 2 x 15 o 4 x 15 o 2 x 30 o 4 x 30 o 2 x 45 o 4 x 45 o 0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0 1000-2000 12.5 13.5 14.5 15...
Page 13 - MOBILE HOME INSTALLATION
Regency CS1200 Freestanding Wood Stove 13 INSTALLATION MOBILE HOME INSTALLATION WARNING: Minimum height requirements must be met. Safe removal of the chimney system must be adhered to when transporting the mobile home. WARNING: Operate only with door fully closed - open feed door to feed fi re only....
Page 14 - Canadian Installations*; LISTED COMPONENTS FOR
14 Regency CS1200 Freestanding Wood Stove INSTALLATION SIMPSON DURA-PLUSQty.Part # Description 1 6DVL8693 Connector Kit 1 6DP-MH9096 Mobile Home Kit ICC EXCEL 2100 Qty.Part # Description 1 6CL48 48" Chimney length (also in 12",18", 24" lengths. 1 6RC Rain Cap 1 6RCS Spark Screen (for...
Page 15 - BRICK INSTALLATION
Regency CS1200 Freestanding Wood Stove 15 INSTALLATION Side View Front View Front View 1) If the two air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air hol...
Page 16 - SIDE PANEL INSTALLATION; Stainless Steel Panels
16 Regency CS1200 Freestanding Wood Stove INSTALLATION SIDE PANEL INSTALLATION Before installation, panels must be handled and cleaned as per instructions noted below: Stainless Steel Panels • Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be record...
Page 17 - ASH DRAWER OPTION
Regency CS1200 Freestanding Wood Stove 17 INSTALLATION ASH DRAWER OPTION 2) Remove the bricks from the fl oor of the fi rebox. 5) Position ash drawer lid in 'Open' position on the ash drawer lid (towards the front) as shown below. 6) Slide in ash drawer. 7) Close center door and main top door- once ...
Page 18 - LOWER SURROUND DOOR REVERSAL
18 Regency CS1200 Freestanding Wood Stove INSTALLATION LOWER SURROUND DOOR REVERSAL (LEFT TO RIGHT SIDE OPENING) 1) The lower surround door can be reversed - to open from the right. Make sure stove has cooled, open the door - and remove it from the hinge by removing 2 bolts. 2) Remove and discard th...
Page 19 - CAST DOOR REVERSAL
Regency CS1200 Freestanding Wood Stove 19 INSTALLATION CAST DOOR REVERSAL (LEFT TO RIGHT SIDE OPENING) 1) The door can be reversed - so that it will open to the left. Make sure stove has cooled to room temperature. Open the door to about 45 ° - then remove it from the hinge by lifting up and out. No...
Page 20 - OPTIONAL ASHLIP INSTALLATION
20 Regency CS1200 Freestanding Wood Stove INSTALLATION OPTIONAL ASHLIP INSTALLATION WOOD STORAGE When storing wood within pedestal- ensure wood does not protrude past door opening. Do not store newspaper within pedestal.Note: Please refer to local codes. (B365, NFPA 211) and your local jurisdiction....
Page 21 - WARNING: Electrical Grounding Instructions; FAN OPERATION
Regency CS1200 Freestanding Wood Stove 21 INSTALLATION 1) Remove the fi ve screws from the back panel of the unit - to remove the fan cover plate. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the fi ve screws removed earlier. 4)...
Page 22 - OPERATING INSTRUCTIONS; WARNING; DRAFT CONTROL
22 Regency CS1200 Freestanding Wood Stove 22 OPERATING INSTRUCTIONS 8) Do not place anything on the stove top during the curing process. This may result in damage to your paint fi nish. 9) During the fi rst few days it may be more diffi cult to start the fi re. As you dry out your fi rebrick and you...
Page 23 - ASH DISPOSAL; Safety Precautions
Regency CS1200 Freestanding Wood Stove 23 OPERATING INSTRUCTIONS ASH DISPOSAL During constant use, ashes should be removed every few days. The Ash Drawer option features a convenient ash dump for easy removal of ash, refer to the "Modular Options" section. Safety Precautions 1) Do not allow ...
Page 24 - MAINTENANCE; SAFETY GUIDELINES AND; FAN MAINTENANCE
24 Regency CS1200 Freestanding Wood Stove MAINTENANCE SAFETY GUIDELINES AND WARNINGS 1) Never use gasoline, gasoline type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or ‘freshen up’ a fi re in your heater. Keep all such liquids well away from the heater while it is in...
Page 25 - Ways to Prevent and Keep Unit Free of
Regency CS1200 Freestanding Wood Stove 25 MAINTENANCE CREOSOTE When wood is burned slowly, it produces tar and other organic vapors, which when combined with moisture, form creosote. The creosote vapors condense in the relatively cool chimney fl ue of a slow burning fi re. As a result, creosote resi...
Page 26 - PARTS LIST; MAIN ASSEMBLY
26 Regency CS1200 Freestanding Wood Stove PARTS LIST 1 6 13 14 11 3 2 9 4 5 10 7 8 12 Part # Description 1) 076-201 Cast Stove Top 2) 076-211 Cast Pedestal 3) 156-211 Surround Bottom 4) 156-513 Curved Door Assembly 5) 156-261 Thin Surround 6) 076-921 Side Shield (Black Set) 076-927 Side Shield (Stai...
Page 27 - FAN ASSEMBLY
Regency CS1200 Freestanding Wood Stove 27 PARTS LIST Part # Description 200-917 Fan Assembly Package 1) 220-026 Fan Housing Front 2) 222-022 Fan Housing Bottom 3) 222-036 Sensor Mount 4) 200-227 Fan Bracket Right Hand 5) 200-228 Fan Bracket Left Hand 6) 200-229 Fan Housing Back 7) 910-157/P Fan 8) 9...
Page 28 - NOTES
Page 31 - WARRANTY
Regency CS1200 Freestanding Wood Stove 31 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased...
Page 32 - Installer: Please complete the following information; Printed in Canada
32 Regency CS1200 Freestanding Wood Stove 32 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: _________________________________________________...