Page 3 - TABLE OF CONTENTS
Regency ® CLASSIC C33-3 Freestanding Gas Stove 3 TABLE OF CONTENTS SAFETY LABEL Serial No. Decal ............................................................ 4 REQUIREMENTS MA Code - CO Detector(for state of Massachusetts only) .................................. 5 INSTALLATION Before You Start ........
Page 4 - SAFETY LABEL
4 Regency ® CLASSIC C33-3 Freestanding Gas Stove This is a copy of the label that accompanies each CLASSIC Freestanding Gas Stove - Natural Gas and Propane . We have printed a copy of the contents here for your review. The safety label is located on the back panel. NOTE: Regency ® units are constant...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® CLASSIC C33-3 Freestanding Gas Stove 5 REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole ...
Page 6 - INSTALLATION
6 Regency ® CLASSIC C33-3 Freestanding Gas Stove INSTALLATION IMPORTANT MESSAGE The CLASSIC Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the n...
Page 7 - OPTIONAL FAN; CLEARANCES TO
Regency ® CLASSIC C33-3 Freestanding Gas Stove 7 Diagram 4 9) Lift the fan assembly in through the pedestal and up through the cut out as shown in diagrams 3 and 4. 10) Put the insulation gasket on the back of the fan. Line up the keyhole slots with the matching screws and pull back slightly to lock...
Page 8 - PEDESTAL ASSEMBLY; Wiring
8 Regency ® CLASSIC C33-3 Freestanding Gas Stove INSTALLATION PEDESTAL ASSEMBLY 1) For easier assembly, tip the stove on its back (preferably onto a soft surface to prevent scratching). 2) Unscrew the 4 bolts in the underside of the stove. Align the holes in the corners of the pedestal top with the ...
Page 10 - Installing into Existing
10 Regency ® CLASSIC C33-3 Freestanding Gas Stove HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M90) with the orifi ce supplied. GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off ...
Page 12 - LOG SET; TEST FOR
12 Regency ® CLASSIC C33-3 Freestanding Gas Stove Diagram 2 LOG SET INSTALLATION WARNING: Dangerous operating condi-tions may occur if these logs are not po-sitioned in their approved locations. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit u...
Page 14 - WIRING DIAGRAMS; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
14 Regency ® CLASSIC C33-3 Freestanding Gas Stove WIRING DIAGRAMS This heater does not require a 120V A.C. sup-ply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan...
Page 15 - NORMAL OPERATING SOUNDS OF GAS APPLIANCES; PROPANE; Units and Units Equipped with DC Spark Boxes*
Regency ® CLASSIC C33-3 Freestanding Gas Stove 15 It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal op- erating so...
Page 16 - OPERATING INSTRUCTIONS
16 Regency ® CLASSIC C33-3 Freestanding Gas Stove OPERATING INSTRUCTIONS LIGHTING PROCEDURE NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc-tions" section for more details. IMPORTANT: Gas on/off knob cannot be turned from "PIL...
Page 17 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE; FOR YOUR SAFETY READ BEFORE LIGHTING; LIGHTING INSTRUCTIONS
Regency ® CLASSIC C33-3 Freestanding Gas Stove 17 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS 1) Push in gas control knob slightly and turn to “PILOT” position. 2) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for abou...
Page 18 - MAINTENANCE
18 Regency ® CLASSIC C33-3 Freestanding Gas Stove PILOT ADJUSTMENT Periodically check the pilot fl ames. Correct fl ame pattern has three strong blue fl ames: 1 fl owing around the thermopile, 1 around the thermocouple and 1 fl owing across the burner (it does not have to be touching the burner). Note: I...
Page 19 - GLASS; LOG REPLACEMENT
Regency ® CLASSIC C33-3 Freestanding Gas Stove 19 7) Install the replacement glass. When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. 8) Put glass in place and then position glass retainer rod. Note: Do not use substitute materials. If y...
Page 20 - REMOVING; INSTALLING
20 Regency ® CLASSIC C33-3 Freestanding Gas Stove MAINTENANCE 8) If optional fan is installed, remove thermodisc to bracket by removing three (3) phillips head M5 screws. 9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws. 10) Loosen four (4) phillips head M5 valve mount...
Page 21 - MAIN ASSEMBLY; PARTS LIST
Regency ® CLASSIC C33-3 Freestanding Gas Stove 21 MAIN ASSEMBLY PARTS LIST Part # Description 1) 850-141 Small Door - Black 850-142 Small Door - Gold 850-143 Small Door - Nickel Accent 850-144 Small Door - Gold Accent 850-151 Large Door - Black 850-152 Large Door - Gold 850-153 Large Door - Nickel A...
Page 23 - BASE OPTIONS
Regency ® CLASSIC C33-3 Freestanding Gas Stove 23 BASE OPTIONS PARTS LIST 490-921 Complete Floor Shield 100) 948-216 Regency ® Logo (Gold) 948-223 Regency ® Logo (Silver) 102) 904-257 Magnetic Catch (Large) 103) * 11" Pedestal Hinge 108) 910-246 Burner ON/OFF Switch (2-way) 109) 910-272 LT. Dumm...
Page 24 - NOTES
24 Regency ® CLASSIC C33-3 Freestanding Gas Stove ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ __________________________________________...
Page 27 - WARRANTY
Regency ® CLASSIC C33-3 Freestanding Gas Stove 27 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd...
Page 28 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...