Page 3 - TABLE OF CONTENTS
Regency CLASSIC C33-2 Freestanding Gas Stove 3 TABLE OF CONTENTS Safety Label Safety Label ............................................................. 4-5 Installation Before you start .......................................................... 6General Safety Information .............................
Page 4 - SAFETY LABEL; FPI Fireplace Products International Ltd.; DO NOT REMOVE THIS LABEL; Minimum Clearances to Combustibles
4 Regency CLASSIC C33-2 Freestanding Gas Stove This is a copy of the label that accompanieseach CLASSIC Freestanding Gas Stove - Nat-ural Gas. We have printed a copy of thecontents here for your review. The safety labelis located on the back panel. NOTE: Regency units are constantly beingimproved. C...
Page 6 - INSTALLATION
6 Regency CLASSIC C33-2 Freestanding Gas Stove INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The CLASSIC Freestanding Gas Stove must beinstalled in accordance with these instructions.Carefully read all the instructions in this manualfirst. Consult the "authority having jurisdiction"to dete...
Page 7 - OPTIONAL FAN; CLEARANCES TO
Regency CLASSIC C33-2 Freestanding Gas Stove 7 Diagram 4 9 ) Lift the fan assembly in through the pedes- tal and up through the cut out as shown indiagrams 3 and 4. 10) Put the insulation gasket on the back of the fan. Line up the keyhole slots with thematching screws and pull back slightly tolock i...
Page 8 - PEDESTAL ASSEMBLY; Wiring; Caution: Ensure that wires do
8 Regency CLASSIC C33-2 Freestanding Gas Stove INSTALLATION PEDESTAL ASSEMBLY 1 ) For easier assembly, tip the stove on its back (preferably onto a soft surface toprevent scratching). 2 ) Unscrew the 4 bolts in the underside of the stove. Align the holes in the corners of thepedestal top with the co...
Page 10 - Installing into Existing
10 Regency CLASSIC C33-2 Freestanding Gas Stove HIGH ELEVATION This unit is approved in Canada for altitude 0 to4500 ft. (CAN1 2.17-M90) with the orifice sup-plied. GAS PIPE PRESSURE TESTING The appliance must be isolated from the gassupply piping system by closing its individualmanual shut-off valv...
Page 11 - LOG SET; TEST FOR FLUE; Valve Description
Regency CLASSIC C33-2 Freestanding Gas Stove 11 Diagram 2 LOG SET INSTALLATION WARNING: Dangerous operatingconditions may occur if these logsare not positioned in their approvedlocations. Read the instructionsbelow carefully and refer to thediagrams. If logs are broken do notuse the unit until they ...
Page 13 - NORMAL OPERATING SOUNDS OF GAS APPLIANCES
Regency CLASSIC C33-2 Freestanding Gas Stove 13 INSTALLATION It is possible that you will hear some soundsfrom your gas appliance. This is perfectlynormal due to the fact that there are variousgauges and types of steel used within yourappliance. Listed below are some examples.All are normal operatin...
Page 14 - OPERATING INSTRUCTIONS
14 Regency CLASSIC C33-2 Freestanding Gas Stove OPERATING INSTRUCTIONS LIGHTING PROCEDURE IMPORTANT: Gas cock knob cannot beturned from "PILOT" to "OFF" unless it ispartially depressed. 1 ) Turn burner OFF using "ON/OFF" switch. 2 ) Turn gas control knob so indicator points t...
Page 15 - COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency CLASSIC C33-2 Freestanding Gas Stove 15 COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS 1) Push in the gas control knob slightly and turn clockwise to “OFF”. Do not force. FOR YOUR SAFETY READ BEFORE LIGHTING A ) This appliance has a pilot which must be lighted by hand, follow...
Page 16 - MAINTENANCE
16 Regency CLASSIC C33-2 Freestanding Gas Stove PILOT ADJUSTMENT Periodically check the pilot flames. Cor-rect flame pattern has three strong blueflames: 1 flowing around the thermopile,1 around the thermocouple and 1 flowingacross the burner (it does not have to betouching the burner). Note: If you...
Page 17 - GLASS; LOG REPLACEMENT
Regency CLASSIC C33-2 Freestanding Gas Stove 17 7 ) Install the replacement glass. When placing the replacement glass in the door, makesure that the glass gasketing will properlyseal your unit. 8 ) Put glass in place and then position glass retainer rod. Note: Do not use substitute materials. If you...
Page 18 - REMOVING VALVE; INSTALLING VALVE
18 Regency CLASSIC C33-2 Freestanding Gas Stove MAINTENANCE 8 ) If optional fan is installed, remove thermo- disc to bracket by removing three (3) phillipshead M5 screws. 9 ) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws. 10) Loosen four (4) phillips head M5 valve moun...
Page 19 - MAIN ASSEMBLY; PARTS LIST
Regency CLASSIC C33-2 Freestanding Gas Stove 19 MAIN ASSEMBLY PARTS LIST Part # Description 1 ) 846-913 Door Assy-Gold (no glass) 846-915 Door Assy-Black (no glass) 3 ) 846-302 Small Glass 4 ) 936-243 Glass Gasket (7/8") 5 ) 846-920 Glass Retainer Clips (8/set) 6 ) * Screw 1/4 - 20 x 3/8" 7 ...
Page 21 - BASE OPTIONS
Regency CLASSIC C33-2 Freestanding Gas Stove 21 BASE OPTIONS PARTS LIST 490-921 Complete Floor Shield 100) 948-216 Regency Logo 102) 904-257 Magnetic Catch (Large) 103) * 11" Pedestal Hinge 108) 910-246 Burner ON/OFF Switch (2-way) 109) 910-272 LT. Dummy Plug 110) * Strain Relief for power cord ...
Page 22 - NOTES
22 Regency CLASSIC C33-2 Freestanding Gas Stove _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ______________________________________________...
Page 23 - WARRANTY
Regency CLASSIC C33-2 Freestanding Gas Stove 23 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects eachunit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. i...
Page 24 - Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: __________________________...