Page 2 - PRODUCT SAFETY SIGNS AND LABELS; An example of a heat pump safety label follows.; AUDIENCE; The audience for this manual is twofold:; WARRANTY CLAIMS; CAUTION
i PRODUCT SAFETY SIGNS AND LABELS This manual, as well as the pool/spa heat pump itself, contains ANSI-approved product safety signs and labels. Please read these signs and labels, as they convey important safety information about hazards that may be potentially present in and around the heat pump. ...
Page 3 - ii; Swimming Pool Heat Pump; CONTENTS
ii Swimming Pool Heat Pump OWNER’S MANUAL - Models 5100 and 6100 CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Installation Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - base should be at least 3 ft by 3 ft.; WARNING
1 Introduction This pool heat pump is an electromechanical machine that incorporates a pressurized refrigerant gas in a sealed system. ONLY trained and qualified service personnel are authorized to install or service this equipment. Without proper training and knowledge of such equipment, any attemp...
Page 5 - II. Electrical Connections
2 Situate the pool heat pump carefully to minimize installation costs while providing maximum efficiency of operation, and to allow adequate service access, as follows: • For unrestricted air intake and service access, position each side of the unit at least 1 ft from walls, pipes and other obstruct...
Page 6 - III. Water Connections; WATER IN; IV. Controls and Indicator Lamps; Water Pressure Switch
3 III. Water Connections The heat pump inlet and outlet connections are NOT interchangeable. They must be connected as instructed below. 1. Connect the heat pump in the return water line between the filter and the pool. See page 10, Plumbing Diagrams. 2. Connect the filter outlet to the fitting mark...
Page 8 - Seasonal Start-Up or Annual Check; Remote
5 NOTE: The heat pump will be OFF when the Remote position is selected on the Pool/Spa selector switch and there is no remote control system attached. 4. Allow the heat pump to operate for a few minutes to stabilize operating pressures and to allow various component temperatures to normalize. 5. Ver...
Page 9 - VII. Freeze Protection; Continuous Pump Operation; must
6 VII. Freeze Protection If the heat pump is installed in a location subject to freezing conditions, it is important to protect the water circuit from freezing, just as should be done for the pump and filter. System Drain-Down 1. Turn the heat pump circuit breaker or disconnect switch to OFF. 2. Fro...
Page 11 - B. UNIT IS NOT RUNNING; Verify that the breaker is set and; Water Flow; C. CONDENSATION SEEMS EXCESSIVE; not; X. Service Call Verification; first; Power
8 B. UNIT IS NOT RUNNING • Is the control panel Power lamp ON? If not, the circuit breaker may be shut OFF or tripped. Reset the breaker by switching it OFF, then back ON. Verify that the breaker is set and operating properly before calling for service. • Are the thermostat setting and the Pool/Spa ...
Page 12 - Plumbing Diagrams
9 Plumbing Diagrams For systems with pumps of less than 2 HP (under 80 gpm), no external bypass is required. Connections are 2-inch unions. Plumb the heat pump after the filter and before any chlorinators. Water In (from pool) Water Out (to pool) Filter For systems with pumps of 2 HP or greater (ove...