Powerware 5075 kVA - Manuals
Powerware 5075 kVA – Manual in PDF format online.
Manuals:
Manual Powerware 5075 kVA
Summary
ii Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 ------------------------------------------------------------------------ ------------------------------------------------------------------------ ---------------------------------- IMPORTANT SAFETY ...
iii Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Table of Contents Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using This Manual 3 . . . . . . . . . . . . . . . ...
iv Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Section II Operation 37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Understanding UPS Operation 39 . . . . . . . . . . . . . . . . . . . . . . . . ....
vii Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 List of Figures Figure 1. Powerware BPIII Harsh Environment UPS System 2 . . . . . . . . . Figure 2. Cabinet as Shipped, with Outer Packaging and Pallet 10 . . . . . . Figure 3. Removing Front an...
1 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Introduction Powerware BPIII online power protection can be utilized to prevent loss of valuable electronic information, minimize equipment downtime, and/or minimize the adverse effect on equipment...
3 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Using This Manual This manual describes the Powerware BPIII HE UPS installation, operation and routine maintenance. The information in this manual is divided into the sections and chapters listed. ...
4 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 • Chapter 13 -- Serial Communications -- describes the serial communications features of the UPS system. • Chapter 14 -- Remote Notification -- contains instructions for using the remote notification...
5 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Safety Considerations The UPS and Environmental cabinets are designed for industrial applications in harsh environments. However, the UPS system is a sophisticated power system and should be handle...
6 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 This Page Intentionally Left Blank.
9 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Getting Started The Harsh Environment (HE) UPS system is shipped as two separate cabinets (UPS Cabinet and Environmental Cabinet). Each cabinet is shipped on a wood/foam and steel pallet. Use a for...
10 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Environment Considerations The UPS system must be installed on a sealed concrete floor. WARNING:Installation should be performed by qualified personnel. Inspecting and Unpacking Each Cabinet The fir...
11 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 2. Use a forklift or other material handling equipment to move the cabinets to a convenient unpacking area. Insert the forklift jacks between the foam cushions on the bottom of the unit. CAUTION: ...
12 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 FRONT SIDE FOAM SUPPORT SUPPORT 1 2 1 2 2 2 JACKING BOLT FLOOR PROTECTOR 1 2 DOOR CUSHION Figure 3. Removing Front and Rear Supports WARNING: Cabinet may fall. Do not loosen hardware attaching the s...
13 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing the Harsh Environment UPS System After the UPS system is unpacked and moved to the final installation location, the UPS and Environmental Cabinets are ready to be joined. Once the cabin...
14 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 WARNING:Installation should be performed by qualified personnel. Note the following important information while installing the UPS: • Dimensions in this manual are provided in millimeters and inches...
15 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Grounding Joined Cabinets Open the door of each cabinet. Locate the grounding stud at the front/side of each frame. Remove the top nut, lock washer, and flat washer from each stud (if attached, se...
16 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Installing UPS Internal Power and Control Wiring NOTE: The cables used in steps 2 through 12 are coiled inside the Environmental cabinet and are attached at the factory to the terminals inside this ...
17 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing UPS External Wiring 1. Install rectifier, bypass, and battery input power wiring to terminals in the Environmental cabinet. Refer to Drawings 164201261 --- 1 and 164201261 --- 4 in Appe...
18 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Completing the Installation Checklist The final step in installing the UPS system is completing the following Installation Checklist. This checklist ensures that all hardware, cables, and other equi...
19 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installation Checklist - All packing materials and restraints have been removed from each cabinet. - Each cabinet in the UPS system is placed in its installed location. - All cabinets are bolted t...
20 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Notes
21 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing a Remote EPO Control The Remote EPO control arrives as shown in Figure 6. See Drawing 164201261 --- 7 in Appendix A for enclosure dimensions, side views, and knockout patterns. EMERGENC...
22 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Table B. Remote EPO Remote EPO switch rating is 24 VDC. 1 Amp minimum if supplied by user. NOTE: This switch must be a dedicated switch not tied into any other circuits. 4. If installing multiple Re...
23 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing a Remote Monitor Panel As an option, a Remote Monitor Panels (RMPs) can be installed to monitor the operation of the UPS system from virtually any location within the facility, up to 50...
26 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 (ON COMMUNICATIONS PANEL OF THE UPS) DB --- 9 CONNECTOR TB1 TB2 Figure 9. Wiring an RMP to the UPS 4. Connect RMP wiring to the terminal block using terminations shown in Table D. Table D. RMP Wire ...
29 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing a Relay Interface Module The optional Relay Interface Module (RIM) uses relay contact closures to indicate the operating status and alarm condition of the UPS system. The module uses an...
32 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 4. Connect RIM wiring to the terminal block using the terminations shown in Table E. 5. Contact your local field service office for verification and testing of the RIM and its connections prior to m...
33 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Installing a Supervisory Contact Module The optional Supervisory Contact Module (SCM) as shown in Figure 13 provides contacts for monitoring UPS status. A maximum of two monitoring accessories (RM...
34 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Before installing an RMP, be sure you have prepared the UPS according to the instructions in Chapter 2. To install a Supervisory Contact Module: 1. Securely mount the SCM. 2. Install wiring from the...
35 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 (ON COMMUNICATIONS PANEL OF THE UPS) DB --- 9 CONNECTOR TB1 TB2 Figure 15. Wiring an SCM to the UPS 4. Connect the SCM wiring to the terminal block using the terminations shown in Table F. 5. Cont...
39 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Understanding UPS Operation Your UPS functions automatically to supply AC electrical power to your critical load. The UPS always operates in one of four modes: • In Normal mode, the critical load ...
40 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Looking Inside the UPS The Powerware BPIII HE is a continuous duty, solid-state UPS that supports the following equipment: process control, data processing, and telecommunications/PBX. The Powerware...
41 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Normal Mode In Normal mode, utility AC power is supplied to the rectifier. The rectifier supplies DC power to the inverter, which then supplies the critical load with AC power. The rectifier also ...
42 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Bypass Mode The UPS automatically switches to Bypass mode if it detects an overload, load fault, or internal failure. The bypass source supplies the commercial AC power to the load through an intern...
43 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Battery Mode The UPS transfers to Battery mode automatically if a utility power outage occurs, or if the utility power does not conform to specified parameters. In Battery mode, the battery, throu...
44 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Maintenance Bypass Mode The UPS can be manually switched to Maintenance Bypass mode allowing the UPS to be electrically isolated from the critical load. The bypass source supplies the commercial AC ...
45 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Monitoring and Controlling UPS Operation After you start the UPS, operator intervention is unnecessary except for periodic checks of the UPS status. Manual operation is required only during routin...
47 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Controls and Features UPS Controls The UPS has three primary control areas as described in the following paragraphs. Control Panel The Control Panel on the front of the UPS (see Figure 22) contain...
48 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Emergency Power Off An EMERGENCY POWER OFF pushbutton is provided for situations where you must immediately remove all power to your critical load. The pushbutton is located on the Monitor Panel for...
49 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Safety Considerations The UPS enclosures are designed for industrial or computer room applications, and contain safety shields behind the doors. However, the UPS is a sophisticated power system an...
50 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Symbols, Controls, and Indicators These symbols may appear on your UPS system or on labels inside the UPS. They are accepted by most international safety agents. Everyone in your organization who wo...
51 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Using the Monitor Panel This chapter describes the Monitor Panel and how to monitor and control UPS operation. The Monitor Panel is a black rectangular area on the front of the UPS (see Figure 23)...
52 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 The Monitor Panel contains: 1. A flat liquid crystal display (LCD) screen. 2. A horizontal row of pushbuttons. 3. A vertical column of backlit status indicators. 4. A red EMERGENCY POWER OFF pushbut...
53 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 D The currently selected option is highlighted in the menu box. Press the and pushbuttons to move the highlight up or down. The data in the information area ( G ) changes accordingly. E The menu b...
54 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Reading the Status Indicators The six lights on the left side of the monitor panel are status indicators . They are backlit by colored light emitting diode (LED) lamps, and work in conjunction with ...
55 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Using the Menu Options The UPS menus allow you to display data in the information area to help you monitor and control UPS operation. The following menus and options are available: • Meters Displa...
56 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Select Load Amps from the Meters menu to see a real-time bar graph of the output current of the UPS. The graph shows the current for each phase.Figure 26 shows the Load Amps Meters screen. Uninterru...
57 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Select History from the Events menu to display the Event History Log. The Event History Log lists up to 400 system events in chronological order, with the most recent event listed last. The end of...
58 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Select Active from the Events menu to display a listing of all system events that are currently active. The most recent system event is listed first. As events clear, they are removed from the Activ...
59 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Select Unit from the Statistics menu to display a listing of statistics about UPS operation.Figure 29 shows the Unit Statistics screen. Uninterruptible Power System UPS System NormalAlarm: None No...
60 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Select Mimic from the Graphics menu to display a real-time graphical representation of the flow of current through the UPS.Figure 30 shows the Mimic screen. Uninterruptible Power System UPS System N...
61 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Select Time from the Setup menu to display the Time Setup screen. The Time Setup screen allows you to set the internal timestamp of the UPS. The timestamp is used for logging events in the Event H...
63 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Operating the UPS This chapter describes how to start and stop the UPS and how to transfer the system to maintenance bypass. Figure 33 shows the location of the operating controls. NOTE: Before st...
64 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Using the Operating Controls Although the operating controls appear easy to use, you should read these instructions and thoroughly understand how the controls work before attempting to use them. Ref...
66 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Operation The following sections describe how to operate the controls to start, stop, or change the operating mode of the UPS. To Place the UPS in Normal Mode: 1. Close BIB circuit breaker. 2. Close...
67 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 To Start the UPS in Bypass Mode: If the power processing unit (PPU) of the UPS is not available and you need to energize your critical load right away, you can energize your critical load without ...
68 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 To Cold Start the UPS from Battery (No AC Input Power): To start the UPS system when commercial power is not available, perform the following procedure: 1. Ensure the feeder breaker is open (no inpu...
70 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Using the EMERGENCY POWER OFF Pushbutton Emergency Power Off is initiated by the covered, red EMERGENCY POWER OFF pushbutton on the Monitor Panel. This pushbutton is protected by a clear plastic shi...
71 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Using Features and Options The many standard features of your UPS provide consistent, economical, and dependable power protection. In addition, you can add available options and accessories to enh...
73 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Remote Monitor Panel As an option, you can install Remote Monitor Panels (RMPs) to monitor the operation of the UPS system from virtually any location within your facility, up to 500 feet from the...
75 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Relay Interface Module An optional Relay Interface Module (RIM) uses relay contact closures to indicate the operating status and alarm condition of the UPS system. A maximum of two monitoring acce...
76 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Supervisory Contact Module An optional Supervisory Contact Module (SCM) establishes an interface between the UPS manufacturer’s equipment and the customer’s monitor. This interface allows the custom...
77 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Responding to System Events When the UPS system is running in Normal mode, it continually monitors itself and the incoming utility power. In Battery or Bypass modes, the UPS may issue alarms to le...
78 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 System Event Messages When a system event occurs, a message is added to the Event History Log. A message may also appear on the Monitor Panel of the UPS. The Event History Log contains all system ev...
81 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 RECTIFIER NOTICES Input AC Over VoltageInput AC Under VoltageInput Over FrequencyInput Under FrequencyPower Supply Over VoltagePower Supply Under VoltageInput TransientDC Voltage LowDC Voltage Hig...
82 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 MONITOR NOTICES Output AC Over VoltageOutput AC Under VoltageOutput Over FrequencyOutput Under FrequencyThree Wire AC Over VoltageThree Wire AC Under VoltageThree Wire Under Freq.PowerNode Network D...
83 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 CONVERTER NOTICES Converter ShutdownConverter In StartupOK To Close CB2Converter Logic Power OK CONVERTER STATUSES Converter Normal
85 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Serial Communications This chapter describes the serial communications feature of the Powerware BPIII HE UPS. One RS --- 232/RS --- 485 serial communication port and an optional RS --- 232 serial ...
86 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Locating the Communications Panel The Communications Panel inside the UPS contains two serial communications ports, one DB --- 9 and one optional DB --- 25. The ports provide a computer interface to...
87 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Connecting Equipment to a Serial Port You can connect a wide variety of terminals, printers, and computers to each port, and configure the UPS as the Data Communication Equipment (DCE). Set up the...
88 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 3 2 1 6 5 4 9 8 7 12 11 10 13 15 14 18 17 16 21 20 19 24 23 22 25 GND RS232 TXD RS232 RXD RS232 RTS RS232 CTS RS232 DSR RTN +12V NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT US...
89 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Configuring the Serial Ports You must configure the port for communications using the LCD screen and pushbuttons on the UPS Monitor Panel. Select Port 1 or Port 2 (optional) from the Setup menu to...
91 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Data/Stop The data size and stop bits of the equipment connected to this port. These settings determine the number of bits transmitted per ASCII character. The data size and stop bits you specify ...
92 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Terminal Mode In this mode, system events are continually logged through the serial port to the device connected to the port. Port 2 operates by default in Terminal mode. The printed log entries con...
93 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Entire Log (Ctrl + P) This key sequence prints the entire Event History Log of the UPS at the time the data is requested. The printout begins with the oldest alarm entry in the queue and ends with...
94 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Meters Printout (Ctrl + M) This key sequence prints the current readings of the UPS system meters. The Input area shows the phase-to-phase voltage, frequency, and phase current of the incoming utili...
95 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Battery Test Printout (Ctrl + B) This key sequence prints the Battery Test Log. The log consists of a history of the last 30 battery tests that were run and the results of those tests. The most re...
96 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 System Configuration The System Configuration mode allows you to modify special functions in your UPS. These functions include programming of building alarms, customizing building alarm messages, ad...
97 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Enable/Disable Default Functions From this menu you may either enable the building alarms for general functions or special functions such as On Generator, Go To Bypass, and Go To UPS. You may also...
98 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Customize Alarm Messages If Customize Alarm Messages is selected from the Program Building Alarm menu, you can select a custom message for a building alarm or disable a previously enabled building a...
99 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Adjust Output Voltage If Adjust Output Voltage is selected from the main menu, the following menu is displayed: Adjust Output Voltage Output Voltage Setup: 208Output Voltage Range: 197 --- 218Ente...
100 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Battery Test Setup If Battery Test Setup is selected from the main menu, the following menu is displayed: Battery Test Setup 1. Setup One-time Delayed Battery Test2. Setup Monthly Battery Test3. Se...
101 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Modify Low Battery Time This menu allows you to modify the low battery time warning. When selected, the following menu will be displayed: Modify Low Battery TimeLow Battery Time (Minutes): 004Ent...
103 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Optional Remote Notification NOTE: The optional RS --- 232 serial communication port is required to use this feature. Remote Notification provides the user with the option of receiving alarms and...
104 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Remote Notification Features Remote Notification provides the UPS with the capability to utilize a standard off-the-shelf PC modem as a telephone interface. The features provided by this option are...
105 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Description of Operation The Remote Notification option performs three basic functions: Call Answer into Terminal mode, Call Out to a remote terminal, and Housekeeping. Remote Notification also a...
106 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 • The UPS logs a successful notify to the event log when the remote computer or modem answers and leaves an event message with the following format. nnn<space>mmm<LF><CR> where: n...
107 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Hardware Requirements The following hardware components are required to connect the Remote Notification function. • Modem: Basic external PC modem supporting the following AT commands.E0 --- Do n...
108 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Configuring the Modem The modem must be configured by the user before connecting to the UPS. In addition, the modem must be programmed with the Call Out telephone numbers in order to operate the Re...
109 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Configuring the Modem to Call a Remote Computer To configure the modem to call a remote computer, perform the following procedure: NOTE: Perform this procedure only after completing “Basic Modem ...
110 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Configuring the Modem to Call a Numeric Pager To configure the modem to call a numeric pager system, perform the following procedure. NOTE: Perform this procedure only after completing “Basic Modem...
111 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Configuring the Modem to Answer Incoming Calls To configure the modem to answer incoming calls, perform the following procedure. NOTE: Calling into the UPS does not present any type of security r...
112 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 UPS Setup Configuration Connect the modem to the UPS by connecting one end of the serial cable to the optional UPS Port 2 DB --- 25F connector and the other to the modem (refer to Chapter 13, “Seri...
117 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Maintaining the UPS System The components inside the UPS cabinet are secured to a sturdy metal frame that is supported by the UPS magnetics. This design allows authorized service personnel to rem...
118 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Performing Preventive Maintenance The UPS requires very little preventive maintenance. However, the UPS should be inspected periodically to verify that the unit is operating normally. Perform the f...
119 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Maintenance Training A basic training course, available from Powerware, gives you a competent working knowledge of UPS operation and teaches you how to perform first level corrective maintenance....
121 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Product Specifications The following sections detail the input, output and environmental specifications for the UPS system. System Models Notes Powerware BPIII HE 50 50 kVA, 40kW 50 Hz/60 Hz mode...
122 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 System Output Rectifier/Charger Capacity 135% + 6 Kw DC Filtering Ripple voltage less than 0.5% peak to peak UPS Output Capacity 100% current at 0.8 power factor Output Voltage Regulation 1% (10% t...
123 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Environmental Specifications Operating Temperature 0 to 50 ˚ C without derating. However, operating at or near 50 ˚ C will adversely affect battery life (refer to your battery specifications for ...
NOTE: Callout letter and map to drawing #164201261 --- 3 , , , DESCRIPTION: DATE: DRAWING NO: 1 of 11 INSTALLATION NOTES SHEET: REVISION: F 111503 164201261 --- 1 A --- 2 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Table A. INPUT Ratings & E...
NOTE: Callout letter and map to drawing #164201261 --- 3 , , , DESCRIPTION: DATE: DRAWING NO: 2 of 11 INSTALLATION NOTES SHEET: REVISION: F 111503 164201261 --- 1 A --- 3 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 Table B. OUTPUT Ratings &...
DESCRIPTION: DATE: DRAWING NO: 4 of 11 INSTALLATION NOTES SHEET: REVISION: B 011500 164201261 --- 1 A --- 5 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 10. Refer to Table D for internal power cable terminations and Table E for external power c...
DESCRIPTION: DATE: DRAWING NO: 5 of 11 INSTALLATION NOTES SHEET: REVISION: B 011500 164201261 --- 1 A --- 6 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Table E. External Power Cable Terminations Terminal Function Voltage Terminal Function Size o...
DESCRIPTION: DATE: DRAWING NO: 6 of 11 INSTALLATION NOTES SHEET: REVISION: E 093001 164201261 --- 1 A --- 7 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 16. Battery voltage is computed at 2 volts per cell as defined by Article 480 of the NEC. R...
DESCRIPTION: DATE: DRAWING NO: 7 of 11 INSTALLATION NOTES SHEET: REVISION: B 011500 164201261 --- 1 A --- 8 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 25. Table I lists the maximum rating for DC input circuit protection devices (circuit breaker...
TB1 BLDG ALARM 1 BLDG ALARM 4 BLDG ALARM 5 1 23456 78 9 15 10 11 14 13 12 TB2 BLDG ALARM 2 BLDG ALARM 3 BLDG ALARM 6 1 23456 78 9 15 10 11 14 13 12 RS232 RS485 ON BYPASS BATTERY CONTACTOR CLOSED RELAY 2 NO ON INV RELAY 2 NC RELAY 1 NO RELAY 1 NC BLDG ALARM 1 RTN BLDG ALARM 4 RTN BLDG ALARM 5 RTN BLD...
DESCRIPTION: DATE: DRAWING NO: INSTALLATION NOTES SHEET: REVISION: A 9 of 11 053099 164201261 --- 1 A --- 10 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 Table K. Communications Panel Inputs and Outputs TB2 Pin # Name Description 1 REMOTE EPO Con...
DESCRIPTION: DATE: DRAWING NO: 10 of 11 INSTALLATION NOTES SHEET: REVISION: A 053099 164201261 --- 1 A --- 11 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 28. Use Class 1 wiring methods (as defined by the NEC) for control wiring. Install the co...
DESCRIPTION: DATE: DRAWING NO: 11 of 11 INSTALLATION NOTES SHEET: REVISION: A 053099 164201261 --- 1 A --- 12 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 30. The Remote EPO feature opens all breakers and contactors in the UPS cabinet and isolate...
A --- 14 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 1 of 4 SHEET: REVISION: A ONELINE DRAWINGS OF UPS SYSTEM 053099 164201261 --- 3 UPS SYSTEM WITH 480/480 OR 400/400 VOLT INPUT/OUTPUT
A --- 15 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 2 of 4 SHEET: REVISION: A ONELINE DRAWINGS OF UPS SYSTEM 053099 164201261 --- 3 UPS SYSTEM WITH 480/208 VOLT INPUT/OUTPUT
A --- 16 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 3 of 4 SHEET: REVISION: A ONELINE DRAWINGS OF UPS SYSTEM 053099 164201261 --- 3 UPS SYSTEM WITH 208/208 VOLT INPUT/OUTPUT
A --- 17 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 4 of 4 SHEET: REVISION: A ONELINE DRAWINGS OF UPS SYSTEM 053099 164201261 --- 3 UPS SYSTEM WITH 600/208 VOLT INPUT/OUTPUT
A --- 18 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 1 of 2 SHEET: REVISION: D LOCATION OF UPS POWER TERMINALS 011001 164201261 --- 4 UPS CABINET ENVIRONMENTAL CABINET TB1 TB2 Bypass Input Breaker (BIB) Maintenance...
A --- 19 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 DESCRIPTION: DATE: DRAWING NO: 2 of 2 SHEET: REVISION: A LOCATION OF UPS POWER TERMINALS 053099 TB1 TB2 Ground DC Input to UPS (E4, E5) (+, --- ) Connect cables 205 and 206 AC Input to Bypas...
A --- 21 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 114.3 (4.50) 115.8 (4.56) 11.9 (0.47) 95.3 (3.75) SQUARE 88.9 (3.50) Knockout pattern typ. 5 sides TO UPS TO OTHER EQUIPMENT Dimensions are in millimeters (inches) DESCRIPTION: DATE: DRAWING...
A --- 22 Powerware BPIII Harsh Environment UPS 50--75 kV Installation and Operation 164291261 Rev. F 111503 MAX. WIRE SIZE: NO. 14 AWG MIN. WIRE SIZE: NO. 18 AWG WIRES MUST CONDUIT AND WIRING SUPPLIED BY CUSTOMER. MAX. DISTANCE BETWEEN REMOTE MONITOR AND UPS NOT TO EXCEED 500 FEET. 41.1 (1.62) 25.4 ...
A --- 23 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 19.0 (.750) 28.6 (1.12) 41.1 (1.62) EXISTING INTERNAL FLUSH MOUNT SURFACE MOUNT CONTINUES AT UPS MAX WIRE SIZE NO. 14 AWG. MIN WIRE SIZE NO. 18 AWG. Relay Interface Module 88.9 (3.50) 190.5 ...
A --- 25 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 MAX. WIRE SIZE: NO. 14 AWG MIN. WIRE SIZE: NO. 18 AWG WIRES MUST CONDUIT AND WIRING SUPPLIED BY CUSTOMER. MAX. DISTANCE BETWEEN REMOTE MONITOR AND UPS NOT TO EXCEED 500 FEET. 41.1 (1.62) 25....
W--1 Powerware BPIII Harsh Environment UPS 50--75 kVA Installation and Operatio n 164201261 Rev. F 111503 LIMITED FACTORY WARRANTY FOR THREE-PHASE POWERWARE PRODUCTS Subject to the conditions herein, Powerware ( Powerware ) warrants solely, to the original end-user, the electronics (the “Unit”), a...
Powerware Manuals
-
Powerware 5110
Manual
-
Powerware 9315 UPS
Manual
-
Powerware 9125
Manual
-
Powerware 100160 kVA
Manual
-
Powerware 700 VA
Manual
-
Powerware 10001500 VA
Manual
-
Powerware 1085
Manual
-
Powerware 9315
Manual
-
Powerware 10001100 kVA
Manual
-
Powerware 2500
Manual
-
Powerware 15 KVA
Manual
-
Powerware IPK-0318
Manual
-
Powerware 5125
Manual
-
Powerware 5115A USB
Manual
-
Powerware 5140
Manual
-
Powerware IPK-0320
Manual
-
Powerware 3115
Manual
-
Powerware 5105
Manual
-
Powerware 6000 VA
Manual
-
Powerware Powerware 9390
Manual