Page 2 - Spin Fryer I12 Cooking Computer
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 2 of 28 L22-280 Rev 1 Table of Contents: 1 Key Locations and Functions: .......................................................................................................... 4 1.1 To turn the appliance ON: _________________________...
Page 5 - To check Actual and Set temperatures:; twice
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 5 of 28 L22-280 Rev 1 1.4 To cancel a cook: Press and hold the product key to cancel a running cook. The controller displays . Press the ‘6’ button to spin the basket and the ‘0’ button to not spin the basket. If neither button is pressed after...
Page 6 - response to the boil prompt. If pressed, display will show; Boil; If control is set to
Spin Fryer I12 Cooking Computer Pitco 60149505 Page 6 of 28 L22-355 Rev 1 1 2 2 0 0 1 1.7 To perform a Boil Out operation: Normal maintenance of a fryer requires regular tank cleaning. This process involves draining the vat of oil and filling with water. Cleaning solution is added, and the control i...
Page 7 - To Set Cook Temperature:
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 7 of 28 L22-355 Rev 1 2 To Enter Programming Level 1 (for the Store Manager): Note: The factory default setting for this control does not require a password to be entered. However, the operator password requirement and value may be changed in s...
Page 8 - meaning the Hold Time is inactive.
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-355 Rev 1 Page 8 of 28 2.2 To Change a Product Key–Cook, Shake, Hold, Hold Pre-Alarm, Spin Time, and Spin Speed: For each product key, Cook, Shake, Hold, and Hold Pre-alarm times are set in this section. With display showing , continue with th...
Page 9 - Time; or continue; To Exit Level 1 programming:
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 9 of 28 L22-355 Rev 1 2.2.4 Hold Pre-Alarm Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire. To use Hold Pre-Alarm, the time value must be a non-zero value, and, must be set to a value less ...
Page 12 - Recovery Test Value:; With display showing
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-355 Rev 1 Page 12 of 28 6 3.6 Recovery Test Value: This controller maintains a record of heat up times for the appliance. A poorly running appliance will have increased recovery times stored in this display. There is no selection done here, just...
Page 13 - To Enter Programming Level 3 (for the Technician); Offset the Temperature Display:
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 13 of 28 L22-355 Rev 1 4 To Enter Programming Level 3 (for the Technician) With no cook timers running, displays will show one of the following displays: ; , or . Press the key. The left display will show . The right display will be blank. ...
Page 14 - Minimum ON and OFF Cycle Time
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-355 Rev 1 Page 14 of 28 4.3 Minimum ON and OFF Cycle Time With display showing press product key 3 . Display shows [MIN ON:nn] [MIN ON], where “nn” is the value, in seconds, of time for minimum heat pulse period. To change this value, use th...
Page 16 - Factory default value is ON.
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-355 Rev 1 Page 16 of 28 8 4.6 Ready Level With display showing press product key 6. Display shows [READY nn], where “nn” is the value, in degrees below set temperature that the message is displayed. To change this value, use the product keys f...
Page 17 - This is the factory default
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 17 of 28 L22-355 Rev 1 4.8.2 Heat Demand Profile With display showing , press product key 3 . Display will show [xxxxxxx] [HEAT DEM], where xxxxxxx may be one of 6 heat control profiles listed below. 1. [GENERIC 1] for gas fired fryer appliance...
Page 19 - Factory Menu Level 4 (for the Technician); Note: Do not change this setting. Factory shipped default is OFF; Offset Temperature Display; This menu is identical to Offset Temperature Display section 4.5; Melt Cycle ON Time; This menu is identical to Melt Cycle ON Time section 4.1except
Spin Fryer I12 Cooking Computer Pitco 60149505 Page 19 of 28 L22-355 Rev 1 5 Factory Menu Level 4 (for the Technician) With no cook timers running, displays will show one of the following displays: ; , or . Press the key. The left display will show . The right display will be blank. Enter passwo...
Page 21 - Diagnostics; Function Description; Direction
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 21 of 28 L22-355 Rev 1 5.10 Spin Diagnostics The Spin Diagnostic menu is used to determine the functionality of controller outputs and inputs. By exercising each output and examining inputs, a determination can be made if an appliance problem i...
Page 22 - . For normal operations, this setting should remain OFF; More Factory Menu Entry; This menu is identical to Set Network Address section 4.8.9 except
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-355 Rev 1 Page 22 of 28 5.11 Test On/Off With display showing press product key 0 . Display shows [TEST xx], where “xx” is ON or OFF. If ON is selected, temperatures displayed by the controller are probe tip temperatures unaltered by values set ...
Page 23 - Other
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 23 of 28 L22-355 Rev 1 6 Other Displays: Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and cooking activities are suspended. This display warns operators that the vat temperature has exceeded ...
Page 25 - Mechanical
Spin Fryer I12 Cooking Computer Pitco P/N 6049505 L22-280 Rev 1 25 of 28 7 Mechanical Dimensions:
Page 26 - Electrical Connections at LEFT and RIGHT connectors):; As viewed from the rear of the control.
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-280 Rev 1 Page 26 of 28 8 Electrical Connections at LEFT and RIGHT connectors): As viewed from the rear of the control. J1(Left) Inputs Type Nominal Notes: 1 ACH PW R 24VAC 24VAC +20% -15% 50/60Hz. 2 ACN PW R 24VACN 24VAC Return. 3 PROBE+ 4 PROB...
Page 27 - Probe Resistance Chart:
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 Page 27 of 28 L22-280 Rev 1 9 Probe Resistance Chart: Notes: Resistance, of either probe lead, to the frame of the appliance should read as “open’ on the meter. Typically this is 1Meg ohms or more. °C = 5/9 (°F-32) °F = (9/5 * °C) +32 Probe Temp (°F...
Page 28 - listed
Spin Fryer I12 Cooking Computer Pitco P/N 60149505 L22-280 Rev 1 Page 28 of 28 In the event of problems with or questions about your order, please contact the Pitco Frialator factory at (603) 225-6684 World Wide www.pitco.com In the event of problems with or questions about your equipment, please co...