Page 2 - THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE; FOR YOUR SAFETY
L20-258-UK Rev.01 8/16/04 THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE FOR YOUR SAFETY DO NOT store or use gasoline or otherflammable vapors or liquids in thevicinity of this or any other appliance. WARNING Improper installation, alteration, serviceor maintenance can cause propertydamage, injur...
Page 3 - Table of Contents; Section; Installation; Assembly and Leveling; Operation; Filling the Tank; Cleaning and Maintenance; Daily Cleaning; Troubleshooting
L20-258-UK Rev.01 8/16/04 Table of Contents Section Page Installation Checking your new Pitco Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Assembly and Leveling Leg and Caster Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation C...
Page 4 - INSTALLATION; two of its casters or legs, or pull the appliance by the splash back.
INSTALLATION L20-258-UK Rev.01 8/16/04 1 CHECKING YOUR NEW PITCO APPLIANCE Your new Pitco appliance has been carefully packed into one crate. Every effort has been made to ensure thatit is delivered to you in perfect condition. As you unpack your new appliance, inspect each of the pieces fordamage. ...
Page 6 - Types of Fire Extinguishers and Detection Equipment; “Oil Level” mark stamped on the tank.; WARNING
INSTALLATION L20-258-UK Rev.01 8/16/04 3 Types of Fire Extinguishers and Detection Equipment Topic UL Document National Fuel Gas Code Document CO 2 Type Extinguishers ANSI/UL 154 ANSI/NFPA 12 Dry Chemical Type Extinguishers ANSI/UL 299 ANSI/NFPA 17 Water Type Extinguishers ANSI/UL 626 ANSI/NFPA 13 F...
Page 7 - OPERATION; FILLING THE TANK; will cause a fire and could result in personal injury.; DO NOT; OPERATING INSTRUCTIONS
OPERATION 4 L20-258-UK Rev.01 8/16/04 ELEMENTS ELEMENTS SOLID SHORTENING / OIL EXCESSIVE AIR GAPS ELEMENTS SOLID SHORTENING / OIL FILLING THE TANK Both liquid and solid shortening/oil can be used in this appliance, but liquid is preferred. If solidshortening/oil is used it is recommended that you me...
Page 9 - FILTERING INSTRUCTIONS; Filter option is not available on Model E500D; DO NOT run the filter without a filter paper on the pickup assembly.
OPERATION 6 L20-258-UK Rev.01 8/16/04 Appliance Shut-down For models with electric thermostat option refer to the following instructions. a. Turn the temperature control knob (thermostat) to the OFF ( O )position. b. Place the ON/OFF (I/O) rocker switch to the OFF ( O ) position. The light on the sw...
Page 11 - CLEANING and MAINTENANCE; DAILY CLEANING; Filter Pan and Filter Pickup Assembly Cleaning; Boil Out Procedure
CLEANING and MAINTENANCE 8 L20-258-UK Rev.01 8/16/04 DAILY CLEANING Your appliance should be cleaned every day to maintain peak performance, proper sanitation and appearance.Perform the following procedures daily. a. Wipe up any shortening/oil that spills onto the exterior of the appliance. This sho...
Page 12 - Filter System Cleaning
CLEANING and MAINTENANCE L20-258-UK Rev.01 8/16/04 9 WARNING At operating temperatures, the shortening/oil in the appliance is VERY HOT and can cause severe burns. Do not let the hot shortening/oil touch your skin or clothing. ALWAYS wear insulated, shortening/oil proof gloves, protective clothing a...
Page 13 - Thermostat Calibration Check; NOTICE; CAUTION; Thermostat Calibration; NOTE
CLEANING and MAINTENANCE 10 L20-258-UK Rev.01 8/16/04 Thermostat Calibration Check NOTICE Thermostat calibration requires that the temperature of the appliance be raised above boiling. If you have water in the tank you will need to drain it, dry it and fill it with shortening/oil. Follow the filling...
Page 14 - TROUBLE SHOOTING; TROUBLESHOOTING
TROUBLE SHOOTING L20-258-UK Rev.01 8/16/04 11 TROUBLESHOOTING Should there be a problem with your appliance, use the following tables to isolate possible faults before callingyour Authorized Service Agent. Check these items before calling your Authorized Service Company. ITEM TO CHECK HOW TO CHECK P...