Summary

Page 2 - TECHNICAL CHANGES

TECHNICAL CHANGES 2 1 MUH-A07YV- ➔ MUH-GA20VB- 1. Indication of capacity has been changed. (BTU base ➔ kw) 2. Dimension of outdoor unit has been changed. (780W o 540H o 255D ➔ 800W o 550H o 285D) 3. Stop valve cover has been added.4. Outdoor fan motor has been changed. (RC6V20-AB ➔ RA6V21-AD) 5. Out...

Page 3 - INFORMATION FOR THE AIR CONDITIONER WITH R410A REFRIGERANT

3 Refrigeration oil Refrigerant New refrigerant R410A HFC-32: HFC-125 (50%:50%) Pseudo-azeotropic refrigerant Not included A1/A1 72.6 -51.4 1.557 64 Non combustible 0 1730 From liquid phase in cylinder Possible Incompatible oil Non Non Previous refrigerant R22 R22 (100%) Single refrigerant Included ...

Page 4 - Can R22 tools be used?; Tools dedicated for the air conditioner with R410A refrigerant

4 2.Refrigerant piping 1 SpecificationsUse the refrigerant pipes that meet the following specifications. • Use a copper pipe or a copper-alloy seamless pipe with a thickness of 0.8 mm. Never use any pipe with a thickness less than 0.8mm, as the pressure resistance is insufficient. Wallthickness Outs...